Igor Pušnik

ORCID: 0000-0003-1438-5178
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Calibration and Measurement Techniques
  • Advanced Sensor Technologies Research
  • Sensor Technology and Measurement Systems
  • Scientific Measurement and Uncertainty Evaluation
  • Infrared Thermography in Medicine
  • Thermoregulation and physiological responses
  • Radiative Heat Transfer Studies
  • Climate Change and Health Impacts
  • Thermography and Photoacoustic Techniques
  • Infrared Target Detection Methodologies
  • Atmospheric Ozone and Climate
  • Thermal Regulation in Medicine
  • Wireless Sensor Networks for Data Analysis
  • Bee Products Chemical Analysis
  • Experimental Learning in Engineering
  • Spacecraft Design and Technology
  • Hemodynamic Monitoring and Therapy
  • Effects of Environmental Stressors on Livestock
  • Induction Heating and Inverter Technology
  • Animal Behavior and Welfare Studies
  • Delphi Technique in Research
  • Date Palm Research Studies
  • Insect Pheromone Research and Control
  • Bluetooth and Wireless Communication Technologies
  • Milk Quality and Mastitis in Dairy Cows

University of Ljubljana
2013-2025

Slovenian Institute of Quality and Metrology
2004-2025

Metrology Institute of the Republic of Slovenia
2011-2017

Slovenský Metrologický Ústav
2002

Growing concern regarding animal welfare has increased the need for reliable methods of assessing health status without stress during commercial farm practice. Measuring body temperature with a thermal imaging camera is one possible stress-free technique since it non-contact and non-invasive. The first objective this study was to determine best anatomical site in healthy pigs measuring high spatial resolution that gives results equivalent or related temperatures measured rectum. second...

10.1016/j.compag.2021.106656 article EN cc-by Computers and Electronics in Agriculture 2022-01-08

The objective of the study was to ascertain potential infrared thermal imaging (IRT) detect development clinical mastitis at an early stage. carried out on a one-site small pig farm with 80 breeding sows (crossbreed Landrace × Yorkshire) that had history high incidence MMA. udder-skin temperatures were measured using high-quality IRT camera (FLIR T650sc), in accordance measurement protocol (including calibration and corrections), uncertainty ±0.5∘C. This improves upon previous research by...

10.3390/agriculture15070697 article EN cc-by Agriculture 2025-03-25

Abstract Measurement of human body temperature seems rather trivial until we become parents or medical professionals. If use different thermometers, which are used at sites, inevitably come across to measurement results. Then ask ourselves result is the right one. The answer far from because there a few dilemmas in temperature. To none these exists straight answer. article describes and thermometers for its measurement. Presented also calibration results certain clinical radiation their...

10.1080/10739140903149061 article EN Instrumentation Science & Technology 2009-08-10

10.1007/s10765-011-0932-z article EN International Journal of Thermophysics 2011-01-01

Infrared ear thermometers (IRETs) are extensively used for measuring the temperature of a human body. For accurate measurements with IRETs they have to be calibrated regularly an appropriate and traceable calibration system. Such systems neither widely available nor there many competent (accredited) laboratories which can provide traceability IRETs. This paper describes some important influential parameters in use IRETs, were observed during extensive research on not been reported literature...

10.1088/0967-3334/26/6/016 article EN Physiological Measurement 2005-11-07

Thermal imagers are becoming widely used instruments for noncontact absolute temperature measurements as opposed to previous practice when they were mostly measure differences. To assure accurate and reliable measurements, a calibration procedure including evaluation of the thermal imager entire field view (FOV) is needed. The challenge was construct large aperture blackbody, covering complete FOV having better stability non-uniformity than sensitivity imager. blackbody bath designed on...

10.1088/0957-0233/24/2/025001 article EN Measurement Science and Technology 2012-12-21

In numerous applications, including current body temperature monitoring in viral pandemic management, thermal imaging cameras are used for quantitative measurements. These require determination of the measurement accuracy (error) and its traceability (measurement uncertainty). Within error estimation, size-of-source effect (SSE) is an important source. The SSE relation between physical size a target instrument’s nominal size. This study presents direct evaluation due to SSE. A stable uniform...

10.3390/s21020607 article EN cc-by Sensors 2021-01-16

The paper describes a system for the determination of size-of-source effect (SSE) radiation thermometers with direct reading temperature, which form majority commercial thermometers. Optics in every thermometer (RT) gathers from larger area than is defined by nominal target size. Thus, measured temperature more or less dependent on available area. Every suffers SSE. We developed system, based water-cooled holder, measuring SSE method. could be placed front any blackbody. Manufacturing such...

10.1088/0957-0233/17/6/007 article EN Measurement Science and Technology 2006-05-02

There is an incorrect value in the print issue (volume 25, 3, June 2004). On page 703, 12 lines from bottom, text 'we get error of 3.7 °C' should read as 0.3 °C'. This inaccuracy also appeared full-text online PDF file but was corrected on 28 2004.

10.1088/0967-3334/25/5/c01 article EN Physiological Measurement 2004-08-09

This paper presents a temperature evaluation method by means of high-speed, visible light digital camera visualization and its application to the mineral wool production process. The proposed adequately resolves temperature-related requirements in significantly improves spatial temporal resolution measured fields. Additionally, it is very cost effective comparison with other non-contact field measurement methods, such as infrared thermometry. Using for temperatures between 800°C 1500°C,...

10.1364/ao.54.007978 article EN Applied Optics 2015-09-08

Clinical thermometers in intensive care units are used for the continuous measurement of body temperature. This study describes a procedure dynamic uncertainty evaluation order to examine requirements clinical thermometer properties standards and recommendations. In this thermistors were as temperature sensors, transient measurements performed water air data processed investigation properties. The mathematically modelled. A Monte Carlo method was implemented evaluation. analysed static...

10.1088/0957-0233/27/9/095001 article EN Measurement Science and Technology 2016-07-13

Current process of calibrating radiation thermometers, including thermal imagers, relies on measurement comparison with the temperature a black body at set distance. Over time, errors have been detected in calibrations some which were correlated moisture levels. In this study, effects atmospheric air transmission evaluated by means simulations using best available resources corresponding datasets. Sources spectral transmissivity listed, and data was obtained from HITRAN molecular absorption...

10.3390/s21165509 article EN cc-by Sensors 2021-08-16

The objective of this paper is to elaborate new elements related metrological analysis in the field testing, such as measurement uncertainty and traceability. Until now international standard ISO 45001 did not explicitly require specifications area testing an extent newly implemented ISO/IEC 17025. Therefore several additional steps should be performed specifying results, especially concerning performance other conformity assessment activities.

10.1088/0957-0233/13/4/320 article EN Measurement Science and Technology 2002-03-11

10.1007/s10765-017-2234-6 article EN International Journal of Thermophysics 2017-05-09

The objective of the paper is to discuss automation a precision calibration laboratory in view achieving maximal quality metrological performance. Besides measurement equipment for ease operation, communication and data processing, basic emphasis given reliability flexibility, possibility minimal uncertainty equipment. Several software design guidelines are discussed case high-precision temperature laboratory.

10.1109/19.850401 article EN IEEE Transactions on Instrumentation and Measurement 2000-06-01

In this paper an automated system for the evaluation of climatic chambers is presented. Besides automation, a basic emphasis given to reliability operation, flexibility and possibility achieving minimal uncertainty application. The developed completely satisfy all standards requirements concerning and/or calibration in laboratory as well on site.

10.1109/19.982952 article EN IEEE Transactions on Instrumentation and Measurement 2001-01-01

Abstract Accurate and repeatable spatial positioning of measurement equipment is required in many laboratory experiments procedures. Although such mechanical manipulation can often be performed manually, by using special as different tripods, an automated system offers several advantages, higher accuracy repeatability, reduced operator workload, possibility to implement more complex Many adequate systems are commercially available, but our aim was produce a high quality, low cost, oriented...

10.1080/10739140903253004 article EN Instrumentation Science & Technology 2009-09-25

In this paper, the automation of calibration liquid-in-glass thermometers (LiGTs) is discussed. Temperature readings are taken automatically with use a measuring system that consists standard setup, video camera and illumination, an image acquisition module computer executes algorithm for processing analysis. Once reading temperature extracted from acquired image, value can be passed to any other data program, which includes comparison values reference thermometer determination correction...

10.1109/19.982951 article EN IEEE Transactions on Instrumentation and Measurement 2001-01-01

Abstract According to requirements of the ISO/IEC 17025:2005 standard, environmental conditions while calibrating are monitored and stated in calibration certificate. In this paper we present an experiment for evaluation behavior our on-site measuring equipment regarding its specifications suitability these typical work. We built a setup determining temperature relative humidity dependence equipment. Main units were placed climatic chamber, sensors into ice bath generator, respectively. The...

10.1520/jte101866 article EN Journal of Testing and Evaluation 2008-11-01

The objective of this paper is to analyze major error sources in the process simultaneous calibration a large number thermocouples (TCs). main reason for occurrence additional when TCs are simultaneously calibrated due inhomogeneity effects and characteristics particular measuring setup. need such calibrations fact that, often, relatively low-cost but traceably needed monitoring purposes measurements temperature profiles applications, as evaluation humidity chambers, wind channels, tunnel...

10.1109/tim.2002.806009 article EN IEEE Transactions on Instrumentation and Measurement 2002-10-01
Coming Soon ...