Joris Jaspers

ORCID: 0000-0003-1957-631X
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Surgical Simulation and Training
  • Soft Robotics and Applications
  • Quality and Safety in Healthcare
  • ECG Monitoring and Analysis
  • Cardiac Imaging and Diagnostics
  • Anatomy and Medical Technology
  • Advanced X-ray and CT Imaging
  • Reconstructive Surgery and Microvascular Techniques
  • Total Knee Arthroplasty Outcomes
  • Augmented Reality Applications
  • Electronic Health Records Systems
  • Nuclear reactor physics and engineering
  • Nuclear Physics and Applications
  • Mobile Health and mHealth Applications
  • Cardiac, Anesthesia and Surgical Outcomes
  • Advanced MRI Techniques and Applications
  • Minimally Invasive Surgical Techniques
  • Knee injuries and reconstruction techniques
  • Artificial Intelligence in Healthcare and Education
  • Delphi Technique in Research
  • Healthcare Technology and Patient Monitoring
  • Cardiac pacing and defibrillation studies
  • Facial Trauma and Fracture Management
  • Atrial Fibrillation Management and Outcomes
  • Medical Imaging Techniques and Applications

University Medical Center Utrecht
2014-2024

Utrecht University
2012-2024

Amsterdam UMC Location University of Amsterdam
2000-2007

University of Amsterdam
2001-2004

The Netherlands Cancer Institute
2001-2004

Academic Center for Dentistry Amsterdam
2004

Slovak Academy of Sciences
2000

Abstract Aims Many portable electrocardiogram (ECG) devices have been developed to monitor patients at home, but the majority of these are single lead and only intended for rhythm disorders. We miniECG, a smartphone-sized device with four dry electrodes capable recording high-quality multi-lead ECG by placing on chest. The aim our study was investigate ability miniECG detect occlusive myocardial infarction (OMI) in chest pain. Methods results Patients presenting acute pain emergency...

10.1093/ehjdh/ztae002 article EN cc-by-nc European Heart Journal - Digital Health 2024-01-17

Background Electrocardiograms (ECGs) are used by physicians to record, monitor, and diagnose the electrical activity of heart. Recent technological advances have allowed ECG devices move out clinic into home environment. There is a great variety mobile with capabilities be in environments. Objective This scoping review aimed provide comprehensive overview current landscape devices, including technology used, intended clinical use, available evidence. Methods We conducted identify studies...

10.2196/44003 article EN cc-by JMIR Cardio 2023-06-06

With the growing shortage of nurses, labor-saving technology has become more important. In health care practice, however, fit with innovations is not easy. The aim this study to analyze development a mobile input device for electronic medical records (MEMR), potentially application supported by that failed meet needs nurses after development. case study, we used an axiomatic design framework as evaluation tool visualize mismatches between customer and parameters MEMR, trace these back...

10.1186/s12911-018-0726-3 article EN cc-by BMC Medical Informatics and Decision Making 2019-01-14

Strackee, Simon D. M.D.; Kroon, Frans H.M. D.M.D., Ph.D.; Spierings, Pieter T.J. M.D., M.Sc.; Jaspers, Joris E.N. M.Sc. Author Information

10.1097/01.prs.0000142766.26117.5b article EN Plastic & Reconstructive Surgery 2004-12-01

The fibula osteocutaneous free flap has become the preferred method for most cases of mandibular reconstruction after oncologic surgical ablation. To recreate parabolic form mandible, to be divided up into segments using a closed wedge osteotomy technique. number osteotomies is preferably kept minimum so that segmental periosteal circulation not compromised and also keep operating time minimum. limited creates an angular contour. aim this study was establish degree which overcorrection or...

10.1097/00006534-200112000-00010 article EN Plastic & Reconstructive Surgery 2001-12-01

Performing complex tasks in Minimally Invasive Surgery (MIS) is demanding due to a disturbed hand-eye co-ordination, the use of non-ergonomic instruments with limited degrees freedom (DOFs) and lack force feedback. Robotic telemanipulatory systems enhance surgical dexterity by providing up 7 DOFs. They allow surgeon operate an ergonomically favorable position more intuitive manipulation instruments. Commercially available robotic systems, however, are very bulky, expensive do not provide any...

10.1115/detc2004-57137 article EN 2004-01-01

Portable, smartphone-sized electrocardiography (ECG) has the potential to reduce time treatment for patients suffering acute cardiac ischemia, thereby lowering morbidity and mortality. In UMC Utrecht, a portable, smartphone-sized, multi-lead precordial ECG recording device (miniECG 1.0, Utrecht) was developed. The purpose of this study investigate ability miniECG capture ischemic changes in porcine coronary occlusion model. 8 animals, antero-septal myocardial infarction induced by 75-minute...

10.1016/j.jacadv.2023.100410 article EN cc-by-nc-nd JACC Advances 2023-07-01

During minimally invasive procedures, an assistant controls the camera and often a laparoscopic grasper. Ideally, surgeon should be able to manipulate instruments because indirect way of control complicates surgeon's observation actions disturbs eye-hand coordination. Reported replacements for are active positioners, "robots," such as Aesop EndoAssist. Because positioning is static task, Academic Medical Center has developed passive instrument (PASSIST) allow solo surgery.The PASSIST was...

10.1089/lap.2000.10.331 article EN Journal of Laparoendoscopic & Advanced Surgical Techniques 2000-12-01

Laparoscopy has important consequences for the functioning of surgeon, affecting both his/her perception and manipulation capabilities. To be able to judge aspects laparoscopic instruments, a thorough insight into surgeon is needed, realistic model operation process should starting point every new design. In addition, it efficient use observational methods gain most limitations encountered in clinical practice effect an alternative achieve simplification procedure, innovative unconventional...

10.1080/136457001753192268 article EN Minimally Invasive Therapy & Allied Technologies 2001-01-01

Performing complex tasks such as vascular anastomosis in minimally invasive surgery (MIS) is demanding due to a disturbed hand-eye co-ordination, the application of non-ergonomic instruments with limited number degrees freedom (DOFs) and lack three-dimensional perception. Robotic tele-manipulatory systems enhance surgical dexterity by providing up seven DOFs. They allow surgeon operate an ergonomically favourable position more intuitive manipulation instruments. systems, however, are very...

10.1080/13645700410032851 article EN Minimally Invasive Therapy & Allied Technologies 2004-01-01

Existing laparoscopic instrument holders do not seem to sufficiently fulfil the needs of surgeons performing minimally invasive surgery (MIS) in several respects. Therefore, we developed and tested a novel positioner close cooperation between engineers.Design requirements were established by attending interventions, interviews involving during design cycle evaluation early mock-ups prototypes.Two concepts, based on scissor- deflectable ball principle, elaborated evaluated yielding simple,...

10.3109/13645706.2015.1039547 article EN Minimally Invasive Therapy & Allied Technologies 2015-04-28

'Robotics' indicates the master-slave systems, which are currently applied to minimally invasive surgery and sometimes claimed use for teleoperation. These systems characterized by electromechanical tools providing a wrist function within body, with minimal access 8-15 mm cannulas. Opposite conventional surgery, controlling movements of master translated tip tool without mirroring variable scaling improving hand-eye coordination considerably. Only visual feedback an (stereo) endoscope is...

10.1109/icsmc.2004.1400703 article EN 2005-03-31

This study aimed to evaluate the feasibility and efficacy of a mechanical minimally invasive manipulator for endoscopic surgery. In contrast currently available motorized master-slave manipulators, this consists two purely mechanical, hand-controlled arms with joints that allow seven degrees freedom (DOF).For study, 30 medical students performed four different tasks in pelvic trainer box using either conventional needleholders or set manipulators. The exercise consisted tasks: repositioning...

10.1007/s00464-006-9038-2 article EN cc-by-nc Surgical Endoscopy 2007-02-05

Purpose The evaluation of a construction that allows the exchange circular and unilateral external fixators on same fixation pins to bone in outpatient circumstances during lengthening alignment procedures. Methods Nine children were treated with this concept. After alignment, exchanged for clinic hold position bony parts consolidation phase. Results decrease time needed use fixator treatment was considered be an improvement comfort. Conclusions concept using both combines advantages...

10.1007/s11832-010-0247-9 article EN cc-by Journal of Children s Orthopaedics 2010-03-18
Coming Soon ...