Djamel Ziane

ORCID: 0000-0003-2711-2945
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Scientific Measurement and Uncertainty Evaluation
  • Semiconductor materials and devices
  • Radioactive Decay and Measurement Techniques
  • Advancements in Semiconductor Devices and Circuit Design
  • Advanced Sensor Technologies Research
  • Silicon Carbide Semiconductor Technologies
  • Silicon and Solar Cell Technologies
  • Integrated Circuits and Semiconductor Failure Analysis
  • Semiconductor materials and interfaces
  • Multilevel Inverters and Converters
  • Advanced Measurement and Metrology Techniques
  • Advanced Memory and Neural Computing
  • Induction Heating and Inverter Technology
  • Mechatronics Education and Applications
  • Silicon Nanostructures and Photoluminescence
  • Microgrid Control and Optimization
  • Sensor Technology and Measurement Systems
  • Advanced MEMS and NEMS Technologies
  • Healthcare Systems and Practices
  • Wind Turbine Control Systems
  • Magnetic confinement fusion research
  • Scientific Research and Discoveries
  • Electric Motor Design and Analysis
  • Magnetic Bearings and Levitation Dynamics
  • Advanced DC-DC Converters

Laboratoire National de Métrologie et d'Essais
2015-2024

University of Béjaïa
2024

Institut National des Sciences Appliquées de Lyon
2004

Centre National de la Recherche Scientifique
1999-2003

Université de Reims Champagne-Ardenne
1999-2003

A determination of the Planck constant h using LNE Kibble balance in air was carried out spring 2017. Substantial improvements since 2014, chiefly related to mass standard, mechanical alignments, voltage measurements and type evaluation uncertainties, leads a value 6.626 070 41(38) × 10–34 J · s, with relative standard uncertainty 5.7 10–8.

10.1088/1681-7575/aa7882 article EN Metrologia 2017-06-09

After separate developments of the different elements with continuous characterizations and improvements, LNE watt balance has been assembled. This paper describes system in detail gives its first measurements Planck's constant h. The value determined air is h = 6.626 068 8(20) × 10−34 Js which differs relative terms by −0.05 10−7 from h90 −1.1 that 2010 CODATA adjustment standard uncertainty associated 3.1 10−7.

10.1088/0026-1394/52/2/433 article EN Metrologia 2015-04-01

Main text This report describes the second CCM key comparison of realizations kilogram definition based on fixed numerical value Planck constant, which came into force 20 May 2019. The objectives were to determine level agreement between using Kibble and joule balances x-ray crystal density (XRCD) method provide input for calculation "consensus value" kilogram. consensus serves as basis an internationally coordinated dissemination is updated after each new comparison. Its use will continue...

10.1088/0026-1394/60/1a/07003 article EN Metrologia 2023-01-01

The definition of the kilogram in International System Units (SI) is expected to be revised 2018. present kilogram, mass Prototype Kilogram (IPK), adopted 1889, would then replaced by a based on fixed numerical value Planck constant. Consultative Committee for Mass and Related Quantities has requested that, as one essential steps before redefinition, comparison realizations future realization methods, Kibble9 balances x-ray crystal density (XRCD) experiments, organized.

10.1088/1681-7575/aa9a7e article EN Metrologia 2017-11-14

This paper deals with the design of five-phase permanent magnet synchronous machines (PMSMs) exploiting third harmonic for torque generation. Through optimization stator size and rotor structure, objective functions related to mass electric losses are minimized a targeted electromagnetic power (10 kW 400 rpm) given volume. The study takes into account saturation, thermal, electrical mechanical constraints. On that note, 1D analytical magnetic model, considering existence use harmonic, is...

10.3390/machines12020117 article EN cc-by Machines 2024-02-07

This paper describes the mechanical and electrical modifications carried out on LNE watt balance to reduce noise level associated with static phase. The improvements concern home-made beam using flexure hinges as pivots of force comparator. involve source used servo-control equilibrium position during All these have led a significant improvement repeatability reproducibility results phase measurements.

10.1063/1.4964293 article EN Review of Scientific Instruments 2016-10-01

ou non, émanant des établissements d'enseignement et de recherche français étrangers, laboratoires publics privés.

10.4028/www.scientific.net/msf.457-460.1281 article FR Materials science forum 2004-06-15

Relaxation phenomena of positive charges, created in a metal–oxide–silicon capacitor by bidirectional Fowler–Nordheim electron injections under constant current, have been studied and their kinetics quantitatively characterized. After creation, charges are neutralized at current. The gate bias shift caused the neutralization process has an exponential dependence on time during relaxation irrespective stress field polarity duration. Analysis data assuming nonelectron detrapping gives capture...

10.1063/1.371719 article EN Journal of Applied Physics 1999-12-01

High electric-field stresses were performed in polycrystalline silicon gate metal-oxide-semiconductor devices (capacitors and transistors) defect generation was studied as a function of injecting electron densities for polarities different high electric fields. This work oxide thicknesses technologies. The results show that the interface states generated during injections from silicon-substrate saturate. However, they present no saturation when created gate. Our amount this asymmetry depends...

10.1088/0022-3727/32/13/301 article EN Journal of Physics D Applied Physics 1999-01-01

The value of the Planck constant h was determined in 2014 by means LNE watt balance experiment. relative standard uncertainty 31 parts 108. This first determination performed air with a 500 g mass made from XSH Alacrite. main components associated involve calibration, stability, buoyancy correction and magnetic interaction correction. combined due to is 7.2 use 2016 platinum iridium alloy significantly reduces component arising for measurement either or under vacuum. this contribution...

10.1088/0026-1394/53/4/1139 article EN Metrologia 2016-07-18

Efficient operation is a recommended factor in most of industrial applications. In this paper, an indirect matrix converter (IMC) topology developed and proposed to substitute the classical (AC/DC/AC) three phase topologies; where control strategy frequently performed with voltage source inverter (VSI). Large electrolytic capacitors are viewed as hazardous due their short lifetime compared ordinary power switches, well contribution total bulk weight converter. Matrix converters may be answer...

10.3311/ppee.22832 article EN Periodica Polytechnica Electrical Engineering and Computer Science 2024-05-27

Tunneling Fowler–Nordheim bidirectional electron injections were performed on a metal–oxide–silicon capacitor under constant voltage, and the study of generated defects behavior was investigated. It found that within oxide are same physical nature mainly composed neutral traps. The charge discharge these traps depend field polarity. At oxide–silicon interface, saturation interface state generation is maintained by alternate change stress This linked to Si−δ–H+δ or other Si−δ–A+δ polar bonds...

10.1063/1.370166 article EN Journal of Applied Physics 1999-05-01

This paper describes the main improvements on LNE Kibble balance in order to eliminate significant mechanical problems which prevent measurements under vacuum conditions: they will allow kilogram realizations some months.

10.1109/cpem49742.2020.9191832 article EN 2020-08-01

UV scanning photoluminescence spectroscopy is applied to 4H-SiC epitaxy characterization. In a first part, the technique used for triangular defects The results show that two kinds of are present. Some inclusion cubic SiC which confirmed by Raman spectroscopy. other ones consist staking faults different thicknesses acting as quantum wells. second effective lifetime profile mapped whole 50 mm using variation room temperature PL intensity versus excitation intensity.

10.1051/epjap:2004105 article EN The European Physical Journal Applied Physics 2004-07-01

Bidirectional electron injections were performed in thick and thin oxides of metal–oxide–silicon capacitors under a constant oxide electric field. Results show that dissymmetry, due to trapping near both interfaces, is accentuated when the thin. However more marked thick. Two kinds used: wet dry technologies. Wet contains relatively defects than dry. This hydrogen incorporation during oxidation process. But this difference not well marked, because boron atoms injected after process would...

10.1063/1.1334368 article EN Journal of Applied Physics 2001-01-15

Bidirectional electron injections are made on metal–oxide–silicon capacitors under constant currents or voltages. It is shown that both stresses reveal the same generation mechanism of oxide defects and consequently confirm gate/oxide interface more stress resistant than oxide/silicon interface. also created positive charge unstable during bidirectional stress. We characterize this instability by studying dielectric defect neutralization following a new procedure. Oxide field intensity...

10.1063/1.1322594 article EN Journal of Applied Physics 2000-12-01

La 26 e Conférence générale des poids et mesures (CGPM) s’est réunie à Versailles du 13 au 16 novembre 2018. Elle a rassemblé les représentants de la plupart 59 États membres Bureau international (BIPM) 43 associés.

10.1051/refdp/201962011 article FR Reflets de la physique 2019-06-01

The Planck constant h was determined in 2014 by means of the French watt balance experiment at LNE (Trappes).The relative standard uncertainty 3.1×10 -7 .This first determination performed air with a 500 g mass made from Co-based superalloy.The two main corrections are buoyancy correction order 66 mg, and magnetic interaction about 37 µg.This force appears between artifact residual field coming permanent magnet used experiment.The components associated calibration uncertainty, stability...

10.1051/metrology/20150018001 article EN cc-by 16th International Congress of Metrology 2015-01-01
Coming Soon ...