Jiawen Li

ORCID: 0000-0003-3698-602X
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • High voltage insulation and dielectric phenomena
  • Power Transformer Diagnostics and Insulation
  • Pharmacological Effects of Natural Compounds
  • Elevator Systems and Control
  • Tree Root and Stability Studies
  • Machine Fault Diagnosis Techniques
  • Civil and Geotechnical Engineering Research
  • Advanced Battery Technologies Research
  • Plant Physiology and Cultivation Studies
  • Electromagnetic Launch and Propulsion Technology
  • Hydraulic and Pneumatic Systems
  • Geotechnical Engineering and Underground Structures
  • Cavitation Phenomena in Pumps
  • Power Systems and Technologies
  • Microgrid Control and Optimization
  • Phytochemistry and biological activity of medicinal plants
  • Phytochemistry and Bioactivity Studies
  • Smart Grid Energy Management

Harbin Medical University
2024

Northeast Electric Power University
2021-2024

Beihang University
2011

North China University of Technology
2011

East China Jiaotong University
2011

Partial discharge (PD) fault diagnosis is of great importance for ensuring the safe and stable operation power transformers. To address issues low accuracy in traditional PD diagnostic methods, this paper proposes a novel method transformer diagnosis. It incorporates approximate entropy (ApEn) symplectic geometry mode decomposition (SGMD) into optimized bidirectional long short-term memory (BILSTM) neural network. This extracts dominant features employing SGMD ApEn. Meanwhile, it improves...

10.3390/e26070551 article EN cc-by Entropy 2024-06-27

With the increasing building energy consumption, integrated photovoltaic has emerged. However, this method problems such as low absorption rate and large load peak–valley difference. For reason, authors have constructed a photovoltaic-phase change material system considering demand response. Under response at time of use, was powered by power generation. The thermostatically controlled inside buildings satisfied jointly phase storage air conditioning. can run offline or connected to grid...

10.1049/esi2.12013 article EN cc-by-nc-nd IET Energy Systems Integration 2021-04-14

Abstract Insulation deterioration, which is mainly caused by partial discharge (PD) occurring inside power transformers, one of the prime reasons to cause transformer faults. Therefore, an effective diagnosis PD crucial ensure safe and stable operation transformers. To extract more features that characterise transformers signals enhance recognition accuracy, a novel fault model based on improved adaptive local iterative filtering (ALIF) bidirectional long short‐term memory (BILSTM) neural...

10.1049/elp2.12471 article EN cc-by-nc-nd IET Electric Power Applications 2024-07-15

In recent years, pipeline transportation technology has been rapidly developing in China. A large number of new gas (coal gas) pipelines, sewage and running water pipelines must pass beneath existing roads, railways or buildings. Due to the local conditions restrictions for construction, open cut digging often cannot be used, only trenchless methods may employed. order further reduce effect construction on recently developed grid jacking employed, which minimizes impact structures. This...

10.1061/41202(423)120 article EN 2011-10-07
Coming Soon ...