Manfred Staat

ORCID: 0000-0003-4363-6570
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Fatigue and fracture mechanics
  • Probabilistic and Robust Engineering Design
  • Elasticity and Material Modeling
  • High Temperature Alloys and Creep
  • Pelvic and Acetabular Injuries
  • Pelvic floor disorders treatments
  • Metallurgy and Material Forming
  • Shoulder Injury and Treatment
  • Cardiac electrophysiology and arrhythmias
  • Hernia repair and management
  • Orthopedic Surgery and Rehabilitation
  • Elbow and Forearm Trauma Treatment
  • Neuroscience and Neural Engineering
  • Shoulder and Clavicle Injuries
  • Structural Health Monitoring Techniques
  • Winter Sports Injuries and Performance
  • Pluripotent Stem Cells Research
  • Metal Forming Simulation Techniques
  • Cryospheric studies and observations
  • Anorectal Disease Treatments and Outcomes
  • Structural Response to Dynamic Loads
  • Structural Integrity and Reliability Analysis
  • Mechanical Failure Analysis and Simulation
  • Numerical methods in engineering
  • Elasticity and Wave Propagation

FH Aachen
2016-2025

University of Duisburg-Essen
2016

Forschungszentrum Jülich
1996-2016

RWTH Aachen University
1985-2013

This work presents a new model for the shakedown analysis of Kirchhoff plates under uncertain conditions plastic moment by direct method. The stochastic models are normal or lognormal distribution. New formulations derived to compute lower bound and upper loads dual algorithm is established calculate load factors simultaneously chosen structural reliability level. An example examined illustrate shows robust results analysis.

10.48084/etasr.9577 article EN Engineering Technology & Applied Science Research 2025-04-03

Background: Numerous single- and double-row repair techniques with simple modified stitches have been described for subscapularis tendon tears. Purpose/Hypothesis: This study aimed to uniformly evaluate the influence of 4 different on biomechanical performance fixation full-thickness It was hypothesized that (1) 2 single-row would require more cycles result in 3- 5-mm gap formation a higher load failure after cyclic loading than technique (2) also significantly compared technique. Study...

10.1177/23259671241302069 article EN cc-by-nc-nd Orthopaedic Journal of Sports Medicine 2025-04-01

Background/Aims: Common systems for the quantification of cellular contraction rely on animal-based models, complex experimental setups or indirect approaches. The herein presented CellDrum technology testing mechanical tension monolayers and thin tissue constructs has potential to scale-up towards medium-throughput analyses. Using hiPS-Cardiac Myocytes (hiPS-CMs) it represents a new perspective drug brings us closer personalized medication. Methods: In present study, self-beating hiPS-CMs...

10.1159/000443124 article EN cc-by-nc-nd Cellular Physiology and Biochemistry 2016-01-01

After menopause, decreased levels of estrogen and progesterone remodel the collagen soft tissues thereby reducing their stiffness. Stress urinary incontinence is associated with involuntary urine leakage due to pathological movement pelvic organs resulting from lax suspension system, fasciae, ligaments. This study compares changes in orientation position female weakened ligaments, combined laxity. A mixture theory weighted by respective volume fraction elastin-collagen fibre compound (5%),...

10.1155/2018/9518076 article EN cc-by Computational and Mathematical Methods in Medicine 2018-01-01

10.1016/s0029-5493(00)00415-5 article EN Nuclear Engineering and Design 2001-06-01

To elaborate the impact of new haemostatic agents we developed an instrument for pressure-controlled induction blunt liver injuries in a porcine animal model.A dilutional coagulopathy 80% blood volume was induced 9 anaesthetized pigs. Animals were randomly assigned to be injured with force 112 Newton (N) (n = 1), 224 +/- 19 N 4) or 355 35 4). The injury measured by loss, survival time and coagulation parameters. Liver histology obtained evaluate degree injury.The profound haemodilution...

10.1159/000265053 article EN European Surgical Research 2009-12-09

Summary Dental trauma is a common complication of tracheal intubation. As existing evidence insufficient to validly assess the impact different laryngoscopy techniques on incidence dental trauma, force exerted onto structures during intubation was investigated. An manikin equipped with hidden sensors in all maxillary incisors. measured while 104 anaesthetists performed series intubations using direct Macintosh blade, and videolaryngoscopy C‐ MAC ® , or hyperangulated GlideScope KingVision...

10.1111/anae.14815 article EN cc-by-nc-nd Anaesthesia 2019-08-25

10.1023/a:1008321026063 article EN Journal of Global Optimization 2000-01-01

Abstract The paper describes the application of primal‐dual theory limit and shakedown analysis in safety assessment design pressure components according to new European approach by analysis. Two methods, static kinematic one, their combination, method, are discussed. A numerical example is presented show robustness method compared with two other methods recently used projects on design. Copyright © 2006 John Wiley & Sons, Ltd.

10.1002/cnm.891 article EN Communications in Numerical Methods in Engineering 2006-08-14

10.1016/j.ijpvp.2004.07.022 article EN International Journal of Pressure Vessels and Piping 2004-09-21

Surgical reconstruction of the interosseous membrane may restore longitudinal forearm stability in Essex-Lopresti lesions. This study aimed to compare intact with a single-bundle and double-bundle central band using digital image correlation three-dimensional camera system. Single cyclic axial loading eight fresh-frozen specimens was carried out state, after creation an lesion, TightRope® (Arthrex GmbH, Munich, Germany) construct. Instability significantly increased lesion. The similar both...

10.1177/1753193416665943 article EN Journal of Hand Surgery (European Volume) 2016-08-29
Coming Soon ...