J. A. Adams

ORCID: 0009-0002-2340-6014
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • High-Voltage Power Transmission Systems
  • Groundwater flow and contamination studies
  • Smart Grid and Power Systems
  • HVDC Systems and Fault Protection
  • Welding Techniques and Residual Stresses
  • Advanced Welding Techniques Analysis
  • Structural Integrity and Reliability Analysis
  • Grouting, Rheology, and Soil Mechanics
  • Innovative Microfluidic and Catalytic Techniques Innovation
  • Enhanced Oil Recovery Techniques
  • Power System Optimization and Stability
  • Power System Reliability and Maintenance
  • Heavy Metal Exposure and Toxicity
  • CO2 Sequestration and Geologic Interactions
  • Satellite Communication Systems
  • Material Properties and Failure Mechanisms
  • Intermetallics and Advanced Alloy Properties

Amgen (United States)
2021

University of Illinois Chicago
1998

Ralph M. Parsons Foundation
1960

More than 9 GW of wind capacity has been connected to the Electric Reliability Council Texas (ERCOT) grid. In order accommodate installation future generation, Competitive Renewable Energy Zone (CREZ) transmission expansion project planned. The CREZ includes over two thousand miles new 345kV lines and is expected be completed by 2014. Planning studies have conducted ensure that generation can reliably delivered ERCOT grid through facilities. Voltage oscillations temporary overvoltage were...

10.1109/pesgm.2012.6344713 article EN 2012-07-01

THE existence of transient recovery-voltage phenomena in connection with the interruption short circuits by circuit breakers has been recognized for a number years, and from time to measurements calculations have made on actual field circuits.2,5 However, while these more or less isolated scattered instances provided some valuable information, they not afforded comprehensive picture transient-recovery voltage conditions existing field.

10.1109/t-aiee.1942.5058586 article EN Transactions of the American Institute of Electrical Engineers 1942-09-01

WHILE there have been a number of papers on recovery voltage and its effect the operation circuit-interrupting devices, although transient characteristic are assuming more important place in design application circuit breakers with growth increasing capacity power systems, has not available to average power-company engineer convenient method for determining this characteristic. The present paper offers such also tabulates capacitance data elements.

10.1109/t-aiee.1942.5058441 article EN Transactions of the American Institute of Electrical Engineers 1942-11-01

10.1023/a:1008884213834 article EN Geotechnical and Geological Engineering 1998-01-01

Challenges for data storage during drug development have become increasingly complex as the pharmaceutical industry expands in an environment that requires on-demand availability of and resources users across globe. While efficiency relative low cost cloud services attractive, hesitancy toward use has decreased there been a significant shift real-world implementation. Within GxP laboratories, considerations include integrity security, well access control usage around In this review,...

10.4155/bio-2021-0137 article EN Bioanalysis 2021-09-01

For Eddystone Station there is a separate auxiliary power system for each main unit to supply the with essential auxiliaries and station common plant equipment, services, starting requirements. Each of these systems radial 4-kv ties between only emergency supply. Reliability has been built into by maintaining simplicity design, omission complicated automatic throwover schemes, use modern equipment adequate capacity.

10.1109/aieepas.1958.4500150 article EN Transactions of the American Institute of Electrical Engineers Part III Power Apparatus and Systems 1958-04-01

The growing complexity of data-handling systems and the need for less complicated smaller decommutation devices led to development PAM/PDM station shown in Fig. 1. capability this is 100 channels and, system shown, utilized panel space 26 1/4 inches.

10.1109/iret-set.1960.5008705 article EN IRE Transactions on Space Electronics and Telemetry 1960-01-01

TPS 631: Metals and health 1, Johan Friso Foyer, Floor August 27, 2019, 3:00 PM - 4:30 Background: Lead is a toxic metal known to affect cognitive development in children even at low exposure levels. We examined the relationship between remediation activities, soil concentrations children's blood lead levels among living near smelter that operated from 1871-1997 Omaha, Nebraska. Methods: assembled cohort of with measurements surveillance program linked them U.S. Environmental Protection...

10.1097/01.ee9.0000611128.70569.fa article EN cc-by-nc-nd Environmental Epidemiology 2019-10-01
Coming Soon ...