Xianxian Jiang

ORCID: 0000-0001-8119-0149
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Radiation Dose and Imaging
  • Medical Imaging Techniques and Applications
  • Hepatocellular Carcinoma Treatment and Prognosis
  • MRI in cancer diagnosis
  • AI in cancer detection
  • Liver Disease Diagnosis and Treatment
  • Advanced X-ray and CT Imaging
  • Spectroscopy Techniques in Biomedical and Chemical Research
  • Vascular Procedures and Complications
  • Neurological Disease Mechanisms and Treatments
  • Lymphoma Diagnosis and Treatment
  • Thyroid Cancer Diagnosis and Treatment
  • Photonic and Optical Devices
  • Gallbladder and Bile Duct Disorders
  • Microwave Engineering and Waveguides
  • Ultrasound and Hyperthermia Applications
  • Advanced Radiotherapy Techniques
  • Medical Research and Treatments
  • Cardiac pacing and defibrillation studies
  • Cardiac Arrhythmias and Treatments
  • Cardiac Imaging and Diagnostics
  • Cardiac, Anesthesia and Surgical Outcomes
  • Organ Transplantation Techniques and Outcomes
  • Cholangiocarcinoma and Gallbladder Cancer Studies
  • Pediatric Hepatobiliary Diseases and Treatments

Anhui Provincial Hospital
2022-2024

University of Science and Technology of China
2022-2024

Bengbu Medical College
2024

Australian Research Council
2021

The University of Queensland
2021

Philips (Netherlands)
2012-2014

Catharina Ziekenhuis
2013

Radboud University Nijmegen
2013

Duke Medical Center
2012

Abstract Operator radiation and the protection efficacy of a ceiling-suspended lead screen were assessed during coronary angiography (CA) in catheterization laboratory. An anthropomorphic phantom was placed under X-ray beam to simulate patient attenuation eight CA projections. Using real-time dosimeters, dose rates measured on models mimicking primary operator (PO) an assistant. Subsequently, three commonly used positions compare efficacy. The exposure PO 2.3 227.9 (mean: 67.2 ± 49.0)...

10.1038/srep42077 article EN cc-by Scientific Reports 2017-02-07

Evaluation of Patient Effective Dose Neurovascular Imaging Protocols for C-Arm Cone-Beam CTChu Wang1,2, Giao Nguyen2, Greta Toncheva2,3, Xianxian Jiang4, Andrew Ferrell3, Tony Smith3 and Terry Yoshizumi2,3,5Audio Available | Share

10.2214/ajr.13.11001 article EN American Journal of Roentgenology 2014-04-23

Annual T1 stage papillary thyroid carcinoma (PTC) incidence rates continue to rise, yet the optimal treatment for this cancer type remains controversial. Central lymph node metastasis (CLNM) is a critical determinant in context of decision-making. While several prior studies have evaluated patients with clinica l T1a(cT1a) PTC, there been fewer analyses clinical T1b(cT1b) disease date. The present study was thus formulated explore predictors CLNM cT1a and cT1b PTC.A retrospective analysis...

10.3389/fendo.2022.880911 article EN cc-by Frontiers in Endocrinology 2022-06-03

Short-term outcomes of radiofrequency ablation for hepatocellular carcinoma using cone-beam computed tomography planning and image guidance

10.12998/wjcc.v9.i7.1580 article EN World Journal of Clinical Cases 2021-02-27

To assess patient radiation during catheter ablation procedures and operator differences. From 84 patients (51 males, age 63 ± 10 years) undergoing complex by three experienced operators we collected: body mass index (BMI), procedure type time, fluoroscopy dose area product (DAP), air kerma X-ray system setting (cine, collimation angiographic imaging angle). A new factor, DAP-fluoroscopy time ratio, was introduced to compare The results show the average 179 (± 57) minutes (min), 31 21) min,...

10.15420/aer.2013.2.2.141 article EN cc-by-nc Arrhythmia & Electrophysiology Review 2013-01-01

With the rapid development of large-scale integrated photonics, optical phased array (OPA) is an effective way to realize highly integrated, stable and low-cost beam control system. Achieving a large field view (FOV) in longitudinal direction without increasing fabrication cost system complexity still significant challenge OPA antennas. Here, high sensitivity scanning range antenna based on subwavelength structure proposed enhance free-space radiating efficiency by using ridge-waveguide...

10.48550/arxiv.2403.10026 preprint EN arXiv (Cornell University) 2024-03-15

Abstract Objective. Automated detection and segmentation of breast masses in ultrasound images are critical for cancer diagnosis, but remain challenging due to limited image quality complex tissues. This study aims develop a deep learning-based method that enables accurate mass images. Approach. A novel convolutional neural network-based framework combines the You Only Look Once (YOLO) v5 network Global-Local (GOLO) strategy was developed. First, YOLOv5 applied locate regions interest...

10.1088/1361-6560/ad61b6 article EN Physics in Medicine and Biology 2024-07-26

Objective: This study aims to optimize the downgrading of BI-RADS class 4a nodules by combining various sectional elastography techniques with age Materials and Methods: We performed conventional ultrasonography, strain (SE), shear wave (SWE) on patients. Quantitative parameters recorded included age, cross-sectional longitudinal area ratios (C-EI/B, L-EI/B), rate (C-SR, L-SR), overall average elastic modulus values (C-Emean1, L-Emean1), five-point (C-Emean2, L-Emean2), maximum (C-Emax,...

10.2174/0115734056307595240911075111 article EN cc-by Current Medical Imaging Formerly Current Medical Imaging Reviews 2024-10-02

Suboptimal stent-graft placement at the lower anastomosis during transjugular intrahepatic portosystemic shunt (TIPS) may result in early stenosis and occlusion owing to incomplete covering of parenchymal tract by covered part stent-graft.To determine optimal portal venous projection view for TIPS potential influence vein anatomy.On 76 cirrhotic patients (48 men 28 women) selected TIPS, rotational, three-dimensional (3D), catheter-directed angiography was performed. The 3D portograms were...

10.1258/ar.2012.120403 article EN Acta Radiologica 2012-09-01

The validity of effective dose (ED) in medical applications, which mostly involving partial-organ irradiation, has long been argued. We now propose a new algorithm evaluation for radiation exposure. will include Relative Volume Factors, or RVFs, to account the relative irradiated volume partially-irradiated organs, such as skin and bone marrow.To validate proposed algorithm, three ED methods were applied five neuro-imaging protocols C-arm cone-beam CT: 1) MOSFET-anthropomorphic- phantom...

10.1118/1.4734721 article EN Medical Physics 2012-06-01
Coming Soon ...