- Aortic aneurysm repair treatments
- Aortic Disease and Treatment Approaches
- Cardiac Valve Diseases and Treatments
- Vascular Procedures and Complications
- Cardiac, Anesthesia and Surgical Outcomes
- Cardiac and Coronary Surgery Techniques
- Infective Endocarditis Diagnosis and Management
- Abdominal vascular conditions and treatments
- Infectious Aortic and Vascular Conditions
- Peripheral Artery Disease Management
- Cardiac Structural Anomalies and Repair
- Renal and Vascular Pathologies
- Vascular Anomalies and Treatments
- Venous Thromboembolism Diagnosis and Management
- Trauma Management and Diagnosis
- Mechanical Circulatory Support Devices
- Pleural and Pulmonary Diseases
- Tracheal and airway disorders
- Lymphatic Disorders and Treatments
- Gastrointestinal disorders and treatments
- Cardiac pacing and defibrillation studies
- Vascular Malformations and Hemangiomas
- Coronary Interventions and Diagnostics
- Coronary Artery Anomalies
- Cerebrovascular and Carotid Artery Diseases
Campbell Clinic
2020-2024
University of Tennessee Health Science Center
2012-2023
Alder Hey Children's NHS Foundation Trust
2023
Baptist Memorial Hospital
1981-2021
Saint Luke's Hospital
2020
Memphis Health Center
2017
University of Tennessee at Knoxville
1985-1989
Dartmouth–Hitchcock Medical Center
1988
Washington University in St. Louis
1986
University of Oxford
1984
A 42-year-old man had extensive occlusive disease of the coronary artery and angina pectoris. An autogenous saphenous vein bypass from ascending aorta to anterior descending was performed on Nov 23, 1964. The patient suffered an asymptomatic myocardial infarction during operation but made uncomplicated recovery. Seven years after operation, graft functions with normal left ventricular hemodynamics, while process has produced obstruction main almost complete occlusion right artery. To our...
BackgroundThe TRANSFORM (Multicenter Experience With Rapid Deployment Edwards INTUITY Valve System for Aortic Replacement) trial (NCT01700439) evaluated the performance of rapid deployment aortic valve replacement (RDAVR) system in patients with severe stenosis.MethodsTRANSFORM was a prospective, nonrandomized, multicenter (n = 29), single-arm trial. is comprised cloth-covered balloon-expandable frame attached to Carpentier-Edwards PERIMOUNT Magna Ease valve. Primary and effectiveness...
DeBakey, Michael E. M.D.; Crawford, STANLEY Garrett, H. Edward Beall, Arthur C. Jr. Howell, J. F. M.D. Author Information
DE BAKEY, MICHAEL E. M.D.; GARRETT, H. EDWARD HOWELL, JIMMY F. MORRIS, GEORGE C. Jr. M.D. Author Information
DE BAKEY, MICHAEL E. M.D.; Crawford, Stanley Garrett, H. Edward COOLEY, DENTON A. MORRIS, GEORGE C. JR. ABBOTT, JACK P. M.D. Author Information
Objective: Patients with elevated CHA 2 DS -VASc scores are at high risk for atrial fibrillation (AF) and thromboembolic events (TE) after cardiac surgery. Left appendage exclusion (LAAE) is a permanent, continuous approach to stroke prevention in AF, overcoming limitations of oral anticoagulation (OAC). We report ATLAS trial results focused on LAAE technical success perioperative safety TE rates without surgery patients who developed postoperative AF (POAF). Methods: (NCT02701062) was...
ObjectiveEndovascular repair of abdominal aortic aneurysm (AAA) remains a challenging clinical scenario when there is short or nonexistent segment healthy infrarenal aorta. This study sought to determine the safety and effectiveness endosuture (ESAR) using Endurant II/IIs endograft (Medtronic Vascular, Santa Rosa, Calif) in conjunction with Heli-FX EndoAnchors Vascular) treatment short-neck AAA.MethodsIn this subgroup analysis, 70 patients were identified from Aneurysm Treatment Using...