Koichi Mori

ORCID: 0000-0002-4460-9905
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Advanced X-ray Imaging Techniques
  • Osteoarthritis Treatment and Mechanisms
  • Total Knee Arthroplasty Outcomes
  • Lower Extremity Biomechanics and Pathologies
  • Liver Disease and Transplantation
  • Advanced X-ray and CT Imaging
  • X-ray Spectroscopy and Fluorescence Analysis
  • Gastric Cancer Management and Outcomes
  • Colorectal Cancer Surgical Treatments
  • Nuclear Physics and Applications
  • Medical Imaging Techniques and Applications
  • Laser-Plasma Interactions and Diagnostics
  • Orthopaedic implants and arthroplasty
  • Gastrointestinal disorders and treatments
  • Radiomics and Machine Learning in Medical Imaging
  • Peripheral Artery Disease Management
  • Organ Transplantation Techniques and Outcomes
  • Vascular Malformations Diagnosis and Treatment
  • Vascular anomalies and interventions
  • Breast Lesions and Carcinomas
  • Pericarditis and Cardiac Tamponade
  • Spinal Cord Injury Research
  • Thermal Regulation in Medicine
  • Advanced MRI Techniques and Applications
  • Cerebral Venous Sinus Thrombosis

Ibaraki Prefectural University of Health Sciences
2008-2023

Fujisawa City Hospital
2022-2023

Nagoya Medical Center
2021

National Hospital Organization
2021

Tsuchiura Kyodo General Hospital
2003-2020

Japanese Red Cross Nagoya Daiichi Hospital
2012-2017

AO Foundation
2007

Kyoto University
2007

National Rehabilitation Center
2001

Tottori University
1998-2001

Laser-Compton scattering (LCS) x-ray sources have recently attracted much attention for their potential use at local medical facilities because they can produce ultrashort pulsed, high-brilliance, and quasimonochromatic hard x rays with a small source size. The feasibility of in-line phase-contrast imaging “thick” biological specimens rat lumbar vertebrae using the developed compact LCS-X in AIST was investigated promotion clinical imaging. In higher-quality images, anatomical details...

10.1063/1.2903148 article EN Applied Physics Letters 2008-03-31

10.1016/j.nima.2010.04.001 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2010-04-10

PURPOSE: To classify the veins of Retzius demonstrated at computed tomography (CT) during arterial portography (CTAP) on basis anatomic location and to evaluate relationship between frequency CT visualization associated disease. MATERIALS AND METHODS: The authors reviewed axial CTAP scans from 130 patients. Patients were classified into one two groups: patients with liver cirrhosis (group 1 [n = 81]) without 2 49]). RESULTS: pathways as follows: (a) ileocolic vein drained inferior vena cava...

10.1148/radiology.209.3.9844676 article EN Radiology 1998-12-01

We report an X-ray optical system `Owl', capable of dark-field imaging. It comprises a Bragg case asymmetric monochromator and monolithic optics housing collimator C analyzer A that can select only the refracted light by 4,4,0 diffraction crystals 1.08 mm thickness. The angular width is 0.3 µrad at energy 35 keV. has been proven one obtain image corresponding to forward beam as well bright-field or vice versa depending on specified thickness analyzer. Images due refraction contrast in...

10.1143/jjap.41.4742 article EN Japanese Journal of Applied Physics 2002-07-15

Two patients with glossopharyngeal neuralgia associated cardiac syncope were treated temporary pacemakers for and then microvascular decompression. The offending arteries the posterior inferior cerebellar artery in one patient anterior other. attached to nerve vagal at root entry zones. After surgery, free from did not occur after extracted. Implantation of a pacemaker perioperative period ensures safe

10.1080/02688690701627138 article EN British Journal of Neurosurgery 2007-01-01

Patients with knee osteoarthritis can significantly affect the function of joint in terms range and mobility have a stereotypical pattern stiffness during gait, caused by an increased resistance muscles soft tissues stance phase movement. Smoothness movement, such as walking running, is assumed to be attained adulthood; however, disruptions gait due injury or performance enhancement alter smoothness this often quantified "jerk". A higher jerk value linked decrease smoothness. However few...

10.1016/j.asmart.2018.08.002 article EN cc-by-nc-nd Asia-Pacific Journal of Sports Medicine Arthroscopy Rehabilitation and Technology 2018-09-04

Abstract Regorafenib is an oral multikinase inhibitor affecting angiogenesis, oncogenesis, metastasis, and tumor immunity. As a systemic treatment, it has been shown to provide survival benefits in hepatocellular carcinoma (HCC) patients progressing on sorafenib treatment. We report herein case of HCC with hepatic vein thrombosis protruding into the inferior vena cava (IVC-HVTT) which was successfully treated by surgery following second-line chemotherapy regorafenib. A 79-year-old man...

10.1007/s12328-019-01077-4 article EN cc-by Clinical Journal of Gastroenterology 2020-01-22

Background and objectives: There are no reports on articular stress distribution during walking based any computed tomography (CT)-finite element model (CT-FEM). This study aimed to develop a calculation of the load response (LR) phase, most burdensome phase knee, using finite method quantitative CT images. Materials Methods: The right knee 43-year-old man who had history osteoarthritis or surgeries was examined. An image obtained extension position converted flexion angle in LR phase. bone...

10.3390/medicina56020056 article EN cc-by Medicina 2020-01-29

Abstract Aim Obstructive colon cancer is locally advanced with poor prognosis. However, the effect of neoadjuvant chemotherapy (NAC) on obstructive remains unclear. Therefore, this study aimed to investigate safety and efficacy NAC in patients cancer. Methods From January 2012 December 2017, we collected patient data for clinical stage II/III at seven Yokohama Clinical Oncology Group (YCOG) institutions. The long‐term outcomes non‐NAC groups were analyzed retrospectively after adjusting...

10.1002/ags3.12736 article EN cc-by Annals of Gastroenterological Surgery 2023-08-31

Transhepatic Portosystemic ShuntsCT Appearance and Anatomic CorrelationKenji Ibukuro1, Toshitaka Tsukiyama, Koichi Mori Yoshihiro InoueAudio Available | Share

10.2214/ajr.175.1.1750153 article EN American Journal of Roentgenology 2000-07-01

This study aimed to evaluate the mechanism of progression involved in knee osteoarthritis (OA). We used computed tomography-based finite element method (CT-FEM) quantitative X-ray CT imaging calculate and create a model load response phase, wherein greatest burden is placed on joint while walking. Weight gain was simulated by asking male individual with normal gait carry sandbags both shoulders. developed CT-FEM that incorporated walking characteristics individuals. Upon simulating changes...

10.3390/jfmk8010015 article EN cc-by Journal of Functional Morphology and Kinesiology 2023-01-27

Topographic Anatomy of the Vertebral Venous System in Thoracic InletKenji Ibukuro1, Hozumi Fukuda, Koichi Mori and Yoshihiro InoueAudio Available | Share

10.2214/ajr.176.4.1761059 article EN American Journal of Roentgenology 2001-04-01

The ligament structures, its torn surface and articular cartilage of a sliced human joint specimen, which could not be detected by absorption contrast, were depicted clearly refraction-contrast imaging using Laue geometry analyzer crystal. image was recorded on mammography film without an intensifying screen at incident X-ray energy 15 keV. This technique will significantly improve clinical as the morphological information that are offered simultaneously.

10.1143/jjap.42.5874 article EN Japanese Journal of Applied Physics 2003-09-15

Purpose: This study aimed to investigate the effect of knee joint structural destruction on frontal plane hip and ankle kinematics kinetics during stance phase walking in patients with differing severities osteoarthritis (KOA). Methods: An early KOA group consisted eight subjects bilateral Kellgren–Lawrence (KL) scale scores 1 or 2. established comprised nine (18 knees) KL 3 4. To measure walking, data were obtained using motion analysis system force plates. From ground reaction data, gait...

10.1177/2309499019848085 article EN cc-by-nc Journal of orthopaedic surgery 2019-05-01

Background andObjectives: The purpose of this study was to compare the side-to-side differences in knee joint movement and moment for degree pain walking stance phase patients with bilateral osteoarthritis (KOA) comparable severity. We hypothesized that on side strong were lower compared weak pain. Materials Methods: included 11 diagnosed severe KOA. In all patients' left right knees, Kellgren-Lawrence radiographic scoring system grade level 4, femorotibial angle range motion equivalent....

10.3390/medicina55120756 article EN cc-by Medicina 2019-11-22

Resonant magnetic Bragg scattering (RMBS) for several reflections has been measured at the Fe K -edge in 3 O 4 . The normal and X-ray absorption near-edge structure (XANES) two types of ion site (tetrahedral octahedral) were successfully determined from analysis DAFS RMBS spectra on assumption that there was an electric dipole transition. obtained XANES octahedral is well explained as a mixture 2+ 3+ ions, characteristic feature pre-edge peak mainly contributed tetrahedral site.

10.1107/s0909049597016646 article EN Journal of Synchrotron Radiation 1998-05-01

Though the rubella vaccination programme for adolescent girls was introduced in Japan 1977, epidemics have occurred repeatedly. Also Sasebo, 1987, we experienced various complications as follows: encephalitis (five cases), meningitis (three), thrombocytopenic purpura (four), vascular hemolytic anemia (two), pneumonia (eight), protein‐losing gastroenteropathy (one), multiple organ disorder with encephalitis, purpura, myocarditis, hepatic and renal dysfunction congenital syndrome (CRS: three)....

10.1111/j.1442-200x.1990.tb00786.x article EN Pediatrics International 1990-02-01

Fossils inside rock have been clearly visualized utilizing an X-ray interferometer. Two types of clear images are obtained, one involves phase contrast in interference beams and the other involving refraction forward-diffracted beams. 2D monochromatic synchrotron radiation with a beam size 10 mm×10 mm photon energy 35 keV was used. Using stereographic pair images, locations fossils can easily be determined precision 0.5 mm. This method powerful nondestructive tool fields paleontology...

10.1143/jjap.39.l1009 article EN Japanese Journal of Applied Physics 2000-10-01
Coming Soon ...