Saradej Khuangsirikul

ORCID: 0000-0003-4256-5432
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Total Knee Arthroplasty Outcomes
  • Orthopaedic implants and arthroplasty
  • Orthopedic Infections and Treatments
  • Venous Thromboembolism Diagnosis and Management
  • Osteoarthritis Treatment and Mechanisms
  • Anesthesia and Pain Management
  • Shoulder Injury and Treatment
  • Inflammatory mediators and NSAID effects
  • Knee injuries and reconstruction techniques
  • Blood transfusion and management
  • Vascular Procedures and Complications
  • Pain Mechanisms and Treatments
  • Intramuscular injections and effects
  • Acute Myocardial Infarction Research
  • Cardiac, Anesthesia and Surgical Outcomes
  • Advancements in Transdermal Drug Delivery
  • Advanced materials and composites
  • Musculoskeletal synovial abnormalities and treatments
  • Bone health and treatments
  • Case Reports on Hematomas
  • Exercise and Physiological Responses
  • Bone and Joint Diseases
  • Healthcare and Venom Research
  • Rheumatoid Arthritis Research and Therapies
  • Bone health and osteoporosis research

Phramongkutklao College of Medicine
2016-2023

Phramongkutklao Hospital
2013-2023

Early diagnosis of knee osteoarthritis (OA) remains a diagnostic challenge. Urinary C-terminal cross-linked telopeptide type II collagen (urinary CTX-II) is one the potential OA biomarkers. However, conclusive evidence regarding use this biomarker as tool for early still lacking. The purposes study were to compare urinary CTX-II levels in patients with and healthy controls, evaluate correlation between levels, radiographic severity OA, patient-reported outcomes effect age gender on Asian...

10.1186/s42836-020-0024-2 article EN cc-by Arthroplasty 2020-02-10
Chavarin Amarase Aree Tanavalee Viroj Larbpaiboonpong Myung Chul Lee Ross Crawford and 89 more Masaaki Matsubara Yixin Zhou Aasis Unnanuntana Alvin Tan Anthony Pohl Apisak Angsugomutkul Apisit Patamarat Arak Limtrakul Azhar M. Merican Azlina Amir Abbas Badrul Shah Badaruddin Boonchana Pongcharoen Bui Hong Thien Khanh Li Cao Chaithavat Ngarmukos Charlee Sumettavanich Chavanont Sumanasrethakul Chee-Ken Chan Cheng‐Fong Chen Chong Bum Chang Chotetawan Tanavalee Christopher Mow Chumroonkiet Leelasestaporn Chun Hoi Yan Dang-Khoa Tran David G. Campbell David Liu Edi Mustamsir Edsel Fernandez Arandia Eun Kyoo Song G. Ruslan Nazaruddin Simanjuntak Hirotsugu Muratsu Hyonmin Choe Jamal Azmi Mohammad Jason Chi Ho Fan Ji-Hoon Bae Ji Wan Kim Jose Antonio San Juan Jose Fernando C. Syquia Jun‐Ho Kim Kang‐Il Kim Ki Ki Novito Kriskamol Sithitool Manoon Sakdinakiattikoon Mel S. Lee Mohamad Zaim Chilmi Myint Thaung Narathorn Kongsakpaisal Ngai Nung Lo Nicolaas C. Budhiparama Nikom Noree Sugano Nobuhiko Paphon Sa-ngasoongsong Pariwat Taweekitikul Peter Bernardo Piti Rattanaprichavej Piya Pinsornsak Po‐Kuei Wu Pongsak Yuktanandana Pruk Chaiyakit Rahat Jarayabhand Rami Sorial Ryuji Nagamine Saradej Khuangsirikul Saran Tantavisut Satit Thiengwittayaporn Seng Jin Yeo Siwadol Wongsak Srihatach Ngarmukos Sukit Saengnipanthkul Supparurk Suksumran Surapoj Meknavin Thakrit Chompoosang Than Win Thana Narinsorasak Thana Turajane Thanainit Chotanaphuti Thanarat Reancharoen Tokifumi Majima Ukrit Chaweewannakorn Viroj Kawinwonggowit Wanshou Guo Weerachai Kosuwon Wei Chai William J. Maloney Yee Hong Teo Yunsu Chen Yutaka Inaba Yutthana Khanasuk

10.1186/s43019-021-00101-7 article EN cc-by Knee Surgery and Related Research 2021-06-30

Abstract Ceramic‐on‐metal (CoM) hip implants were reported to experience lower wear rates in vitro as compared metal‐on‐metal (MoM) bearings, thus hinting metal‐ion release at levels vivo . In this article, we show a spectroscopic study of two short‐term retrieval cases zirconia‐toughened alumina (ZTA) femoral heads belonging CoM prostheses, which instead showed poor performances Metal contamination and abnormally high fractions tetragonal‐to‐monoclinic ( t → m ) polymorphic transformation...

10.1002/jbm.b.33689 article EN Journal of Biomedical Materials Research Part B Applied Biomaterials 2016-04-18

10.1016/j.jcot.2019.12.004 article EN Journal of Clinical Orthopaedics and Trauma 2019-12-14

Background: Both minimally invasive surgery (MIS) and computer-assisted (CAS) in total knee arthroplasty have been scientifically linked with surgical benefits. However, the long-term results of these techniques are still controversial. Most surgeons assessed outcomes regard to alignment range motion, but factors may not reflect subjective variables, namely patient satisfaction.Purpose: To compare satisfaction functional between two technical procedures MIS arthroplasty, conventional...

10.1080/24699322.2016.1249959 article EN cc-by-nc Computer Assisted Surgery 2016-01-01

Background: Indoor workers including healthcare professionals are at high risk to develop vitamin D insufficiency and deficiency, due lifestyle limited sunlight exposure. Additionally, common health problems in aging men inadequacy, hypogonadism prostate cancer.
 Objective: The study aimed determine the prevalence of testosterone specific antigen (PSA) among orthopedic surgeons with different ages regions residence.
 Methods: This cross-sectional was conducted annual meeting Royal...

10.55374/jseamed.v5i1.85 article EN cc-by-nc-nd Journal of Southeast Asian Medical Research 2021-06-22

Background: Navio Surgical System, a newer-generation robotic technology, is an image-free roboticassisted total knee arthroplasty (TKA) offering several advantages over older versions, including CT scan, the potential to dynamically assess soft tissue range of motion and ability use haptic control in bone preparation.
 Objective: The study aimed compare accuracy component alignment between robotic-assisted conventional TKA.
 Methods: Forty patients were randomly assigned two...

10.55374/jseamed.v4i1.69 article EN cc-by-nc-nd Journal of Southeast Asian Medical Research 2020-06-23

Introduction:Main population of total knee arthroplasty are elderly group which contained risks from procedure and medical condition. The amount blood loss in TKA vary different studies. Blood may cause the change hemodynamic status, risked to cardiovascular morbidity or mortality. Allogenic transfusion, associated with many immunological transfusion complications, increased cost surgery. Factors should controlled decreased complications. Objectives:Determination risk factors for is a...

10.55374/jseamed.v2i2.13 article EN cc-by-nc-nd Journal of Southeast Asian Medical Research 2018-12-26

Purpose: Primary revision total knee arthroplasty (TKA) is associated with bone loss and ligamentous insufficiency. After TKA, patients may have global instability or genu recurvatum require TKA a rotating-hinged (RHK) prosthesis. However, several studies reported variable outcomes. This study aimed to: 1) evaluate the outcomes of an RHK prosthesis; 2) compare satisfaction following TKA. Methods: The cases 18 (mean age, 71 ± 8.5 years; mean follow-up time, 24 months (range, 12–38 months) who...

10.56929/jseaortho-023-0176 article EN cc-by-nc Journal of Southeast Asian Orthopaedics 2023-04-20

10.1016/j.asmart.2017.05.019 article EN cc-by-nc-nd Asia-Pacific Journal of Sports Medicine Arthroscopy Rehabilitation and Technology 2017-07-01

Increasing numbers of hip and knee arthroplasty may associate with higher risk complications such as venous thromboembolism. Most Thai orthopedic surgeons ignore thromboprophylaxis because less symptomatic VTE in Asian population. The consensus on thromboembolism surgery consist twenty-four common questions about including their supported literatures. gold standard diagnosis is contrast venography although the duplex ultrasound has more role postoperative patients. patients undergoing seem...

10.55374/jseamed.v1i1.38 article EN cc-by-nc-nd Journal of Southeast Asian Medical Research 2017-06-27

Background: Rotational alignment of femoral and tibial prosthesis is one the important factors for outcomes total knee arthroplasty (TKA). malalignment may lead to patellar maltracking, anterior pain, femoro-tibial flexion instability premature wear polyethylene inlay. Several studies have demonstrated higher revision rates less favorable clinical results among patients with rotational malalignment. The transepicondylar axis widely accepted as best representation functional flexion-extension...

10.55374/jseamed.v1i2.25 article EN cc-by-nc-nd Journal of Southeast Asian Medical Research 2017-12-26
Coming Soon ...