Wanyu Ding

ORCID: 0009-0006-4366-7309
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Advanced Sensor Technologies Research
  • Magnetic confinement fusion research
  • High Entropy Alloys Studies
  • Calibration and Measurement Techniques
  • High-Temperature Coating Behaviors
  • Scientific Measurement and Uncertainty Evaluation
  • Geophysics and Gravity Measurements
  • Astronomical Observations and Instrumentation
  • Perovskite Materials and Applications
  • Advanced Photocatalysis Techniques
  • Superconducting Materials and Applications
  • Adsorption and biosorption for pollutant removal
  • Conducting polymers and applications
  • Electronic and Structural Properties of Oxides
  • Soil Moisture and Remote Sensing
  • Laser-Plasma Interactions and Diagnostics
  • Copper-based nanomaterials and applications
  • ZnO doping and properties
  • Advanced materials and composites
  • Magnetic Field Sensors Techniques
  • Ionosphere and magnetosphere dynamics
  • TiO2 Photocatalysis and Solar Cells
  • Adaptive optics and wavefront sensing
  • Semiconductor materials and devices
  • GNSS positioning and interference

Dalian Jiaotong University
2016-2024

Jiangxi University of Science and Technology
2024

University of California, Los Angeles
2012

Flexible pressure sensors have attracted a lot of attention in fields such as medicine and healthcare due to their ease making wearable devices. However, the development flexible is facing challenges complex manufacturing process high cost. Herein, zinc oxide (ZnO) piezoelectric film sensor with 3 × array presented through an extremely simple ultralow‐cost fabrication reported. The series again, parallel. output voltage significantly higher compared original thin‐film at same thickness. ZnO...

10.1002/adem.202201678 article EN Advanced Engineering Materials 2023-03-10

A mechanistic study was presented on the effect of SiO2/Al2O3 ratio (SAR) adsorption/desorption behaviors low-concentration volatile organic compounds (VOCs) over H-ZSM-5. In this study, n-hexane, toluene, and ethyl acetate were used as probe VOC molecules. And their adsorption isotherms different H-ZSM-5 (SARs = 25, 130, 300, 470) collected at various temperatures (30, 40, 50 °C). Results showed that high SARs conducive to adsorption, but desorption efficiency imperfect. The dependence...

10.1021/acs.iecr.2c03662 article EN Industrial & Engineering Chemistry Research 2023-03-09

Aero-engine turbine stator blades are often used in harsh environments with high temperatures and pressure prone to fatigue fractures. Real-time accurate monitoring of blade surface stress strain is critical ensure safe operation. In this study, thin-film gauges (TFSGs) that can be high-temperature above 1000 °C were designed fabricated using a PtRh6 thin film as the sensitive material. The hysteresis effect transfer upon establishing thermo-mechanical coupling finite element model...

10.3390/s22197595 article EN cc-by Sensors 2022-10-07

An accurate and continuous measurement of heat flux is needed in many long-term operation facilities order to monitor improve the life its machinery. A thin film sensor usually fabricated via sputtering, according different spatial arrangements thermocouple junctions. novel was designed, fabricated, calibrated, but connection between leads could not be fixed quickly steadily. For this purpose, paper a method seamlessly integrate has been proposed output signal. The capable simultaneously...

10.3390/coatings12111670 article EN Coatings 2022-11-03

During the titanium alloy milling process, high temperatures in tool-chip contact area will affect tool life and precision of machining. Therefore, it is essential to measure temperature continuously. In this paper, a finite element simulation model process was established using ABAQUS2020 obtain highest location when alloy. The integration wire with alumina ceramic substrate formed an integrated substrate. Furthermore, NiCr, NiSi, SiO2 films were deposited on sequentially DC pulsed...

10.3390/ma15207106 article EN Materials 2022-10-13

The chemical composition proportion of solid solution alloys in thermocouples (TCs) field is preliminarily explored by the cluster-plus-glue-atom (CPGA) model. CPGA clusters for face-centered cubic (fcc) and body-centered (bcc) structure elemental metal are established, which octahedron rhombic dodecahedron respectively. With introducing solute A element into solvent B matrix, atoms will prefer to certain sites cluster. Setting a cluster consisted as central cluster, Friedel oscillation...

10.1016/j.matdes.2022.110562 article EN cc-by-nc-nd Materials & Design 2022-03-19

Abstract Traditional thin-film thermocouples (TFTCs) have limitations in measuring real surface temperature changes aircraft because the connection between nanofilm and leads can easily fail. Despite this, how to improve this weak has rarely been addressed previous studies. In study, a lead-embedded alumina ceramic substrate is proposed durability of TFTCs. Multi-layer two-dimensional nanofilms with different electrode lengths were prepared on using DC-pulsed magnetron sputtering....

10.1088/1361-6501/acc04b article EN Measurement Science and Technology 2023-03-01

Conventional Langmuir probe techniques usually face the difficulty of being used in processing plasmas where dielectric compounds form, due to rapid failure by surface insulation. A solution problem, so-called harmonic technique, had been proposed and shown effectiveness. In this study, technique was investigated detail changing bias signal amplitudes V0, evaluated its accuracy comparing with conventional probe. It found that measured electron temperature Te increased but showing a...

10.1088/1009-0630/18/1/10 article EN Plasma Science and Technology 2016-01-01

In this paper, the temperature measuring tool based on NiCr/NiSi thin film thermocouple is developed. 6,061 aluminium alloys selected as experiment object. Based cutting area result during field test, central composite design utilised, which contains parameters of speed, feed rate and depth. Regarding each parameter, three levels are then second-order regression equation between established. The data experimental measurement corresponds well with mathematical prediction, confirms that...

10.1504/ijmr.2018.093714 article EN International Journal of Manufacturing Research 2018-01-01

Abstract In this paper, by using magnetron sputtering to prepare NiCr/NiSi thin film thermocouples, the static calibration method is used for thermocouples with rapid temperature experiments. Different curves are obtained. The Seebeck coefficient of connected wires significantly higher (41.39 μV/°C) than that (0 μV/°C). thin-film thermocouple copper wire problem K-type analyzed experimental data, which provides relevant parameter basis use thermocouple. has advantages simple equipment,...

10.1088/1742-6596/2724/1/012001 article EN Journal of Physics Conference Series 2024-03-01
Coming Soon ...