- Textile materials and evaluations
- Advanced Sensor and Energy Harvesting Materials
- Color perception and design
- Conducting polymers and applications
- 3D Shape Modeling and Analysis
- Industrial Vision Systems and Defect Detection
- Muscle activation and electromyography studies
- Thermoregulation and physiological responses
- Ergonomics and Musculoskeletal Disorders
- COVID-19 diagnosis using AI
- Additive Manufacturing and 3D Printing Technologies
- Fashion and Cultural Textiles
- Interactive and Immersive Displays
- Organic Electronics and Photovoltaics
- Cardiomyopathy and Myosin Studies
- Advanced Antenna and Metasurface Technologies
- Transition Metal Oxide Nanomaterials
- Non-Invasive Vital Sign Monitoring
- Big Data and Digital Economy
- Microwave Engineering and Waveguides
- Color Science and Applications
- Consumer Perception and Purchasing Behavior
- Infrared Thermography in Medicine
- Cardiac electrophysiology and arrhythmias
- Anomaly Detection Techniques and Applications
École Nationale Supérieure des Arts et Industries Textiles
2015-2024
Laboratoire Génie et Matériaux Textiles
2015-2024
Université de Lille
2014-2024
École Centrale de Lille
2019-2022
Qingdao University
2020
Affiliated Hospital of Qingdao University
2020
Université Lille Nord de France
2012-2018
Centre National de la Recherche Scientifique
2011
Institut d'électronique de microélectronique et de nanotechnologie
2010
A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance the skin. The main objective of this article to develop reliable washable ECG monitoring able record wirelessly send in real time a smart phone further cloud. focuses on textile electrode design production optimal...
In this paper, the washability of wearable textronic (textile-electronic) devices has been studied. Two different approaches aiming at designing, producing, and testing robust washable reliable smart textile systems are presented. The common point two is use flexible conductive PCB in order to interface miniaturized rigid (traditional) electronic threads tracks within fabric connect them antenna, electrodes, sensors, actuators, etc. first approach consists TPU films (thermoplastic...
Ventricular arrhythmia in hypertrophic cardiomyopathy (HCM) relates to adverse structural change and genetic status. Cardiovascular magnetic resonance (CMR)–guided electrocardiographic imaging (ECGI) noninvasively maps cardiac electrophysiological (EP) properties. The purpose of this study was establish whether subclinical HCM (genotype [G]+ left ventricular hypertrophy [LVH]−), ECGI detects early EP abnormality, overt HCM, the substrate status (G+/G−LVH+) phenotype. This a prospective...
Long-term monitoring of the electrical activity heart helps to detect presence potential dysfunctions, enabling diagnosis a wide range cardiac pathologies. However, standard electrodes used for electrocardiogram (ECG) acquisition are not fully integrated into garments, and generally need be with gel improve contact resistance. This article is focused on development washable screen-printed cotton, without Lycra, textile providing medical quality ECG signal long-term electrocardiography...
A development of washable PEDOT:PSS (poly(3,4-ethylenedioxythiophene) polystyrene sulfonate) polyamide textile-based electrodes is an interesting alternative to the traditional Ag/AgCl disposable electrodes, usually used in clinical practice, helping improve medical assessment and treatment before apparition or progress patients' cardiovascular symptoms. This study was conducted order determine whether physical properties had a significant impact on coated electrode's electrocardiogram (ECG)...
Reliability and washability are major hurdles facing the e-textile industry nowadays. The main fear behind product's rejection is inability to ensure its projected life span. durability of e-textiles based on an approximate lifetime both electronics textiles integrated into product. A detailed analysis wash process possibility predicting product behavior key factors for new standards implementation. This manuscript focused issues different types woven, knitted, embroidered, textile-based ECG...
Abstract This paper put forward a new interactive design approach for customized garments towards sustainable fashion using machine learning techniques, including radial basis function artificial neural network (RBF ANN), genetic algorithms (GA), probabilistic (PNN), and support vector regression (SVR). First, RBF ANNs were employed to estimate the detailed human body dimensions fulfill consumers’ ergonomics requirements. Next, GA-based models developed generate formalized solutions...
Polyelectrolytes are promising materials as gate dielectrics in organic electrochemical transistor. On the other side, fibre form transistor has become one of most interesting topics field smart textiles. The use PEDOT:PSS to realize a parallel wire textile been reported. A new geometry pattern makes easier insert into fabric making large-scale production possible. length can be up several centimeters. On/Off ratio reached 103. switch time is near 15 s. An inverter circuit and NOR-gated have...
Purpose The study in this article aims to focus on a novel design concept of virtual 3D garment which is realized with the help traditional patternmaking methodology and CAD softwares order directly conceive clothing mannequin morphotype cyberspace consideration ease allowance between body shape garment. Design/methodology/approach method acquisition human was explained at first. Then process creation model associated draping technique presented. superposition patterns from modeling used...
Abstract The miniaturized, polydimethylsiloxane (PDMS) encapsulated, reliable, and fully washable system composed of three textile stretchable electrodes connected electronic module is designed, realized, integrated to a sportswear. specifically developed made on flexible print circuit board in order facilitate its integration. software enables the recording electrocardiogram (ECG) high quality signs together with skin temperature, breathing rate, acceleration outputs that are used for an...
Large Language Models (LLMs) are prone to hallucination with non-factual or unfaithful statements, which undermines the applications in real-world scenarios. Recent researches focus on uncertainty-based detection, utilizes output probability of LLMs for uncertainty calculation and does not rely external knowledge frequent sampling from LLMs. Whereas, most approaches merely consider each independent token, while intricate semantic relations among tokens sentences well studied, limits...
Large Language Models (LLMs) are prone to hallucination with non-factual or unfaithful statements, which undermines the applications in real-world scenarios. Recent researches focus on uncertainty-based detection, utilizes output probability of LLMs for uncertainty calculation and does not rely external knowledge frequent sampling from LLMs. Whereas, most approaches merely consider each independent token, while intricate semantic relations among tokens sentences well studied, limits...
Even if smart textiles gained a certain level of maturity, they are not yet ready for the market at large scale. The main issues explaining this related to problems reliability and difficulties launder textile structures. Smart also facing launching in due lack standardizations. This paper is focused on washability standards textiles. objective co relate available mechanical tests with washing observe change their performances. First, different functions factors acting laundering machines...
Cardiovascular diseases are the leading cause of lethal issues worldwide. The most effective way to combat these is real-time monitoring electrocardiogram (ECG) that reflects electrical signals generated by heart cells. So far, ECG recorded using cutaneous conventional medical electrodes (Ag/AgCl). These not adapted for long-term use as they fully integrated into underwear and generally can provoke skin irritation, because ionic gel serves reduce impedance electrode/ interface. first part...