Research Areas
  • High-Voltage Power Transmission Systems
  • Electrical Fault Detection and Protection
  • Machine Fault Diagnosis Techniques
  • High voltage insulation and dielectric phenomena
  • Advanced Battery Technologies Research
  • Icing and De-icing Technologies
  • Industrial Technology and Control Systems
  • Power Transformer Diagnostics and Insulation
  • Corrosion Behavior and Inhibition
  • Vacuum and Plasma Arcs
  • Smart Materials for Construction
  • Lightning and Electromagnetic Phenomena
  • Smart Grid and Power Systems
  • Electric Vehicles and Infrastructure
  • Aerodynamics and Fluid Dynamics Research
  • Thermography and Photoacoustic Techniques
  • Thermal Analysis in Power Transmission
  • Advanced Decision-Making Techniques
  • Heat Transfer and Optimization
  • Structural Health Monitoring Techniques
  • Power Systems and Technologies
  • Heusler alloys: electronic and magnetic properties
  • Engineering Applied Research
  • Advanced Algorithms and Applications
  • Power System Reliability and Maintenance

Guizhou Electric Power Design and Research Institute
2024-2025

Chongqing University
2019-2024

Tongji University
2017-2023

Shanghai Pulmonary Hospital
2023

Shanghai Electric (China)
2023

Shenyang University of Technology
2021-2022

Xiangya Hospital Central South University
2014

University of California, Santa Barbara
2013

Nanchang University
2012

Electric Power Research Institute
2010-2012

Breaking short-circuit current and harmonic are two strict breaking conditions for circuit breakers. Current experimental methods difficult to test the ability of breakers under influence current, arc after high voltage components. Therefore, based on coupling simulation method magnetohydrodynamics circuits, this paper numerically models characteristics SF6circuit power frequency as well current. The opening SF6 is analyzed, conclusion drawn that may have an earlier zero crossing at higher...

10.1049/icp.2024.2285 article EN IET conference proceedings. 2025-01-01

ABSTRACT Power transformer windings are susceptible to deformation after multiple short‐circuit impulses, threatening power grid stability. Currently, there is a lack of experimental data on various characteristic parameters failures impulses. To investigate winding and its gradual deterioration, mock‐up was constructed study the cumulative effects. Short‐circuit tests were conducted under different current ratios, effect quantified based impedance axial force variations. A correlation...

10.1049/elp2.70020 article EN cc-by-nc-nd IET Electric Power Applications 2025-01-01

Mechanical defects of GAS-insulated metal-enclosed switchgear (GIS) equipment seriously threaten power grid security, but <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">on</small> -site complex operating conditions create great challenges for defect diagnosis. Therefore, this article proposes a novel diagnosis and state assessment method GIS mechanical under varying currents. First, time-frequency analysis vibration signals based on neighboring...

10.1109/tii.2023.3242805 article EN IEEE Transactions on Industrial Informatics 2023-02-06

Mechanical defect is an important reason for the failure of gas-insulated switchgear (GIS) equipment. Based on time-frequency characteristic vibration signal analysis five kinds mechanical defects, a novel intelligent algorithm model combining complementary ensemble empirical mode decomposition (CEEMD) and genetic improved kernel fuzzy mean clustering (GAKFCM) was proposed to identify type. First, platform detection system were built. Then CEEMD IMF sensitivity factors used analyse feature...

10.1049/hve2.12056 article EN cc-by-nc-nd High Voltage 2020-12-08

In order to reduce the sorting complexity of retired power batteries, life decay characteristics identification method battery module based on accelerated test is proposed in paper. Firstly, influence different parameters (environmental temperature, charge–discharge depth, rate, etc.) single analyzed according historical data batteries. The main affecting are determined. Secondly, correlation characteristic function between terminal voltage, state charge (SOC) and health (SOH) established....

10.1016/j.egyr.2022.02.120 article EN cc-by-nc-nd Energy Reports 2022-03-11

With the proposal of global energy conservation and emission reduction policies, scale grid connection Integrated Energy System (IES) is gradually increasing. How to formulate a carbon trading mechanism guide system's emissions realize operation low-carbon economy has become main problem be solved urgently. Based on this background, paper proposes multi-stakeholders management control method IES considering scheme. First, dynamic multi-energy coupling flow model electricity, heat gas in...

10.1016/j.egyr.2022.08.165 article EN cc-by-nc-nd Energy Reports 2022-08-26

In order to effectively make up for the defect of service life re-tired power battery echelon used in microgrids (MGs) and improve reliability MGs system, an energy management method based on hub electricity heat hydrogen multi-energy storage system (EHH-MESS) is proposed paper. Firstly, considering uncertain factors such as output, load fluctuation, retired defects multi flow impact, supply-demand balance model built. Secondly, taking economy supply goal, a control proposed, which considers...

10.1109/tasc.2021.3110471 article EN IEEE Transactions on Applied Superconductivity 2021-09-08

To improve the efficiency of large-scale retired power battery (RPB) sorting in echelon utilization, and a stratified method is proposed paper which takes module (BM) as object. Firstly, correlation characteristic between single BM built, main parameters affecting attenuation are defined. According to consistency static initial module, first accomplished. Secondly, characteristics function established. The output calculated by using equilibrium control method. Finally, coupling relationship...

10.1109/tasc.2021.3107803 article EN IEEE Transactions on Applied Superconductivity 2021-08-25

This paper studies the atmospheric corrosion characteristics of grid metal frame equipment in Chongqing. Through standard field test method -"exposure" method, this study carried out substation site hanging Q 235 steel power transmission and transformation engineering structural material environment, mastered data different stages. It was found that morphology, quantity products on surface varied greatly with progress corrosion. According to morphology time, combined image processing...

10.4028/www.scientific.net/kem.815.89 article EN Key engineering materials 2019-08-01

The mechanical defects of gas-insulated switchgear (GIS) equipments seriously threaten their safe and stable operation, but there are detection problems such as latency weak vibration response, especially for high-capacity GIS with large size. In this paper, a novel defect simulation method based on current excitation variable frequency is proposed to solve problem. First, 500 kV system loading capacity was designed by structural parameter adjustment, power matching harmonic suppression the...

10.1109/tim.2022.3196955 article EN IEEE Transactions on Instrumentation and Measurement 2022-01-01

Gas insulated switchgear (GIS) is widely used in power system because of its high reliability and compact structure. Mechanical defect one the main reasons for GIS equipment abnormal vibration, even insulation aging breakdown gas leakage. In order to detect identify internal mechanical fault GIS, this paper first developed a detection vibration signal based on piezoelectric acceleration sensor. After then, 110kV-3150A simulation test platform was built laboratory, two kinds defects such as...

10.1109/cmd48350.2020.9287282 article EN 2022 9th International Conference on Condition Monitoring and Diagnosis (CMD) 2020-10-25

Mechanical defects and partial discharge (PD) are two typical of GIS equipment. Both them can cause abnormal sound vibration, which may lead to misjudgment in field detection threaten the safe operation To explore difference between mechanical defect vibration PD GIS, this paper, based on actual operating test disconnector chamber, potential transformer chamber with normal status were carried out. The signals under cases normal, defects, obtained. Difference analysis from time domain,...

10.1109/catcon52335.2021.9670536 article EN 2021-12-03

10.4271/2017-01-9452 article EN SAE International Journal of Materials and Manufacturing 2017-04-11

Download This Paper Open PDF in Browser Add to My Library Share: Permalink Using these links will ensure access this page indefinitely Copy URL DOI

10.2139/ssrn.4686098 preprint EN 2024-01-01

Download This Paper Open PDF in Browser Add to My Library Share: Permalink Using these links will ensure access this page indefinitely Copy URL DOI

10.2139/ssrn.4748085 preprint EN 2024-01-01

10.1109/ceepe62022.2024.10586477 article EN 2022 5th International Conference on Energy, Electrical and Power Engineering (CEEPE) 2024-04-26

10.1109/ceepe62022.2024.10586407 article EN 2022 5th International Conference on Energy, Electrical and Power Engineering (CEEPE) 2024-04-26

10.1109/ceepe62022.2024.10586433 article EN 2022 5th International Conference on Energy, Electrical and Power Engineering (CEEPE) 2024-04-26
Coming Soon ...