Alexander Eickhoff

ORCID: 0000-0001-7767-241X
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Hip and Femur Fractures
  • Bone fractures and treatments
  • Pelvic and Acetabular Injuries
  • Esophageal and GI Pathology
  • Gastrointestinal disorders and treatments
  • Cardiac, Anesthesia and Surgical Outcomes
  • Gastric Cancer Management and Outcomes
  • Shoulder Injury and Treatment
  • Spinal Fractures and Fixation Techniques
  • Radiation Dose and Imaging
  • Shoulder and Clavicle Injuries
  • Orthopaedic implants and arthroplasty
  • Gallbladder and Bile Duct Disorders
  • Orthopedic Surgery and Rehabilitation
  • Pediatric Hepatobiliary Diseases and Treatments
  • Gastrointestinal Bleeding Diagnosis and Treatment
  • Trauma and Emergency Care Studies
  • Colorectal Cancer Treatments and Studies
  • Gastrointestinal Tumor Research and Treatment
  • Biliary and Gastrointestinal Fistulas
  • Spine and Intervertebral Disc Pathology
  • Trauma Management and Diagnosis
  • Metastasis and carcinoma case studies
  • Colorectal Cancer Screening and Detection
  • Palliative Care and End-of-Life Issues

Universität Ulm
2018-2024

University Hospital Ulm
2012-2024

Klinik und Poliklinik für Mund-, Kiefer- und Plastische Gesichtschirurgie
2023

Klinikum Hanau
2011-2013

Medical University of Vienna
2012

Johannes Gutenberg University Mainz
2011

German Cancer Society
2011

Klinik und Poliklinik für Psychosomatische Medizin und Psychotherapie
2011

Klinikum Ludwigshafen
2005-2009

Universität Hamburg
2009

Inhalt 1. Informationen zu dieser Leitlinie 462 1.1. Herausgeber 1.1.1. Federführende Fachgesellschaft 1.1.2. Kontakt 1.1.3. Verfügbare Dokumente zur 1.2. Besonderer Hinweis 1.3. Autoren 1.4. Ziele des Leitlinienprogramms Onkologie 2. Einführung 463 2.1. Geltungsbereich und Zweck 2.1.1. Zielsetzung Fragestellung 2.1.2. Adressaten 464 2.1.3. Verbreitung u. Implementierung d. Leitlinien 2.1.4. Finanzierung der Darlegung möglicher Interessenskonflikte 2.1.5. Gültigkeitsdauer...

10.1055/s-0031-1273201 article DE Zeitschrift für Gastroenterologie 2011-04-01

The prototype of the single-balloon enteroscopy system (Olympus Medical Systems Europa GmbH, Hamburg, Germany; [Fig. 1]) consists a high-resolution endoscope (XSIF-Q160Y) with working length 200 cm, and an outer diameter 9.2 mm, flexible overtube (XST-BY3A; 2]) 132 cm 13.2 mm. A latex-free balloon is only attached at tip single-use silicon overtube, inflated deflated air from pressure-controlled pump control unit MAJ-1440).

10.1055/s-2007-966616 article EN Endoscopy 2007-12-01

Hip fractures in the elderly population are common and number of patients is rising. For young geriatric with undisplaced osteosynthesis primary type treatment. The dynamic hip screw (DHS) around for many years proved its value especially displaced fractures. Since 2018 femoral neck system (FNS) available as an alternative showing promising biomechanical results. aim this study to evaluate clinical results FNS compare it DHS.Patients older than 18 Garden I-IV that were treated a level 1...

10.1007/s00402-022-04551-w article EN cc-by Archives of Orthopaedic and Trauma Surgery 2022-07-22

Abstract Introduction After surgical treatment of injuries the lower extremity, partial weight bearing is often suggested until soft tissue consolidation. It doubtful, if this recommendation can be implemented, even in case that a patient performing with physical therapist. Consequently question remains, patients are able to implement after surgery and which factors favor incompliance. Materials methods 49 patients, who underwent were equipped electronic shoe insoles on both sides. Different...

10.1007/s00402-020-03588-z article EN cc-by Archives of Orthopaedic and Trauma Surgery 2020-09-03

Abstract Introduction Osteosynthesis of femoral neck fractures (FNFs) is an important treatment option, especially for younger patients. We aimed to assess the rate early implant-related complications in FNF osteosynthesis using Femoral Neck System (FNS). Patients and methods Consecutive patients diagnosed with displaced or nondisplaced FNFs were treated FNS this prospective, observational, multicenter investigation. followed up minimally 3 months 12 if radiologic bone union no pain was not...

10.1007/s00402-022-04686-w article EN cc-by Archives of Orthopaedic and Trauma Surgery 2022-12-02

The treatment of fragility fractures the pelvis is rising challenge for orthopedic trauma surgeons. Operative should allow immediate full weight bearing and early mobilisation but also be as minimal invasive possible. Sacroiliac (SI) or transsacral transiliac screws (TSTI) alone depending on fracture in combination with an external fixator meets both these criteria.The outcome 121 operatively treated patients were evaluated this retrospective study. Depending type navigated SI screw TSTI...

10.1007/s00068-021-01780-3 article EN cc-by European Journal of Trauma and Emergency Surgery 2021-09-21

Background: Proximal femoral fractures occur with increasing incidence, especially in the elderly. Commonly used implants for surgical treatment are cephalomedullary nails. To increase stability, a perforated neck blade can be augmented cement. The study investigated whether this results relevant clinical advantage and justifies higher cost. Materials methods: This is single-center retrospective of 620 patients proximal femur treated nailing. Between January 2016 December 2020, 207 male 413...

10.3390/jcm12041661 article EN Journal of Clinical Medicine 2023-02-19

Abstract Hybrid-operating rooms (hybrid-OR) combine high-resolution 2D images and 3D-scans with the possibility of 3D-navigation allow minimal invasive pedicle screw placement even in upper thoracic spine. The disadvantage high cost increased radiation needs to be compensated accuracy safety. hybrid operating room consists a floor-based flat-panel robotic C-arm 3D-scan capability (Artis Zeego, Siemens; Germany) combined navigation (BrainLAB Curve, BrainLAB; Germany). Through minimally...

10.1007/s11701-023-01533-x article EN cc-by Journal of Robotic Surgery 2023-01-16

The invention of flat-panel detectors led to a revolution in medical imaging. major benefits this technology are higher image quality and dose reduction. Flat-panel have proved be superior standard C-arms (= C-arm with radiograph source intensifier). Cone-beam computed tomography (cone-beam CT) is 3D data set, which can acquired detector. cone-shaped beam used for generation. For cone-beam CT acquisition, the detector rotates around patient lying on operating table. Intra-operative very...

10.1302/2058-5241.3.170055 article EN cc-by-nc-nd EFORT Open Reviews 2018-05-01

Pediatric femur fractures are a major trauma in children. Different treatment algorithms have been developed but indications for surgical treatment, especially very young patients, still controversial. Literature recommends stabilization with elastic-stable intramedullary nailing (ESIN) starting at the age of 3 and non-operative younger patients. This study sought to present outcome patients than years treated ESIN fractures.Inclusion criteria were fractures. Patient demographics, fracture...

10.1007/s00068-022-01965-4 article EN cc-by European Journal of Trauma and Emergency Surgery 2022-04-08

Proximal humerus fractures are common injuries in the elderly. Locked plating showed high complication and reoperation rates at first. However, with second-generation implants augmentation, minimally invasive locked might be a viable alternative to arthroplasty or conservative treatment. A retrospective chart review was performed for all patients proximal treated between 2014 2020 plating. All over 60 years of age who underwent surgery fracture plate osteosynthesis (NCB, Philos, Philos...

10.3390/jcm11226751 article EN Journal of Clinical Medicine 2022-11-15

Proximal humerus fractures are common and often associated with osteoporosis in the elderly. Unfortunately, complication revision rate for joint-preserving surgical treatment using locking plate osteosynthesis is still high. Problems include insufficient fracture reduction implant misplacement. Using conventional intraoperative two dimensional (2D) X-ray imaging control only planes, a completely error-free assessment not possible.The feasibility of three-dimensional (3D) screw tip cement...

10.1007/s00402-023-04820-2 article EN cc-by Archives of Orthopaedic and Trauma Surgery 2023-03-06

Einleitung: Über das Gemeinsame und die Unterschiede im Verschlussprozess biliärer pankreatischer Endoprothesen ist wenig bekannt. Das Ziel der Studie war, Erkenntnisse über diese Vorgänge durch den Einsatz Rasterelektronenmikroskopie zu gewinnen. Material Methoden: Eine rasterelektronenmikroskopische Untersuchung wurde an einer konsekutiven Serie von 18 biliären 10 pankreatischen durchgeführt. Die Indikation zum Stenting bei Patienten mit (18 Männer, 5 Frauen) war eine maligne...

10.1055/s-2008-1027926 article DE Zeitschrift für Gastroenterologie 2009-04-01

Abstract Introduction Surgical treatment options for acromioclavicular joint separations are varied. Frequently, suspension devices (SD) inserted stabilization under arthroscopic view. This study investigates the feasibility and accuracy of three-dimensional (3D) digital-volume-tomography (DVT) C-arm navigated implantation with regard to general trend toward increasingly minimally invasive procedures. Materials methods The a TightRope ® suture button system via vertical drill channel through...

10.1007/s00402-023-05112-5 article EN cc-by Archives of Orthopaedic and Trauma Surgery 2023-11-08
Coming Soon ...