Raif İlktaç

ORCID: 0000-0001-8727-5143
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Analytical chemistry methods development
  • Electrochemical Analysis and Applications
  • Adsorption and biosorption for pollutant removal
  • Mass Spectrometry Techniques and Applications
  • Pharmacological Effects and Assays
  • Analytical Chemistry and Sensors
  • Pesticide Residue Analysis and Safety
  • Antibiotics Pharmacokinetics and Efficacy
  • Molecular Sensors and Ion Detection
  • Electrochemical sensors and biosensors
  • Analytical Chemistry and Chromatography
  • Metal-Organic Frameworks: Synthesis and Applications
  • Arsenic contamination and mitigation
  • Diamond and Carbon-based Materials Research
  • Radioactive element chemistry and processing
  • Clay minerals and soil interactions
  • Iron oxide chemistry and applications
  • Covalent Organic Framework Applications
  • Forensic Toxicology and Drug Analysis
  • Insect and Pesticide Research
  • Advanced Polymer Synthesis and Characterization
  • Hydrogels: synthesis, properties, applications
  • Conducting polymers and applications
  • Advanced biosensing and bioanalysis techniques
  • Analytical Methods in Pharmaceuticals

Ege University
2011-2024

Engineering Research & Analysis (United States)
2021

Abstract During the last decade, progress has been made in on‐site detection of abused drug use. Herein, we present an electrochemical biosensor for one synthetic cannabinoids (SCs), JWH‐073, using poly (methyl methacrylate) (PMMA) hyperbranched copolymer (HBC) as a base coating and antibody molecules to bind JWH‐073 surface. Modification surface is proved with various techniques such differential pulse voltammetry, cyclic impedance spectrometry. The limit linearity (in logarithmic scale)...

10.1002/celc.201800015 article EN ChemElectroChem 2018-02-21

Pesticides are harmful compounds even in trace levels for human health, so the importance of determination these is increasing day by day. Magnetite-molecularly imprinted polymer and high resolution liquid chromatography has been combined preconcentration sensitive selective pirimicarb. The developed method appeared to be rapid since total procedure detection pirimicarb can completed within one hour. magnetic reusable same used at least ten cycles Limit (LOD) was found 1.60 µg L−1 linear...

10.1080/03067319.2020.1804890 article EN International Journal of Environmental & Analytical Chemistry 2020-08-07

Biopolymers such as alginate and gelatin have attracted much attention because of their exceptional adsorption properties biocompatibility. The magnetic hydrogel beads produced used in this study had a core structure composed magnetite nanoparticles shell alginate. combination the metal-ion binding ability mechanical strength presents new approach for removal metal from water sources. were designed aluminum fully characterized using various methods, including Fourier transform infrared...

10.1021/acsomega.3c04984 article EN cc-by ACS Omega 2023-11-03

Abstract Stabilization of biomolecules on matrices is critically important. Here we constructed composite nanofibers with magnetic features by electro‐spinning nanoparticles (MNP) in an appropriate polymer matrix a collector surface for multiple uses. ‘Poly(vinylalcohol)‐polyethyleneimine/Fe 3 O 4 nanoparticles’ (PVA‐PEI/MNP) nanofiber was used the screen printed electrodes (SPE) to serve as platform glucose oxidase (GOx) biofilm model biomolecule. To show potential application this material...

10.1002/slct.201802602 article EN ChemistrySelect 2018-12-21

A sensitive and selective method based on the determination of haloperidol with usage magnetite‐molecularly imprinted polymer high‐resolution liquid chromatography has been developed. This novel is rapid as detection procedure for can be completed within a total time 1 h. The same used at least 20 times. proposed succesfully applied to synthetic urine serum samples recoveries spiked were in range 94.7–100.7%. limit quantification 2.25 7.50 μg/L, respectively. Linearity calibration graph was...

10.1002/jssc.201900158 article EN Journal of Separation Science 2019-04-13

10.1007/s00706-023-03044-9 article EN Monatshefte für Chemie - Chemical Monthly 2023-03-23

A new nickel/nickel boride-based nanosorbent which provides high sorption efficiency for tin(IV) was developed in this study. The sorbent capacity found to be 26.33 ± 2.18 mg tin(IV)/g (n = 3). Tin(IV) can determined by measuring the fluorescence signal of tin(IV)–flavonol complex. Recovery with 1 mol/L hydrochloric acid 98.70 1.29 5). limit detection and quantification method were 0.5 1.7 µg/L, respectively. calibration graph linear range 4–80 µg/L. adsorption type using isotherms....

10.1080/00387010.2016.1168453 article EN Spectroscopy Letters 2016-03-24

In this paper, magnetic-molecularly imprinted polymer was used for the preconcentration of trace levels imidacloprid in water and apple samples prior to liquid chromatography-quadrupole-time-of-flight mass spectrometric determination. The selectivity magnetic united with sensitivity high resolving power chromatographic system. developed method showed a linear range from 10.0 500.0 µg/L. quantitative recoveries were obtained 92.0%-99.0 %. relative standard deviations intra-day inter-day tests...

10.3906/kim-2101-36 article EN TURKISH JOURNAL OF CHEMISTRY 2021-05-20

Abstract A new type polymeric adsorbent, poly(allylphenol‐ co ‐hydroxyethyl methacrylate‐ ‐vinyl imidazole) (PAHV), is synthesized in this study. 2‐Hydroxyethyl methacrylate used as complementary monomers along with 1‐vinyl imidazole and allylphenol monomers. The photopolymerization method preferred a synthesis benzophenone the photoinitiator. effectiveness of PAHV against bacterial species such Escherichia coli Staphylococcus aureus investigated by Clinical Laboratory Standards Institute...

10.1002/app.55756 article EN Journal of Applied Polymer Science 2024-05-24

The adsorption behavior of aluminium ions on chamotte clay has been studied in this study. Chamotte used for the first time determination trace levels aqueous solutions. Quantitative and recovery were both rapid reached an equilibrium 30 minutes. Aluminium was detected based formation highly fluorescent Al(III)-morin complex. Two linear calibration graphs obtained range 0.5-10 µg L-1 10-100 with detection limits 0.12 1.12 L-1, respectively. characterized by scanning electron microscope...

10.18185/erzifbed.1166024 article EN Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi 2023-03-30

A molecularly imprinted polymer-based fluorimetric sensor is reported for the preconcentration and determination of 1-naphthol. Four polymers were synthesized. The polymer with highest imprinting factor was synthesized using 4-vinylpyridine as functional monomer. Ethylene glycol dimethacrylate used cross-linker 2,2″-azobis(isobutyronitrile) initiator. capacities nonimprinted 1-naphthol 44.36 ± 4.91 70.86 7.22 mg/g (n = 3), respectively. limits detection quantification 0.0012 0.0040 mg/L....

10.1080/00032719.2015.1038554 article EN Analytical Letters 2015-08-11

In the present work, reusable magnetic molecularly imprinted polymers have been used for first time as an adsorbent determination of 2-phenylphenol. Magnetic selective separation and preconcentration 2-phenylphenol native fluorescence has sensitive analyte. The developed method is rapid was completed in 40 minutes. Limit detection (LOD) found to be 1.09 µg L-1 imprinting factor 1.87. linearity calibration graph observed within range 5 - 250 L-1. Selectivity parameters showed that specific...

10.18185/erzifbed.1019227 article EN Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi 2022-03-27
Coming Soon ...