Chiwoong Choi

ORCID: 0000-0002-3904-4620
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Nuclear reactor physics and engineering
  • Nuclear Engineering Thermal-Hydraulics
  • Nuclear Materials and Properties
  • Heat Transfer and Boiling Studies
  • Innovative Microfluidic and Catalytic Techniques Innovation
  • Heat Transfer and Optimization
  • Surface Modification and Superhydrophobicity
  • Risk and Safety Analysis
  • Engineering Applied Research
  • Fluid Dynamics and Heat Transfer
  • Nuclear Physics and Applications
  • Fluid Dynamics and Thin Films
  • Plasma and Flow Control in Aerodynamics
  • Refrigeration and Air Conditioning Technologies
  • Nuclear and radioactivity studies
  • Fusion materials and technologies
  • Heat Transfer Mechanisms
  • Magnetic confinement fusion research
  • Fluid Dynamics and Mixing
  • Graphite, nuclear technology, radiation studies
  • Fault Detection and Control Systems
  • Thermodynamic and Structural Properties of Metals and Alloys
  • Combustion and Detonation Processes
  • Adhesion, Friction, and Surface Interactions
  • Nanofluid Flow and Heat Transfer

Korea Atomic Energy Research Institute
2013-2024

Gesellschaft für Anlagen und Reaktorsicherheit
2024

Sapienza University of Rome
2023

University of Wyoming
2011-2015

Pohang University of Science and Technology
1998-2012

Changwon National University
2009-2012

Wyoming Department of Education
2011-2012

University of California, Los Angeles
2010

10.1016/j.expthermflusci.2010.07.003 article EN Experimental Thermal and Fluid Science 2010-07-09

A sectoral diagnosis method for open switch faults of inverter-fed permanent magnet synchronous motor (PMSM) drives have been described. The proposed defines separate residuals each the six switches as a average difference between reference and measured pole voltage instead direct use instantaneous difference, which has varying AC quantity within one cycle rotation. How to determine plausible thresholds is described effectiveness limitation are analysed. Several sets experimental results...

10.1049/iet-epa.2011.0315 article EN IET Electric Power Applications 2012-08-23

10.1016/j.ijheatfluidflow.2011.08.002 article EN International Journal of Heat and Fluid Flow 2011-10-13

The prototype generation IV sodium-cooled fast reactor (PGSFR) has been developed by the Korea Atomic Energy Research Institute. This uses sodium as a coolant to transfer core heat energy turbine. Sodium chemical characteristics that allow it violently react with materials such water or steam. When sodium–water reaction (SWR) occurs due leakage breakage of steam generator tubes, high-pressure waves and corrosive products are produced, which threaten structural integrity components...

10.1016/j.net.2016.02.016 article EN cc-by-nc-nd Nuclear Engineering and Technology 2016-03-19

Korea imports about 97% of its energy resources due to a lack available resources. In this status, the role nuclear power in electricity generation is expected become more important future years. particular, fast reactor system one most promising types for generation, because it can utilize efficiently uranium and reduce radioactive waste. Acknowledging importance policy, long-term advanced SFR development plan was authorized by KAEC 2008 updated 2011 which will be carried out toward...

10.1155/2013/290362 article EN cc-by Science and Technology of Nuclear Installations 2013-01-01

Korea Atomic Energy Research Institute has been developing a pool-type sodium-cooled fast reactor of the Prototype Gen-IV Sodium-cooled Fast Reactor (PGSFR). To assess effectiveness inherent safety features PGSFR, system transients during design basis accidents and extended conditions are analyzed with MARS-LMR subchannel blockage events MATRA-LMR-FB. In addition, in-vessel source term is calculated based on super-safe, small, simple methodology. The results show that PGSFR meets acceptance...

10.1016/j.net.2016.08.002 article EN cc-by-nc-nd Nuclear Engineering and Technology 2016-08-26

In this study, the existing knowledge on wetting criterion, that is, intrinsic contact angle, for distinguishing between hydrophilic and hydrophobic textured surfaces is verified experimentally. A precise apparent angle measured micro-, nano-, micro-/nanotextured to quantitatively define surface-wetting conditions. particular, X-ray tomography introduced measure geometric morphologies of nano- surfaces, state clearly visualized using synchrotron imaging. By comparing previous theoretical...

10.1021/acs.langmuir.8b03407 article EN Langmuir 2019-02-18

This paper presents a numerical algorithm of the implicit coupling for multi-scale thermal hydraulic analysis developed with specific application integration component scale three-dimensional code, CUPID, and one-dimensional system SPACE. The scheme involves formulating single pressure matrix CUPID SPACE coupled domain, which is then divided into two submatrices to solve each computing domain separately. was verified using theoretical problems vertical pipes an elliptical manometer tube....

10.1016/j.anucene.2024.110382 article EN cc-by Annals of Nuclear Energy 2024-02-01

10.1007/bf03177438 article EN Journal of Mechanical Science and Technology 2007-11-01

In this Article, we describe the generation of pressure gradients on-chip for driving liquid phase separations in submicrometer deep channels. The reported pressure-generation capability was realized by applying an electrical voltage across interface two glass channel segments with different depths. A mismatch electroosmotic flow rate at junction led to pressure-driven our device, a fraction which then directed analysis carry out desired separation. Experiments showed strategy be...

10.1021/acs.analchem.5b03125 article EN Analytical Chemistry 2015-12-04

Hydrophobicity is an important parameter in a microscale two-phase thermal hydraulic system because the interfacial force has influential role this system. Previous research been limited to flow regime, with most results indicating that surface hydrophobicity parameter. However, effect on boiling not studied, especially at microscale. This due coupled difficulties of fabrication microchannel and modification its surface. study develops methods for single glass formation hydrophobic The...

10.1088/0960-1317/18/10/105016 article EN Journal of Micromechanics and Microengineering 2008-09-10
Coming Soon ...