Flavio Galliana

ORCID: 0000-0002-5188-6791
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Advanced Electrical Measurement Techniques
  • Sensor Technology and Measurement Systems
  • Scientific Measurement and Uncertainty Evaluation
  • Non-Destructive Testing Techniques
  • Advanced Sensor Technologies Research
  • Analytical Chemistry and Sensors
  • Microwave and Dielectric Measurement Techniques
  • Power Quality and Harmonics
  • Thermal Analysis in Power Transmission
  • Magnetic Properties and Applications
  • Radioactive Decay and Measurement Techniques
  • Power Transformer Diagnostics and Insulation
  • Gas Sensing Nanomaterials and Sensors
  • Electrical Contact Performance and Analysis
  • Structural Health Monitoring Techniques
  • Atomic and Subatomic Physics Research
  • Lightning and Electromagnetic Phenomena
  • Electrical and Bioimpedance Tomography
  • Power Line Communications and Noise
  • Smart Grid Energy Management
  • Advanced Battery Technologies Research
  • Electrical Fault Detection and Protection
  • High voltage insulation and dielectric phenomena
  • Electrical and Thermal Properties of Materials
  • Magnetic Field Sensors Techniques

Istituto Nazionale di Ricerca Metrologica
2016-2025

All-Russian research Institute of metrological service
2019-2023

Ferrari (Italy)
2000-2001

Istituto Nazionale di Fisica Nucleare, Galileo Galilei Institute for Theoretical Physics
2000

Abstract An automated temperature-controlled electrical DC voltage and resistance multiple reference standard (MRS) has been developed by Measurements International (MI) with the scientific support from Istituto Nazionale di Ricerca Metrologica (INRIM). The MRS includes a 10 V, 1 Ω, kΩ standards selectable via switch unit. This setup allows artifact calibration of high-end calibrators multimeters used in low-frequency measurements. two resistors are high-stability MI, while V is based on...

10.1088/1748-0221/20/02/p02002 article EN cc-by Journal of Instrumentation 2025-02-01

Metrological characterisation of static energy meters under realistic low power quality conditions is a basic requirement for proper grid control and fair billing. The paper reports about new proposed methodology, where the are tested directly recorded at installation sites. waveforms voltages currents sampled using portable instrument; they reproduced in laboratory with phantom generator, bandwidth covering up to 40th harmonic. recording site photovoltaic production facility, having nominal...

10.3390/en17061403 article EN cc-by Energies 2024-03-14

A measurement technique to calibrate current clamp meters in ac the range from 100 1500 at 50 Hz has been developed National Institute of Metrological Research (INRIM) addition primary reference systems for calibrations INRIM. This is traceable national standards dc resistance, voltage, and ratio. It based on a standard transformer (CT), 50-mΩ shunt, 61/2-digit digital voltmeter (DVM) that measures voltage shunt inserted conductor, which also meter applied, whose supplied by CT can generate...

10.1109/tim.2012.2188660 article EN IEEE Transactions on Instrumentation and Measurement 2012-04-11

Resistance standards with values in the TΩ range play an important role electrical instrumentation. The calibration of such is, thus, a service offered by many metrology institutes. techniques used to measure very high resistance differ quite substantially from applied lower ranges. For this reason, EURAMET technical committee for electricity and magnetism decided 2008 organise first time supplementary comparison at 1 100 based on well characterized travelling standards.

10.1088/0026-1394/50/1a/01008 article EN Metrologia 2013-01-01

In the framework of preparation National Institute Metrological Research (INRIM) to its participation at “Supplementary Comparison EURAMET.EM-S32 Resistance Standards 1 TΩ and 100 TΩ,” an evaluation two measurement techniques for high resistance measurements INRIM has been made. The first method, working between 10 MΩ TΩ, is based on a digital multimeter dc voltage (dcv) calibrator, second, up modified Wheatstone bridge with programmable dcv calibrators in arms electrometer as null detector....

10.1109/tim.2010.2060226 article EN IEEE Transactions on Instrumentation and Measurement 2010-08-10

The capacitance-charging method is a well-established and handy technique for the generation of dc current in 100 pA range or lower. This involves capacitance standard sampling voltmeter, highly stable devices easy to calibrate, it robust insensitive voltage burden instrument being calibrated. In this paper, we propose extender amplifier, which can be employed as plug-in component existing calibration setups, allows currents 1 nA range. has been Istituto Nazionale di Ricerca Metrologica...

10.1109/tim.2014.2298694 article EN IEEE Transactions on Instrumentation and Measurement 2014-01-31

At the National Institute of Metrological Research (INRIM) an evaluation a commercial dual source high resistance bridge has been performed.Its two main measurement modes (single measurements and multiple measurements) have investigated.The best settle time 10:1 ratio estimated to be about three times constant circuit involving resistors.This constant, in turn, depends on highest value resistor.By means mathematical estimators, suitable numbers readings detector established order minimize...

10.24425/mms.2022.142276 article EN cc-by-nc-nd Metrology and Measurement Systems 2023-11-06

At IEN, the scale of resistance in field 100 k/spl Omega/ to 1 T/spl has been revised through characterization a series new standard resistors. The preliminary study, realization and four measurement methods are also described this paper. complete description automatic method for calibration high-value resistors, particularly range 10 M/spl Omega/-1 Omega/, their at different voltage levels reported. It makes use programmable high-stability dc calibrator which supplies V/sub out/ an unknown...

10.1109/19.872914 article EN IEEE Transactions on Instrumentation and Measurement 2000-01-01

A calibration/verification testbed for electrical energy meters is under development at the Istituto Nazionale di Ricerca Metrologica, National Metrology Institute of Italy. The will be employed calibration commercial static power low conditions and simulating verification in field real operational conditions. activity collaboration with Ministry Economic Development aims to future regulatory documents metering verification.

10.1016/j.measen.2021.100188 article EN cc-by-nc-nd Measurement Sensors 2021-09-23

In the framework of revision and optimization measurement techniques for high-resistance measurements at National Institute Metrological Research (INRIM), a 100 MOmega-step Hamon-guarded network was projected built. With this transfer standard, 2sigma uncertainty maintained 1 GOmega standard INRIM is now on order 7.0 times 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-6</sup> voltage V. Details Hamon stability data in parallel...

10.1109/tim.2009.2015709 article EN IEEE Transactions on Instrumentation and Measurement 2009-07-07

Measurement comparisons or inter-laboratory (ILCs) are the main tool to establish measurements' compatibility between different laboratories measurement methods. Therefore, they a mean equivalence of national standards maintained at National Institutes (NMI), correctness traceability transfer from NMIs secondary calibration laboratories, their accreditation processes and suitability operators' competence equipment. ILCs' role is then strategic importance as lay top chain representing system...

10.1109/mim.2019.8674638 article EN IEEE Instrumentation & Measurement Magazine 2019-03-26
Coming Soon ...