Claudio Francese

ORCID: 0000-0003-1824-8111
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Advanced Electrical Measurement Techniques
  • Scientific Measurement and Uncertainty Evaluation
  • Sensor Technology and Measurement Systems
  • Advanced Sensor Technologies Research
  • Atomic and Subatomic Physics Research
  • Advanced Measurement and Metrology Techniques
  • Dielectric materials and actuators
  • Fault Detection and Control Systems
  • Power Quality and Harmonics
  • Polymer Nanocomposite Synthesis and Irradiation
  • Electrical and Thermal Properties of Materials
  • Microwave and Dielectric Measurement Techniques
  • Advanced Measurement and Detection Methods
  • Advanced Frequency and Time Standards
  • Characterization and Applications of Magnetic Nanoparticles
  • Advanced MEMS and NEMS Technologies
  • Analog and Mixed-Signal Circuit Design
  • Hemodynamic Monitoring and Therapy
  • Flow Measurement and Analysis
  • Advanced machining processes and optimization
  • Particle Accelerators and Free-Electron Lasers
  • Natural Fiber Reinforced Composites
  • Particle accelerators and beam dynamics

Istituto Nazionale di Ricerca Metrologica
2001-2024

An automated temperature-controlled electrical DC voltage and resistance multiple reference standard (MRS) has been developed by Measurements International (MI) with the scientific support from Istituto Nazionale di Ricerca Metrologica (INRIM). The MRS includes a 10 V, 1 {\Omega}, k{\Omega} standards selectable via switch unit. This setup allows artifact calibration of high-end calibrators multimeters used in low-frequency measurements. two resistors are high-stability MI, while V is based...

10.48550/arxiv.2501.10697 preprint EN arXiv (Cornell University) 2025-01-18

Abstract An automated temperature-controlled electrical DC voltage and resistance multiple reference standard (MRS) has been developed by Measurements International (MI) with the scientific support from Istituto Nazionale di Ricerca Metrologica (INRIM). The MRS includes a 10 V, 1 Ω, kΩ standards selectable via switch unit. This setup allows artifact calibration of high-end calibrators multimeters used in low-frequency measurements. two resistors are high-stability MI, while V is based on...

10.1088/1748-0221/20/02/p02002 article EN cc-by Journal of Instrumentation 2025-02-01

Starting from 2019 a new central role is played by quantum standards, owing to the redefined SI, where electrical units are directly linked fundamental constants e (elementary charge) and h (Planck constant). Thus, metrologists nowadays trying extend astonishing accuracy attainable in dc measurements ac beyond, moving toward calibrations aiming voltage generation. Programmable Josephson Voltage Standards capable of fulfilling primary metrology requirements only for stepwise-approximated...

10.1016/j.measurement.2024.114981 article EN cc-by Measurement 2024-05-28

10.1016/j.flowmeasinst.2014.05.001 article EN Flow Measurement and Instrumentation 2014-05-16

The voltage and current offsets of two typical precision operational amplifiers (OPAs) with BJT FET input, respectively, were continuously measured for years. paper presents the experiment, explains method data analysis, discusses results. long-term stability turns out to be limited mainly by random walk processes.

10.1109/19.903883 article EN IEEE Transactions on Instrumentation and Measurement 2001-01-01

This paper reports about the realization of a pioneering system for pressure measurements, currently tested up to 400 kPa, based on Rayleigh scattering and with no mechanical parts interacting gas.The preliminary results showed that device exhibits strong linear dependence between gas scattered light, order 10 -5 , paving way promising innovative realizations scattering-based measurement single simple in wide range Pa 1 MPa.

10.1016/j.measen.2021.100253 article EN cc-by-nc-nd Measurement Sensors 2021-09-22

Starting from 2019 a new central role is played by quantum standards, owing to the redefined SI [1], where electrical units are directly linked fundamental constants e (elementary charge) and h (Planck constant).Thus, metrologists nowadays trying extend astonishing accuracy attainable in dc measurements ac beyond, moving sinusoidal toward calibrations of arbitrary signals.Programmable Josephson Voltage Standards capable fulfilling primary metrology requirements only for signals up few...

10.21014/tc4-2023.15 article EN 2023-01-01

Total joint arthroplasty bearings, which are most typically implanted in the human hip and knee, composed of ultra high molecular weight polyethylene (UHMWPE). However, bioactivity mechanical performance this polymer need improvement several efforts have been made with regard, order to extend material's service life expand its biomedical applications. In study, two distinct procedures for producing UHMWPE composites varying cellulose nanocrystal loadings were used (CNCs). The microstructure,...

10.1109/memea54994.2022.9856510 article EN 2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA) 2022-06-22

At the National Institute of Metrological Research a convenient setup to verify DMMs linearity has been developed.It consists in top-class calibrated DC Voltage calibrator supplying directly under test.Some Keysight 3458A, Fluke 8508A and an 8588A are being enrolled tests.This is also compared with another Digital Analog Converter (R -2R DAC) place calibrator.The verified both when just switched on at thermal regime.The interference input stages connected parallel during measurements by...

10.21014/tc4-2022.13 article EN 2022-01-01
Coming Soon ...