O. Kadri

ORCID: 0000-0002-8328-6483
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Radiation Detection and Scintillator Technologies
  • Advanced Radiotherapy Techniques
  • Radiation Dose and Imaging
  • Advanced X-ray and CT Imaging
  • Radiation Therapy and Dosimetry
  • Medical Imaging Techniques and Applications
  • Particle Detector Development and Performance
  • Radiation Shielding Materials Analysis
  • Radiation Effects and Dosimetry
  • Particle physics theoretical and experimental studies
  • Nuclear Physics and Applications
  • Nuclear reactor physics and engineering
  • Particle Accelerators and Free-Electron Lasers
  • Digital Radiography and Breast Imaging
  • Electron and X-Ray Spectroscopy Techniques
  • Particle accelerators and beam dynamics
  • Magnetic and Electromagnetic Effects
  • Graphite, nuclear technology, radiation studies
  • Radioactivity and Radon Measurements
  • MRI in cancer diagnosis
  • Radiation Effects in Electronics
  • Plasma Diagnostics and Applications
  • Agronomic Practices and Intercropping Systems
  • Nematode management and characterization studies
  • Sesame and Sesamin Research

Centre National des Sciences et Technologies Nucléaires
2004-2024

King Saud University
2014-2022

Tunis El Manar University
2019-2021

Federal University of Agriculture
2008

National Engineering School of Tunis
2008

An overview of the electromagnetic (EM) physics Geant4 toolkit is presented.Two sets EM models are available: "Standard" initially focused on high energy (HEP) while "Low-energy" was developed for medical, space and other applications.The provide a faster computation but less accurate keV energies, more CPU time consuming.A common interface to has been allowing natural combination ultra-relativistic, relativistic low-energy same run providing both precision performance.Due this migration...

10.15669/pnst.2.898 article EN Progress in Nuclear Science and Technology 2011-10-01

Recent progress in development of single and multiple scattering models within the Geant4 toolkit is presented. Different options available to users are discussed. The comparisons with data shown. trade precision versus CPU performance discussed focus on LHC detectors simulation.

10.1088/1742-6596/219/3/032045 article EN Journal of Physics Conference Series 2010-04-01

10.1016/j.nimb.2007.02.088 article EN Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms 2007-02-26

10.1016/j.nimb.2009.09.015 article EN Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms 2009-09-18

We report on developments of the Geant4 electromagnetic physics sub-libraries release 10.4 and beyond. Modifications are introduced to models photoelectric effect, bremsstrahlung, gamma conversion, single multiple scattering. The theory-based Goudsmit-Saunderson model electron/positron scattering has been recently reviewed a new improved version, providing most accurate results for electrons positrons, was made available. updated interfaces, configurations have already integrated into LHC...

10.1051/epjconf/201921402046 article EN cc-by EPJ Web of Conferences 2019-01-01

Tissue equivalent materials (TEM) are frequently used in research as a means to determine the delivered dose patients undergoing various therapeutic procedures. They routine quality assurance and control procedures diagnostic physics. However, very few that tissue have been developed for use at low photon energies involved diagnosis radiology. The objective of this study is describe series TEMs designed radiographically imitate human energies. adipose, cortical bone, fat, lung, muscle...

10.3390/app12020798 article EN cc-by Applied Sciences 2022-01-13

In this work we report on recent improvements in the electromagnetic (EM) physics models of Geant4 and new validations EM physics. Improvements have been made photoelectric effect, Compton scattering, gamma conversion to electron muon pairs, fluctuations energy loss, multiple synchrotron radiation, high positron annihilation. The results these developments are included version 10.1 patches previous versions 9.6 10.0 that planned be used for production run-2 at LHC. validation suite has...

10.1088/1742-6596/664/7/072021 article EN Journal of Physics Conference Series 2015-12-23

Current status of the Standard electro-magnetic (EM) package Geant4 toolkit is described. We report on stability results with respect to variation production threshold and Physics List. This illustrates trade between CPU time precision simulation predictions. New comparisons experimental data are shown. The benchmark discussed.

10.1088/1742-6596/119/3/032004 article EN Journal of Physics Conference Series 2008-07-01

10.1016/j.nimb.2005.05.052 article EN Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms 2005-07-15

An overview of the electromagnetic physics (EM) models available in Geant4 toolkit is presented. Recent improvements are focused on performance detector simulation results from large MC production exercises at LHC. Significant efforts were spent for high statistics validation EM physics. The work consolidation was achieved providing common interfaces standard (HEP oriented) and low-energy (other application domains). It allows combination ultra-relativistic, relativistic any processes. With...

10.1088/1742-6596/331/3/032029 article EN Journal of Physics Conference Series 2011-12-23

We report on the recent progress within Geant4 electromagnetic physics subpackages. Several new interfaces and models recently introduced are already used in LHC applications may be useful for any type of simulation. Significant developments were carried out to improve user interface, develop single multiple scattering, validate high energy models. Part these included 10.2 release full set available version 10.3 December, 2016.

10.1088/1742-6596/898/4/042032 article EN Journal of Physics Conference Series 2017-10-01

The Geant4 electromagnetic (EM) physics sub-packages are a component of LHC experiment simulations. During long shutdown 2 for LHC, these packages under intensive development and we report progress EM in versions 10.5 10.6, which includes faster computation, more accurate models, extensions to the validation suite. New approaches developed simulate radiation damage silicon vertex detectors configuration multiple scattering per detector region. Improvements user interfaces low-energy...

10.1051/epjconf/202024502009 article EN cc-by EPJ Web of Conferences 2020-01-01

10.1007/s41365-018-0435-8 article EN Nuclear Science and Techniques 2018-06-04

The computational voxel phantom 'High-Definition Reference Korean-Man (HDRK-Man)' was implemented into the Monte Carlo transport toolkit Geant4. model, adjusted to Korean Man, is 171 cm in height and 68 kg weight composed of ∼30 million voxels whose size 1.981 × 2.0854 mm3. Geant4 code then utilised compute dose conversion coefficients (DCCs) expressed absorbed per air kerma free for >30 tissues organs, including almost all organs required new recommendation ICRP 103, due a broad parallel...

10.1093/rpd/ncv429 article EN Radiation Protection Dosimetry 2015-10-13

10.1016/j.nimb.2005.11.142 article EN Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms 2006-01-20

Pathogenicity of Meloidogyne Incognita on Sesamum Indicum and the Efficacy Yield-Based Scheme in Resistance Designation Two screenhouse experiments were conducted 2004 2005 rainy season to investigate reaction three selected indicum cultivars against population densities a root knot nematode, incognita. Seedlings S. raised pots arranged completely randomised design inoculated with 0, 5 000, 10 000 eggs M. incognita , replicated six times. Root disease was evaluated at mid-season harvest. A...

10.2478/v10045-008-0008-7 article EN cc-by-nc-nd Journal of Plant Protection Research 2008-03-01
Coming Soon ...