Jan Kaczmarczyk

ORCID: 0000-0002-8957-8487
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Building Energy and Comfort Optimization
  • Infection Control and Ventilation
  • Thermochemical Biomass Conversion Processes
  • Building energy efficiency and sustainability
  • Indoor Air Quality and Microbial Exposure
  • Coal Combustion and Slurry Processing
  • Urban Heat Island Mitigation
  • Advanced Proteomics Techniques and Applications
  • Coal and Coke Industries Research
  • Wind and Air Flow Studies
  • Conservation Techniques and Studies
  • Noise Effects and Management
  • Monoclonal and Polyclonal Antibodies Research
  • Adsorption and biosorption for pollutant removal
  • Coal Properties and Utilization
  • Carbon Dioxide Capture Technologies
  • Cancer Cells and Metastasis
  • Adsorption, diffusion, and thermodynamic properties of materials
  • Mining and Gasification Technologies
  • Engine and Fuel Emissions
  • Coal and Its By-products
  • Zeolite Catalysis and Synthesis
  • Mass Spectrometry Techniques and Applications
  • Catalytic Processes in Materials Science
  • Waste Management and Environmental Impact

Silesian University of Technology
2016-2025

Frederick National Laboratory for Cancer Research
2018-2024

Meso Scale Discovery (United States)
2024

Wrocław University of Science and Technology
2000-2022

AGH University of Krakow
2017-2022

National Cancer Institute
2018-2019

Leidos Biomedical Research Inc. (United States)
2018

Developmental Studies Center
2018

Leidos (United States)
2018

Jagiellonian University
2012

The response of 60 human subjects to a personalized ventilation system (PVS), providing control positioning the air terminal device and airflow rate, was compared with mixing (MV). Perceived quality, thermal comfort, intensity Sick Building Syndrome symptoms performance were studied during 3 h 45 min exposures. In case MV alone room temperature 23 degrees C 26 C. PVS supplied outdoor at or 20 recirculated when C, improved perceived quality decreased SBS re-circulated through PVS. percentage...

10.1111/j.1600-0668.2004.00300.x article EN Indoor Air 2004-12-01

The analyses performed in this paper reveal that a breathing thermal manikin with realistic simulation of respiration including cycle, pulmonary ventilation rate, frequency and mode, gas concentration, humidity temperature exhaled air human body shape surface is sensitive enough to perform reliable measurement characteristics as inhaled by occupants. temperature, humidity, pollution concentration the can be measured accurately without if they are at upper lip distance <0.01 m from face. Body...

10.1111/j.1600-0668.2006.00451.x article EN Indoor Air 2007-01-03

10.1016/j.buildenv.2011.06.017 article EN Building and Environment 2011-06-30

The effect of personalized ventilation (PV) on people's health, comfort, and performance in a warm humid environment (26 28°C at 70% relative humidity) was studied compared with their responses comfortable (23°C 40% humidity). Thirty subjects participated five 4-h experiments climate chamber. Under the conditions PV, were able to control rate direction supplied flow clean air. Subjective collected through questionnaires. During all exposures, occupied tasks used assess performance. Objective...

10.1111/ina.12012 article EN Indoor Air 2012-11-07

Human response to five different air terminal devices (ATDs) for a personalized ventilation system (PVS) was studied in an experimental office under well-defined conditions. A group of 30 human subjects assessed quality and rated their thermal comfort perception draft. Two temperature levels, 23°C 26°C, two background levels the office, high low, were during experiments. Under all conditions provided outdoor at 20°C. All PVSs allowed individual control airflow rate as well adjustments supply...

10.1080/10789669.2006.10391184 article EN HVAC&R Research 2006-04-01

The paper analyses multi-variant energy simulations carried out in IDA ICE 4.8 software for a newly designed single-family building within the framework of 4E Idea. This idea assumes use energy-saving, ecological, ergonomic, and economic solutions construction operation. Energy were conducted to evaluate annual energy-saving potential developed architectural house concept, which incorporates ergonomic cost-effective solutions. Analyses optimise non-renewable primary index by selecting...

10.3390/en18020449 article EN cc-by Energies 2025-01-20

The response of 24 human subjects to local convective cooling, radiant and combined cooling was studied at 28°C 50% relative humidity. devices used were (1) a tabletop fan, (2) personalized ventilation providing stream clean air, (3) panels below above the desk in front occupant, (4) same two but with small fans blowing room air toward upper panel be cooled redirected person. A reference condition without also tested. significantly (p < 0.05) improved subjects' thermal comfort compared...

10.1080/10789669.2013.842734 article EN HVAC&R Research 2013-11-17

In this study, a controller method for window opening was developed to naturally ventilate classroom with 30 occupants. The aim improve indoor environment quality and limit the probability of COVID infection risk simultaneously. study based on building performance simulation using combined EnergyPlus, CONTAM, Python programs. Seven cases automatically windows were considered. Opening parameters optimized by genetic algorithms. It shown that functions improved ventilation considerably...

10.3390/en16020592 article EN cc-by Energies 2023-01-04

Diagnostics of natural ventilation in buildings is problematic, as the airflow rate changes considerably over time. One constant average usually assumed when calculating energy demand for a building, however, such simplification could be fraught with considerable error. The paper describes comprehensive methodology diagnostics system building and its practical application. Based on situ measurements simulations two existing (dwelling house school) Poland, real values ventilating airflows...

10.3390/en12234556 article EN cc-by Energies 2019-11-29

Works of art are sensitive to environmental factors—mainly temperature and relative humidity—which, when stable, generally recommended as ideal protection conditions, but in historical museum buildings, the required conditions difficult maintain, due a lack adequate heating, ventilation air-conditioning systems. The paper presents analysis one-year measurements humidity three different museums Poland. aim research was identify risk collections, unbalanced moisture loads unstable indoor air...

10.3390/en13020344 article EN cc-by Energies 2020-01-10

A lack of analytically robust and multiplexed assays has hampered studies the large, branched phosphosignaling network responsive to DNA damage. To address this need, we developed fully characterized a 62-plex assay quantifying protein expression post-translational modification (phosphorylation ubiquitination) after induction The linear range was over 3 orders magnitude, median inter-assay variability 10% CV vast majority (∼85%) were stable extended storage. applied in proof-of-principle...

10.1667/rr14963.1 article EN Radiation Research 2018-02-23

Immunotherapies are revolutionizing cancer care, producing durable responses and potentially cures in a subset of patients. However, response rates low for most tumors, grade 3/4 toxicities not uncommon, our current understanding tumor immunobiology is incomplete. While hundreds immunomodulatory proteins the microenvironment shape anti-tumor response, few them can be reliably quantified. To address this need, we developed multiplex panel targeted proteomic assays targeting 52 peptides...

10.3389/fimmu.2021.765898 article EN cc-by Frontiers in Immunology 2021-11-11

ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTApplication of the Dubinin-Astakhov equation to evaluation benzene and cyclohexane adsorption isotherms on steam-gasified humic acid chars from brown coalTeresa Siemieniewska, Kazimierz Tomkow, Jan Kaczmarczyk, Andrzej Albiniak, Yves Grillet, Michele FrancoisCite this: Energy Fuels 1990, 4, 1, 61–70Publication Date (Print):January 1990Publication History Published online1 May 2002Published inissue 1 January...

10.1021/ef00019a011 article EN Energy & Fuels 1990-01-01
Coming Soon ...