Susumu Takemura

ORCID: 0000-0003-0574-276X
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Total Knee Arthroplasty Outcomes
  • Orthopaedic implants and arthroplasty
  • Orthopedic Infections and Treatments
  • Knee injuries and reconstruction techniques
  • Hepatitis C virus research
  • Hip and Femur Fractures
  • Renal cell carcinoma treatment
  • Bone health and treatments
  • Bone fractures and treatments
  • Cardiac, Anesthesia and Surgical Outcomes
  • Liver Disease and Transplantation
  • Organ Transplantation Techniques and Outcomes
  • Liver Disease Diagnosis and Treatment
  • Cell Adhesion Molecules Research
  • Vascular anomalies and interventions
  • Tuberculosis Research and Epidemiology
  • Hepatocellular Carcinoma Treatment and Prognosis
  • Renal and Vascular Pathologies
  • Cardiac Ischemia and Reperfusion
  • Multiple and Secondary Primary Cancers
  • Osteoarthritis Treatment and Mechanisms
  • Pelvic and Acetabular Injuries
  • Advanced Statistical Process Monitoring
  • Inflammatory mediators and NSAID effects
  • Gastrointestinal disorders and treatments

Osaka Rosai Hospital
2023-2025

Osaka City University
1999-2022

Saiseikai Nakatsu Hospital
2017

The aim of this study was to evaluate the effects using a portable, accelerometer-based surgical navigation system (KneeAlign2) in total knee arthroplasty (TKA) on alignment femoral component, and blood loss.A 241 consecutive patients with primary osteoarthritis were enrolled prospective, randomised controlled study. There 207 women 34 men. mean age 74.0 years (57 89). KneeAlign2 used for distal resection 121 (KA2 group) conventional intramedullary guide 120 (IM group).One patient (0.8%) KA2...

10.1302/0301-620x.99b8.bjj-2016-0596.r3 article EN The Bone & Joint Journal 2017-08-01

Whether postoperative posterior pelvic tilt progression is an independent risk factor for cup revision after total hip arthroplasty (THA) with a conventional polyethylene (PE) liner unclear. This long-term follow-up study assessed the association between and THA using porous-coated anatomic (PCA) system. retrospective cohort included 94 patients who underwent PCA system participated in mean of 25 years. The Japanese Orthopaedic Association (JOA) score was clinical outcome, prosthetic...

10.1177/11207000251326473 article EN Hip International 2025-03-19

Early postoperative functional recovery is important in older patients with lower-extremity fractures to prevent disuse, and periprosthetic femoral (PFFs) are no exception. This study aimed compare the early phase after revision for PFF loose stems between cemented cementless stems.

10.1016/j.artd.2024.101467 article EN cc-by Arthroplasty Today 2024-07-20

The use of vitamin E-infused highly crosslinked polyethylene (HXLPE) in total knee prostheses is controversial. In this paper we have compared the clinical and radiological results between conventional HXLPE inserts arthroplasty (TKA).The study included 200 knees (175 patients) that underwent TKA using same prostheses. all, 100 (77 had a insert (study group) (98 (control group). There were no significant differences age, sex, diagnosis, preoperative range movement (ROM), Knee Society Score...

10.1302/0301-620x.101b5.bjj-2018-1355.r1 article EN The Bone & Joint Journal 2019-04-30

Aims Vitamin E-infused highly cross-linked polyethylene (E1) has recently been introduced in total knee arthroplasty (TKA). An vitro wear simulator study showed that E1 reduced wear. However there is no published information regarding vivo Previous reports suggest newly materials which reduce do not necessarily To assist the evaluation of material before widespread use, we established an particle analysis for TKA. The aim this was to compare generation between and conventional (ArCom)...

10.1302/0301-620x.102b11.bjj-2020-0413.r1 article EN The Bone & Joint Journal 2020-11-01

We report a novel case of the simultaneous post and cone fractures polyethylene (PE) insert in mobile-bearing posterior-stabilized total knee arthroplasty. Twelve years after primary arthroplasty, 72-year-old male patient presented with recurring right instability was diagnosed wear PE based on physical radiological examinations. Revision surgery performed. The had fractured simultaneously. Moreover, femoral tibial components were direct contact each other. One year post-revision, function...

10.1016/j.artd.2024.101316 article EN cc-by-nc-nd Arthroplasty Today 2024-02-16

It remains uncertain whether an increase in the tibial slope leads to better flexion posterior-stabilized (PS) total knee prostheses.To compare intra-operative angle between standard and additional 10° posterior inserts.Between December 2014 February 2015, 22 patients (25 knees) who underwent PS mobile-bearing primary arthroplasty (TKA) were included. Flexion angles measured using either or specially-made inserts. Differences two situations analyzed determine relationship changes...

10.1186/s42836-021-00085-5 article EN cc-by Arthroplasty 2021-08-02

目前,虽然复发后的肝细胞癌行二次肝切除已经被广泛接受,但二次肝切除的适应证并不确定,作者评估了二次肝切除后的肝癌再次复发的危险因素,从而研究二次肝切除的适应证。入组对象为51例HCV相关的肝癌切除术后复发的再次行肝切除的病人。16例病人在第一次肝切除前后接受过干扰素治疗。6例病人干扰素治疗后达到长期病毒学应答标准(SVR),

10.3760/cma.j.issn.1007-8118.2009.02.031 article ZH-CN Zhonghua gan-dan waike zazhi 2009-02-28
Coming Soon ...