Eman S. Elzanfaly

ORCID: 0000-0003-0918-4662
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Analytical Methods in Pharmaceuticals
  • Analytical Chemistry and Chromatography
  • Analytical Chemistry and Sensors
  • Antibiotics Pharmacokinetics and Efficacy
  • Electrochemical sensors and biosensors
  • Pesticide Residue Analysis and Safety
  • Electrochemical Analysis and Applications
  • Spectroscopy and Chemometric Analyses
  • Analytical chemistry methods development
  • Pharmacological Effects and Assays
  • Biosensors and Analytical Detection
  • Inorganic and Organometallic Chemistry
  • Advanced Chemical Sensor Technologies
  • Chemistry and Chemical Engineering
  • Medical Imaging Techniques and Applications
  • Radiopharmaceutical Chemistry and Applications
  • Spectroscopy Techniques in Biomedical and Chemical Research
  • Drug-Induced Adverse Reactions
  • Water Quality Monitoring and Analysis
  • Protein Interaction Studies and Fluorescence Analysis
  • Phenothiazines and Benzothiazines Synthesis and Activities
  • Pancreatic function and diabetes
  • Drug Solubulity and Delivery Systems
  • Polymer Synthesis and Characterization
  • Essential Oils and Antimicrobial Activity

Cairo University
2015-2024

Egyptian Russian University
2021-2024

Abstract Butylated hydroxytoluene (BHT) and butylated hydroxyanisole (BHA) are two antioxidants that have been extensively used in many applications. Both well known for their debatable health risks due to multiple intake sources. Therefore, conservative limits set them different regulations adapted the matrices which they exist. Here we present a simple spectrofluorimetric method determination of BHT BHA based on native fluorescence synchronous scanning mode. The type solvent interval...

10.1038/s41598-024-54483-1 article EN cc-by Scientific Reports 2024-02-24

A new simple spectrophotometric method was developed for the simultaneous determination of drugs with interfering spectra in binary mixtures without previous separation. The is based on a modification ratio subtraction method. This enabled wider range application. proposed difference applied brimonidine and timolol laboratory prepared mean percentage recoveries 100.40±2.29 101.23±1.30 respectively, their pharmaceutical formulation 101.08±0.44 100.66±0.52 respectively. suggested validated...

10.1016/j.jpha.2012.04.004 article EN cc-by-nc-nd Journal of Pharmaceutical Analysis 2012-04-21

The introduction of sustainable development concepts to analytical laboratories has recently gained interest, however, most conventional high‐performance liquid chromatography methods do not consider either the effect used chemicals or amount produced waste on environment. aim this work was prove that can be replaced by greener ones with same parameters. suggested were designed so they neither use nor produce harmful and minimum in routine analysis without harming This achieved using green...

10.1002/jssc.201401151 article EN Journal of Separation Science 2014-12-26

An innovative spectrophotometric method was developed for simultaneous determination of compounds with interfering spectra in binary mixtures without previous separation, showing significant advantages over the conventional methods regarding minimal data manipulation and applicability. The proposed applied retinoic acid hydroquinone laboratory-prepared mean percentage recoveries 100.13 ± 0.31 99.99 0.04, respectively, their pharmaceutical formulation 0.86 100.07 0.58, respectively. validated...

10.1016/j.jsps.2012.03.004 article EN cc-by-nc-nd Saudi Pharmaceutical Journal 2012-03-31

Sofosbuvir is a novel direct acting antiviral agent against hepatitis C virus. In the present work, rapid, specific and reproducible isocratic reversed phase high performance liquid chromatography (RP-HPLC) method has been developed validated for determination of sofosbuvir in presence its stressed degradation products. Sobosbuvir was subjected to hydrolysis (acidic, alkaline neutral), oxidation, photolysis thermal stress, as per international conference on harmonization (ICH) conditions....

10.1093/chromsci/bmw119 article EN Journal of Chromatographic Science 2016-07-19

Abstract Gold and silver nanoparticles have witnessed increased scientific interest due to their colourful colloidal solutions exceptional applications. Comparing the localized surface plasmon resonance (LSPR) of gold is crucial for understanding optimizing optical properties. This comparison informs design highly sensitive plasmonic sensors, aids in selecting most suitable applications like surface-enhanced infrared spectroscopy (SEIRA) biomedical imaging, guides choice between based on...

10.1186/s13065-024-01157-8 article EN cc-by BMC Chemistry 2024-03-23

The present study considered the pharmacokinetic evaluation of empagliflozin after administration to Egyptian volunteers, and results were compared with other ethnic populations. FDA recognizes that standard methods defining racial subgroups are necessary compare across studies assess potential subgroup differences. design was as an open labeled, randomized, one treatment, period, single dose study. main parameters estimated Cmax, Tmax, t1/2, elimination rate constant, AUC0-t AUC0-inf....

10.1038/s41598-017-02895-7 article EN cc-by Scientific Reports 2017-05-24

Thin-layer chromatography (TLC) is an effective and simple technique for screening, evaluating, quantifying low-quality counterfeit pharmaceutical products. Smartphones have recently been used as accessible, cheap, portable detectors that can replace more complicated analytical detectors. In this work, we developed a sensitive TLC method utilizing smartphone charged-coupled device (CCD) camera not only to verify quantify some gastrointestinal tract drugs, namely, loperamide hydrochloride...

10.1021/acsomega.2c02482 article EN ACS Omega 2022-06-24

This work describes the fabrication of solid-contact potentiometric sensor to determine antiviral drug; tenofovir disoproxil fumarate. Screen-printed carbon electrodes have been selected as being a disposable substrate material. Ion sensing membrane is based on Polyvinyl chloride (PVC) polymer that was impregnated with calix [6] arene an ionophore for facilitating transferring drug interest from sample phase into through decreasing Gibbs free energy transfer. We applied graphene...

10.1016/j.ijoes.2024.100477 article EN cc-by-nc-nd International Journal of Electrochemical Science 2024-01-21

The electropolymerized molecularly imprinted polymers (MIP) have enabled the utilization of various functional monomers with superior selective recognition target analyte template. Methyldopa is an attractive synthetic dopamine analogue which has phenolic, carboxylic, and aminic groups. In this research, methyldopa was exploited to fabricate MIPs, for detection sofosbuvir (SFB), by a simple electropolymerization step onto disposable pencil graphite electrode (PGE) substrate. interaction...

10.1039/d3ra03870j article EN cc-by-nc RSC Advances 2023-01-01

Abstract Two methods were developed for separation and quantitation of amlodipine (AML) atorvastatin (ATV) in the presence their acidic degradation products. The first method was a simple isocratic RP-HPLC while second capillary electrophoresis (CE). Degradation products obtained by hydrolysis two drugs structures elucidated time IR MS spectra. did not interfere with determination either drug assays therefore stability-indicating. linearity proposed established over ranges 1-50 μg mL -1 AML...

10.1515/acph-2016-0040 article EN cc-by-nc-nd Acta Pharmaceutica 2016-10-15

Amantadine HCl (AMN) is a well-known antiviral agent. Chemically, AMN chromophore privation leads to the absence of UV-absorbance, condition that hinders direct spectrophotometric or simple chromatographic determination using common detectors without prior derivatization steps. In this work, an environmentally friendly ion selective electrode (ISE) method was developed for AMN, and measurements were carried out directly in aqueous solution sample pretreatment PVC-membranes fabricated...

10.1021/acssuschemeng.7b00421 article EN ACS Sustainable Chemistry & Engineering 2017-04-11

In pharmaceutical industry and clinical applications, finding real-time analyzers with minimal sample preparation is a good aim. The presented solid-contact sensor offers reasonable tool for selective, sensitive eco-friendly analysis.

10.1039/d0ay00882f article EN Analytical Methods 2020-01-01
Coming Soon ...