A. Petrucci

ORCID: 0000-0003-1517-4989
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Advanced Radiotherapy Techniques
  • Radiation Therapy and Dosimetry
  • Radiation Detection and Scintillator Technologies
  • Diamond and Carbon-based Materials Research
  • Radiation Effects and Dosimetry
  • Advanced X-ray and CT Imaging
  • Medical Imaging Techniques and Applications
  • Radiation Effects in Electronics
  • Ion-surface interactions and analysis
  • Molecular Communication and Nanonetworks
  • Semiconductor materials and devices
  • Radiation Dose and Imaging
  • Photocathodes and Microchannel Plates
  • Hearing, Cochlea, Tinnitus, Genetics
  • Spectroscopy and Laser Applications
  • Nuclear Physics and Applications
  • bioluminescence and chemiluminescence research

Ospedale San Filippo Neri
2005-2018

Azienda Sanitaria Locale Roma 3
2016

Azienda Ospedaliera G. Brotzu
2016

To determine the potentialities of synthetic single crystal diamond Schottky diodes for accurate dose measurements in radiation therapy small photon beams.The dosimetric properties a diamond-based detector were assessed by comparison with reference microionization chamber. The device was operated at zero bias voltage under irradiation high-energy radiotherapic beams. stability response and its rate dependence measured. Different square field sizes ranging from 1 × cm(2) to 10 used during...

10.1118/1.4729739 article EN Medical Physics 2012-07-02

The correction for charge recombination was determined different plane-parallel ionization chambers exposed to clinical electron beams with low and high dose per pulse, respectively. energy nearly the same (about 7 9 MeV) any of used. Boag's two-voltage analysis (TVA) used determine ion losses, k(s), relevant each chamber considered. presence free electrons in air cavity accounted determining k(s) by TVA. determination made on basis models proposed past years Boag, Hochhäuser Balk account...

10.1088/0031-9155/51/24/009 article EN Physics in Medicine and Biology 2006-11-27

10.1016/j.nima.2008.06.028 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2008-06-29

10.1016/j.nima.2009.07.004 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2009-07-11

A chemical vapour deposition diamond detector fabricated at Rome 'Tor Vergata' University was investigated for its applicability as transfer dosimeter in radiotherapy photon beams with small field sizes. The consists of a single crystal very sensitive volume (0.004 mm3). showed measurement repeatability 0.1% and long term reproducibility 0.4%. Monte Carlo simulations revealed response dependence on the beam energy about 2% from 60Co quality to 10 MV beam. calculated found be independent size...

10.1088/0026-1394/49/5/s207 article EN Metrologia 2012-08-10

LIAC® and NOVAC are two mobile linear accelerators dedicated to intraoperative radiation therapy (IORT), generating electron beams in the energy range of 3-12 MeV. Due high dose-per-pulse (up 70 mGy per pulse), 2003 Italian National Institute Health (ISS) stated that "for measure dose water reference conditions, ionization chambers cannot be employed no published dosimetry protocol can used". As a consequence, ferrous sulphate (or, alternatively alanine) was recommended. Based on...

10.1002/mp.12020 article EN Medical Physics 2017-01-01

ESTRO 36 _______________________________________________________________________________________________ angle, MLC position, and MU were 0.16° ± 0.01° (range, 0.12°-0.17°),0.08° 0.00° 0.0.7°-0.08°),0.08 0.02 mm 0.04-0.11mm), 0.37 0.05 0.30-0.44MU), respectively.In the delivered dose reconstruction, means SDs of difference all dose-volumetric indices 0.5% 0.8% 0.0%-4.2%)and 0.2% 0.0%-0.7%)for brain prostate tumors, respectively. ConclusionWe have established patient-specific QA procedure for...

10.1016/s0167-8140(17)30975-1 article EN cc-by-nc-nd Radiotherapy and Oncology 2017-05-01

Purpose/Objective: The aim of this study was to find out early cardiac changes from doxorubicin based chemotherapy and radiotherapy in patients with locally advanced carcinoma breast assess relation radiation dose received by heart.Materials Methods: Investigations like ECG, ECHO ERV (Equilibrium radionuclide ventriculography) were done at baseline, after chemotherapy, 6 months followup.Changes recorded different time periods during the study.Left ventricular ejection fraction (LVEF) using...

10.1016/s0167-8140(15)33364-8 article EN cc-by-nc-nd Radiotherapy and Oncology 2013-03-01
Coming Soon ...