Vikum K. Dewasurendra

ORCID: 0000-0003-3000-4195
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Mass Spectrometry Techniques and Applications
  • Analytical Chemistry and Chromatography
  • Semiconductor Quantum Structures and Devices
  • Microfluidic and Capillary Electrophoresis Applications
  • Terahertz technology and applications
  • Plant and animal studies
  • Ion-surface interactions and analysis
  • Particle Detector Development and Performance
  • Radiation Detection and Scintillator Technologies
  • Medical Imaging Techniques and Applications

West Virginia University
2019-2025

Capillary vibrating sharp-edge spray ionization (cVSSI) has been used to control the droplet charging of nebulized microdroplets and monitor effects on protein ion conformation makeup as determined by mass spectrometry (MS). Here it is observed that application voltage results in noticeable differences charge state distributions (CSDs) ubiquitin ions. The data can be described most generally three distinct regions: Under low-voltage conditions (<+200 V, LV regime), low states (2+ 4+ ions)...

10.1021/acs.jpcb.4c04842 article EN cc-by The Journal of Physical Chemistry B 2025-01-29

Optical rectification of near-infrared laser pulses generates broadband terahertz radiation in chalcopyrite crystals CdGeP2, ZnGeP2 and CdSiP2. The emission is characterized using linear-polarized excitation from 0.8 eV to 1.55 (1550 nm - 800 nm). All three are (110)-cut polished 0.5 mm, thinner than the coherence length across most photon energy range, such that they all produce a bandwidth ~2.5 THz when excited with ~100 fs pulses. It found CdGeP2 produced strongest at telecoms...

10.1364/oe.27.016958 article EN cc-by Optics Express 2019-06-03

Capillary vibrating sharp-edge spray ionization (cVSSI) has been used to study the effects of applied voltage and mass spectrometer heated inlet transfer tube temperature on DNA triplex ion production for native spectrometry (MS) samples. Overall, medium (-900 -1000 V) results in better desired ions (Tri) (i.e., those without cation adducts such as NH4 +, Na+, K+); spectral peak intensities [Tri]8-, [Tri]9-, [Tri]10- increase by ∼70, ∼260, ∼125 fold, respectively, compared higher voltages...

10.1021/acsomega.4c10615 article EN cc-by ACS Omega 2025-03-27

Field-free capillary vibrating sharp-edge spray ionization (cVSSI) is evaluated for its ability to conduct native mass spectrometry (MS) experiments. The charge state distributions nine globular proteins are compared using field-free cVSSI, field-enabled and electrospray (ESI). In general, both positive negative ion mode, the average (

10.1021/acs.jpcb.2c04960 article EN The Journal of Physical Chemistry B 2022-11-01

Optical rectification of near-infrared laser pulses generates broadband terahertz radiation in chalcopyrite crystals CdGeP2, ZnGeP2 and CdSiP2. In this work emission THz was compared with respect to excitation photon energy the pump intensity.

10.1364/fio.2019.jw4a.37 article EN Frontiers in Optics + Laser Science APS/DLS 2019-01-01
Coming Soon ...