- Radioactive contamination and transfer
- Archaeology and ancient environmental studies
- Geology and Paleoclimatology Research
- Isotope Analysis in Ecology
- Analytical chemistry methods development
- Archaeological Research and Protection
- Selenium in Biological Systems
- Mineralogy and Gemology Studies
- Ancient and Medieval Archaeology Studies
- Groundwater and Isotope Geochemistry
- Integrated Water Resources Management
- Geochemistry and Elemental Analysis
- Cultural Heritage Materials Analysis
- Radioactive element chemistry and processing
- Agriculture, Plant Science, Crop Management
- Plant Stress Responses and Tolerance
- Mercury impact and mitigation studies
- Geochemistry and Geologic Mapping
- Botany and Plant Ecology Studies
- Trace Elements in Health
- Arsenic contamination and mitigation
- Marine and environmental studies
- Geology and Environmental Impact Studies
- Botanical Studies and Applications
- Geological and Geophysical Studies Worldwide
University of Warsaw
2015-2024
Faculty (United Kingdom)
2016-2020
Pb isotope ratios in samples of diverse origin can be accurately measured without matrix separation.
The study investigated the total concentrations, toxicity, and health risks of 16 carcinogenic priority polycyclic aromatic hydrocarbons (PAHs) in street dust collected from urban areas Warsaw, Poland. Samples were analyzed across six granulometric fractions. Dust was 149 sampling points divided between Area 1 (central Warsaw districts, left bank Vistula River, dominated by traffic-related pollution) Areas 2 3 (suburban residential areas, right river).Street assessed both as a whole...
d26Mg values and 87Sr/86Sr ratios are used as tracers of calcite dolomite formation in the late Miocene Lake Bira. Mg Sr isotope were analyzed freshwaters brines that currently feed Sea Galilee (the modern remnant Bira) limestones dolostones comprising Bira Formation. waters (~0.89‰, ~0.7075) consistent with mixing mainly carbonate basaltic subsurface Ca-chloride (e.g., Tiberias Spa). The dolostone Formation range from ~ -1.0 to -3.5‰. -2.8 -1.8 ‰, respectively....
This study introduces a simplified purification method for analyzing 82Se/78Se isotope ratios in diverse natural samples using hydride generation MC-ICP-MS. Unlike the thiol resin method, which is time-consuming and sensitive to concentrations of reagents used at individual stages, our proposed alternative quicker, simpler, robust. The procedure involves coprecipitation selenium with iron hydroxide dissolution hydrochloric acid. Combining second cleanup stage achieves sufficient Se ratio...
Abstract The present study evaluated the level of heavy metal (HM) pollution in Vistula river sediments a highly urbanized Warsaw agglomeration (Poland). Magnetometry was used to assess by measuring fine fractions (0.071 mm and < 0.071 mm) collected from surface layer riverbank. magnetic methods (e.g., mass susceptibility χ , temperature-dependence susceptibility, hysteresis loop parameters) were supplemented microscopy observations chemical element analyses. results showed local impact...
In this study, we examine the possibility of detecting PTFE microparticles by ICP-qMS equipped with O 2 dynamic reaction cell (DRC) and operated in single-particle mode.
Liquid chromatography-high-resolution mass spectrometry was used for the first time to investigate impact of Se(IV) (10 mgSe L-1 as sodium selenite) on Allium cepa L. root proteome. Using MaxQuant platform, more than 600 proteins were found; 42 identified based at least 2 razor + unique peptides, score > 25, and found be differentially expressed in exposed versus control roots with t-test difference ±0.70 (p < 0.05, Perseus). caused growth inhibition decrease total RNA roots. Different...
In this work a high throughput, robust and sensitive method for the precise isotopic analysis of <sup>87</sup>Sr/<sup>86</sup>Sr by coupling Ion Chromatography (IC) Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS) is presented.
In this work, a method for the accurate and precise determination of 82Se/78Se isotope ratio in natural samples environmental biological origin, using multicollector inductively coupled plasma mass spectrometry wet mode without neither hydride generation nor separation Se, was developed. It based on optimized regression model with standard–sample bracketing (ORM–SSB) to efficiently correct instrumental isotopic fractionation/mass bias matrix effects. addition, three correction models SSB...
Relatively few studies have been focused so far on magnesium–isotope fractionation during plant growth, element uptake from soil, root-to-leaves transport and chlorophylls biosynthesis. In this work, maize garden cress were hydroponically grown in identical conditions order to examine if the carbon fixation pathway (C4, C3, respectively) might impact Mg-isotope chlorophyll-a. The pigment was purified plants extracts by preparative reversed phase chromatography, its identity confirmed...
Despite rich deposits of copper in SW Poland, their exploitation prehistory has not been confirmed, and the literature it is usually argued that raw materials processed Bronze Age were imported. This despite same area providing abundant evidence prehistoric metallurgy including casting moulds, tuyeres or crucibles. The concentration sites parts Sudety Mountains (in particular a region called Pogórze Kaczawskie) ores far from arable land may also indicate prospection activities this search...
Abstract This study identifies the lead ores used to produce artifacts by Romans between first and eighth centuries AD during construction of fort then town Novae (N. Bulgaria). For this purpose, samples were taken from pipes, joints columns pedestals, a ingot. The analyzed for isotopes results compared literature data Roman mines what is now Bulgaria, Greece, North Macedonia, Montenegro, Bosnia Herzegovina, Italy, Germany, Romania. Pb isotope indicate that earlier stages Novae's...
Abstract The Bronze and Early Iron Ages witnessed a significant increase in trade relations driven by the search for valuable metals. This paper presents new insights into use of galena from Silesia Krakow Upland region southern Poland, known as ‘Olkusz ore deposits’, within context metal ores prehistoric Europe. Eleven lead‐based ornaments Lusatian Urnfield Culture cemeteries were examined using lead isotope analysis. majority these found to be made local ore, which provides evidence early...
In this work, a method for the accurate and precise determination of Ge isotope ratio in synthetic water natural samples geological origin using multicollector inductively coupled plasma mass spectrometry (MC-ICPMS) with hydride generation was developed. The based on liquid–liquid extraction to eliminate all elements affecting germanium hydrides. standard-sample bracketing used correct instrumental bias. Registration analytical signal time-resolved mode gave way choose signals best...
The goal of this work was to assess differences in the composition red wine produced Poland, Hungary, Moldova, and Bulgaria, related their geographical origin. Inductively coupled plasma–mass spectrometry results obtained for 23 elements were submitted principal component analysis, indicating association Li, Co, Se, Cu, Sr with Moldovan products; Hungarian wines characterized by V, As, Al, Fe variables, whereas Be distinctive products. Polish grouped Cd Pb Bulgarian Tl, Ba, Rb, Mo; U Mn...
Abstract The development and validation of a reliable analytical procedure for the determination selected metals (Cd, Cr, Cu, Pb, Zn Mn) in sediments accumulated Utrata River (Poland) is described. aqua regia extraction followed by inductively coupled plasma optical emission spectrometry (ICP-OES) was used this purpose. optimized validated, adequate quality control actions were implemented order to provide data. precision under’ within-laboratory’ reproducibility conditions estimated from...
Abstract High‐precision on‐line procedure for measurement of calcium isotopic ratio by coupling ion chromatography to multicollector inductively coupled plasma mass spectrometry was developed. Calcium separation from the sample matrix achieved on an column—IonPac CS16—ID 3 mm connected with CERS 500 2 suppressor and followed determination. Dry mode used Aridus II desolvation system. To sustained samples high level total dissolved salts as well account capacity applied analytical column,...
A robust and sensitive method for the precise isotopic analysis of <sup>53</sup>Cr/<sup>50</sup>Cr during Cr(<sc>iii</sc>) oxidation by coupling ion pair reversed-phase chromatography Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS) is presented.