- Aortic aneurysm repair treatments
- Aortic Disease and Treatment Approaches
- Cardiac, Anesthesia and Surgical Outcomes
- Infectious Aortic and Vascular Conditions
- Vascular Procedures and Complications
- Peripheral Artery Disease Management
- Cardiac Valve Diseases and Treatments
- Cerebrovascular and Carotid Artery Diseases
- Cardiovascular Health and Disease Prevention
- Renal and Vascular Pathologies
- Oropharyngeal Anatomy and Pathologies
- Central Venous Catheters and Hemodialysis
- Diagnosis and Treatment of Venous Diseases
- Intracranial Aneurysms: Treatment and Complications
- Cardiac and Coronary Surgery Techniques
- Dialysis and Renal Disease Management
- COVID-19 and healthcare impacts
- Soft Robotics and Applications
- Abdominal vascular conditions and treatments
- Venous Thromboembolism Diagnosis and Management
- Advanced X-ray and CT Imaging
Ospedale generale di zona San Camillo Treviso
2018-2024
Carlo Forlanini Hospital
2018-2024
Azienda Ospedaliera San Camillo-Forlanini
2021-2023
Ospedale San Filippo Neri
2015-2021
Ospedale Santa Maria alle Scotte
2015-2020
University of Siena
2020
IRCCS San Camillo Hospital
2018
Creative Commons
2015
University of Palermo
2015
University Hospital of Zurich
2015
The aim of this study was to investigate the early outcomes a novel off shelf pre-loaded inner branched thoraco-abdominal endograft (E-nside) in treatment aortic pathologies.Data from physician initiated national multicentre registry on patients treated with E-nside endograft, were prospectively collected and analysed. Pre-operative clinical anatomical characteristics, procedural data, (90 days) recorded dedicated electronic data capture system. primary endpoint technical success. Secondary...
Objective: To assess the initial clinical experience with a novel endograft system (NEXUS Aortic Arch Stent Graft System) designed to treat aortic arch pathologies and address morphology hemodynamic challenges of arch. Summary Background Data: The remains most challenging part aorta for both open endovascular repair. Transcatheter repair has potential significantly reduce surgical risks. Methods: Patients underwent transcatheter single branch, 2 stent graft system, implanted over...
ObjectivesTo report the outcomes of endovascular urgent thoracoabdominal aortic (TAAA) repair, using an off-the-shelf preloaded inner branch device (E-nside, Artivion - Kennesaw, GA – USA).MethodsData from a physician-initiated national multicenter registry, including patients treated with E-nside endograft (INBREED) were prospectively collected (2020-2024); only cases included in this study. Primary technical success and mortality at 30 days. Secondary spinal cord ischemia rate, stroke...
Aortic dissection is a life-threatening vascular disease associated with high rates of morbidity and mortality, especially in medically underserved communities. Understanding patients’ blood flow patterns pivotal for informing evidence-based treatment as they greatly influence the outcome. The present study investigates false lumen three aorta dissections (fully perfused, partially thrombosed, fully thrombosed) chronic phase, compares them to healthy aorta. Three-dimensional geometries...
Abstract OBJECTIVES Endovascular aortic arch stent grafting with branched devices has shown initial promising results. The aim of this prospective, multicentre study was to evaluate 3-year outcomes NEXUS® Aortic Arch Stent Graft System (Nexus), a single-branch, bi-modular, off-the-shelf graft system in high-risk patients. METHODS Patients treated Nexus, either under the feasibility clinical or as compassionate use procedures 5 centres, were included study. primary end point overall survival....
Purpose: To evaluate the outcomes of carotid artery stenting (CAS) with Wallstents in a single-center experience. Methods: From January 2003 to December 2013, 1000 lesions were treated Carotid under cerebral protection 877 patients (mean age 71.7±8 years; 621 men). Indications for treatment de novo (>70% asymptomatic and >60% symptomatic); stenoses following endarterectomy, radiation, or neck surgery; contralateral laryngeal nerve palsy; high surgical risk. All underwent duplex...
To compare outcomes of popliteal artery aneurysm (PAA) repair by endovascular treatment, great saphenous vein (GSV) bypass, and prosthetic bypass. Single center retrospective analysis patients presenting PAA from 2000 to 2013. Patients were divided into treatment (group A); GSV bypass B); graft C). Outcomes technical success, perioperative mortality, morbidity. Survival, primary secondary patency, freedom reintervention rate estimated. Differences in ankle-brachial index (ABI), in-hospital...
The Gore Excluder Iliac Branch Endoprosthesis (IBE) was developed to preserve perfusion in the hypogastric artery after endovascular repair of aorto-iliac aneurysms. This study reports 12 month technical and clinical outcomes treatment with this device.This a physician initiated international multicentre, prospective cohort study. primary endpoint patency branch at months. Secondary endpoints included outcomes. Patients an indication for elective IBE were enrolled between March 2015 August...
Purpose: To assess early and midterm outcomes of iliac branch device (IBD) implantation without an aortic stent-graft for the treatment isolated common artery aneurysm (CIAA). Methods: From December 2006 to June 2016, 49 CIAAs in 46 patients were treated solely with IBD at 7 vascular centers. Five lost follow-up, leaving 41 male (mean age 72.5±7.8 years) analysis. Mean CIAA diameter was 39.1±10.5 mm (range 25–65). Thirty-two (2 bilateral CIAAs) a Cook Zenith device; 9 (1 bilateral) received...
To report our single-center experience in the endovascular treatment of juxtarenal aorto-iliac occlusions.Between December 2008 and 2012, 13 patients with total occlusion, considered at high risk for open revascularization, were treated by means Department. Inclusion criteria severe intermittent claudication, rest pain distal tissue loss. Antegrade recanalization from percutaneous brachial access retrograde angioplasty stenting or surgical femoral accesses performed. The renal arteries (RAs)...
Purpose: To propose a standard measuring protocol for type B aortic dissections so as to improve comparability between studies reporting dimensions. Methods: Fifteen computed tomography (CT) scans of were measured with by 2 independent observers using postprocessing software. The following parameters assessed: true, false, and total lumen diameter; true false volume; entry tear size, location, number. Diameters in perpendicular plane at 2, 10, 20 cm from the left subclavian artery 5 most...
Introduction: The aim of the present study is to report outcome patients presenting an isolated type II endoleak (TIIEL) requiring reintervention and identify clinical anatomical characteristics potentially implicated in refractory TIIEL occurrence fate. Materials Methods: A multicenter retrospective on was conducted between January 2003 December 2020. Demographic characteristics, procedural technical aspects, reinterventions, outcomes were recorded. determining sac expansion greater than 10...
Introduction Staged endovascular treatment of thoracoabdominal aortic aneurysms (TAAA) has been proved to be an effective strategy reduce the risk spinal cord ischemia (SCI). Several techniques have described: some imply staged coverage aorta, other temporarily perfusion sac through a branch left unstented or dedicated that will occluded later. The aim those is facilitate expansion collateral network perfuses cord. However, each them, disadvantages such as need two interventions big...
Cardiovascular disease (CVD) is perhaps the most significant worldwide health issue. While open-heart surgery remains predominant treatment, advancements have been made in minimally invasive (MIS) and robot-assisted (MIRA) surgery. MIRA techniques offer many advantages over procedures extended capabilities of MIS. However, these benefits come at cost increased operating times due to time spent tying knots. The additional bypass limits patient access barrier adoption techniques. This research...