Yuxin Lu

ORCID: 0000-0003-4464-5401
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • High voltage insulation and dielectric phenomena
  • Electrical Fault Detection and Protection
  • High-Voltage Power Transmission Systems
  • HVDC Systems and Fault Protection
  • Thermal Analysis in Power Transmission
  • Advanced Fiber Optic Sensors
  • Malaria Research and Control
  • Power Transformer Diagnostics and Insulation
  • Smart Agriculture and AI
  • Smart Grid and Power Systems
  • Spectroscopy and Chemometric Analyses
  • Transportation and Mobility Innovations
  • Smart Grid Energy Management
  • Computational Drug Discovery Methods
  • Microgrid Control and Optimization
  • Transportation Planning and Optimization
  • Porphyrin and Phthalocyanine Chemistry
  • Trypanosoma species research and implications
  • Power Line Communications and Noise
  • Light effects on plants
  • Railway Systems and Energy Efficiency
  • Electrostatic Discharge in Electronics
  • Advanced Algorithms and Applications
  • Spectroscopy Techniques in Biomedical and Chemical Research
  • Plasma Diagnostics and Applications

Heilongjiang Bayi Agricultural University
2023-2025

China Southern Power Grid (China)
2018-2025

Huazhong University of Science and Technology
2007-2025

Xi'an Jiaotong University
2009-2024

Shanxi University
2024

State Grid Corporation of China (China)
2024

Yibin University
2024

Bengbu Medical College
2024

Guangxi University of Science and Technology
2023

Ministry of Agriculture and Rural Affairs
2023

Abstract Efficient and accurate insulator defect detection is essential for maintaining the safe stable operation of transmission lines. However, effectiveness adversely impacted by complex changeable environmental backgrounds, particularly under extreme weather that elevates accident risks. Therefore, this research proposes a high‐precision intelligent strategy based on synthetic algorithm improved YOLOv7 detecting defects weather. The proposed methodology involves augmenting dataset with...

10.1049/hve2.12513 article EN cc-by High Voltage 2024-12-25

To address the technical challenge of rapid and reliable interruption DC faults in offshore wind power collection transmission systems, which are critical for large-scale renewable energy integration, this paper proposes an integrated multi-port circuit breaker (DCCB) with bus fault clearing capability based on a dual H-bridge configuration. By extending pair bridge arms to connect employing diodes load commutation switches (LCSs) form second H-bridge, proposed DCCB not only achieves...

10.3389/fenrg.2024.1531266 article EN cc-by Frontiers in Energy Research 2025-01-07

Maize, the world’s most widely cultivated food crop, is critical in global security. Low temperatures significantly hinder maize seedling growth, development, and yield formation. Efficient accurate assessment of quality under cold stress essential for selecting cold-tolerant varieties guiding field management strategies. However, existing evaluation methods lack a multimodal approach, resulting inefficiencies inaccuracies. This study combines phenotypic extraction technologies with...

10.3390/agronomy15020254 article EN cc-by Agronomy 2025-01-21

10.1016/j.optlaseng.2025.108956 article EN Optics and Lasers in Engineering 2025-04-03

Abstract Day length modulates hypocotyl elongation in seedlings to optimize their overall fitness. Variations cell growth‐associated genes are regulated by several transcription factors. However, the specific factors through which plant clock increases fitness still being elucidated. In this study, we identified no apical meristem, Arabidopsis thaliana ‐activating factor (ATAF‐1/2), and cup‐shaped cotyledon (NAC) family ATAF1 as a novel repressor of under short‐day (SD) photoperiod. day...

10.1111/pce.14944 article EN Plant Cell & Environment 2024-05-13

Background: Imported cases of infectious disease provide invaluable information about epidemiological conditions abroad, and should guide treatment decisions at home abroad.Here, we examined malaria imported from Africa to China for mutations eroding the efficacy sulfadoxine-pyrimethamine (SP), sometimes used as an intermittent preventive during pregnant women infants.Methods: A total 208 blood samples were collected P. falciparum-infected workers who had returned Western Central Guangxi...

10.1016/j.ijpddr.2019.11.002 article EN cc-by-nc-nd International Journal for Parasitology Drugs and Drug Resistance 2019-11-29

The insulation coordination of the converter station is very important for security and economy UHVDC power transmission system, lightning surge overvoltages at should be calculated accurately. This paper mainly analyzes influence modeling methods on caused by backflashover incoming dc lines using PSCAD program, such as selection stroke current waveform, tower model, flashover criterion insulator, so on. simulation results show that have a great withstand level lines, but their influences...

10.1109/tpwrd.2012.2190306 article EN IEEE Transactions on Power Delivery 2012-06-12

Background: Low-temperature stress significantly restricts maize germination, seedling growth and development, yield formation. However, traditional methods of evaluating quality are inefficient. This study established a method grading based on phenotypic extraction deep learning. Methods: A pot experiment was conducted using different low-temperature combinations treatment durations at six stages between the sowing phases. Changes in 27 indices, including plant morphology photosynthetic...

10.3390/agronomy14040674 article EN cc-by Agronomy 2024-03-26

Plasmodium vivax transmission in West Africa, dominant for the Duffy-negative blood group, has been increasingly recognized from both local residents as well international travelers who contracted P. malaria there. However, relapsing pattern and sensitivity to antimalarial treatment of strains originated this region are largely unknown. There is evidence that efficacy primaquine radical cure depends on host factors such hepatic enzyme cytochrome P450 (CYP) 2D6.A 49-year-old Chinese man was...

10.1186/s12879-019-4357-9 article EN cc-by BMC Infectious Diseases 2019-08-09

The burgeoning demand for enhanced power-system safety means that there is increased attention on technologies the detection and location of cable faults. double-terminal fault method, which senses a current using transformer (CT), most effective widely applied method in industrial practice. However, CT sensors may suffer from magnetic saturation when exposed to high current, resulting significant errors, their sensitivity cannot be adjusted. To address this problem, paper describes an...

10.1109/access.2021.3085298 article EN cc-by IEEE Access 2021-01-01

Partial discharge (PD) detection has proven to be one of the most acceptable techniques for insulation estimation power apparatus. A powerful tool conducting on‐site PD and location in cables is urgently needed. In view this issue, study covers research development efforts design, implement, test a novel damped AC (DAC) system based on frequency‐tuned resonant technique (AC–DAC). This gives cost‐effective solution cables. The topology operation principle proposed are presented described....

10.1049/iet-gtd.2019.1334 article EN IET Generation Transmission & Distribution 2019-10-17

Photodynamic therapy (PDT) agents induce photodamage only where photosensitizers localize in tumor cells. Since apoptosis is a major pathway of PDT-mediated cell death vivo, the therapeutic efficacy PDT drugs against cells may be improved by regulating intrinsic apoptosis. Mitochondria are intracellular organelles that regulate apoptosis, thus triphenylphosphonium, well-known mitochondria-targeting molecule, was appended to photoactive platinum diimine complex. The ability...

10.1080/00958972.2024.2335644 article EN Journal of Coordination Chemistry 2024-03-03

This study covers research and development efforts to develop, design test a novel very low frequency cosine-rectangular voltage generator (CRVG) specialised not only for withstand test, but also partial discharge (PD) of standard medium (MV) cross-linked polyethylene power cables. The system schematic operating principle the proposed are presented described. cosinusoidal polarity reversing process is realised through L –C series resonance. A charging discharging switch developed by means an...

10.1049/iet-gtd.2016.1097 article EN IET Generation Transmission & Distribution 2017-03-29

This research explores the feasibility of extracting plasma molecular temperatures from visible images, an approach aimed at circumventing expensive spectrometer equipment and intricate, time-consuming processes involved in spectral acquisition diagnostics. In our experiment, emission spectrum data needle-plate air discharge under various working conditions are collected, optical spectroscopy (OES) analysis method is employed to diagnose rotational vibrational nitrogen molecules....

10.1109/jsen.2024.3374154 article EN IEEE Sensors Journal 2024-03-18

Hybrid line commutation converter-voltage-source converter high-voltage direct current transmission (LCC-VSC-HVDC) power has unique technical advantages, but its overvoltage study is not sufficient at present. In this study, the typical phenomenon of hybrid LCC-VSC-HVDC analysed and verified by systems computer-aided design/electro-magnetic transient design control simulation. On one hand, mechanism modular multilevel module caused single-phase grounding fault valve side VSC transformer...

10.1049/joe.2018.8729 article EN cc-by-nc-nd The Journal of Engineering 2018-10-26

Summary We have analysed the formation of streak artefacts in reconstruction based on filtered back projection algorithm electron tomography (ET) and accordingly applied an adaptive interpolation technique to artefact reduction. In recover missing information, edge positions a curve were tracked reduce error. A simulation was used demonstrate effectiveness Furthermore, image integrated circuit specimens ET experiments with ultra‐high voltage microscope show that strong can be reduced...

10.1111/j.1365-2818.2009.03357.x article EN other-oa Journal of Microscopy 2009-12-18

High voltage switchgear has been widely used in recent years, meanwhile, electrical faults happen time and again, resulting not only power failure, but also damage to equipment personal safety. Among amounts of faults, insulation take a leading role, which regard partial discharge (PD) signal as an early manifestation, thus PD monitoring is effective method predict fault. This paper designs differential field sensor(D-dot sensor) based on the radio-frequency (RF) technique for on-line...

10.1109/ceidp.2017.8257610 article EN 2017-10-01