- Cardiac Valve Diseases and Treatments
- Coronary Interventions and Diagnostics
- Vascular Procedures and Complications
- Cardiac pacing and defibrillation studies
- Cardiac Structural Anomalies and Repair
- Hemostasis and retained surgical items
- Venous Thromboembolism Diagnosis and Management
- Cardiovascular and Diving-Related Complications
- Electrospun Nanofibers in Biomedical Applications
- Integrated Circuits and Semiconductor Failure Analysis
- Dialysis and Renal Disease Management
- Neuroscience of respiration and sleep
- Cardiovascular Syncope and Autonomic Disorders
- Cardiac Imaging and Diagnostics
- Pulmonary Hypertension Research and Treatments
- Antiplatelet Therapy and Cardiovascular Diseases
- Cardiovascular Function and Risk Factors
- Aortic aneurysm repair treatments
- Infective Endocarditis Diagnosis and Management
- Cardiac Arrhythmias and Treatments
Vita-Salute San Raffaele University
2022-2024
Istituto di Ricovero e Cura a Carattere Scientifico San Raffaele
2022-2024
Clinique Pasteur
2017-2018
Hôpital Rangueil
2014
University of Milan
2010-2014
Centro Cardiologico Monzino
2011
Valve-in-ring procedures represent a feasible solution for high-risk patients with surgical repair failure. The risk of left ventricular outflow tract obstruction increases the challenge, and transcatheter approaches to prevent it are technically demanding often do not resolve it. We demonstrate feasibility safety transseptal balloon-assisted translocation anterior mitral leaflet valve-in-ring implantation.
This single-center, observational, prospective study evaluated the impact of patent foramen ovale (PFO) closure on migraine attacks over time.PFO may reduce frequency and severity headaches in patients with significant right-to-left shunts.Between May 2000 September 2009, 305 consecutive (mean age, 43 ± 12 years; 54.5% women) a prior embolic cerebrovascular event underwent PFO Amplatzer occluder for recurrence prevention. All had shunts; shunts were associated symptoms 77 (25%), either alone...
Severe mitral insufficiency is a feared complication that develops in 10-12% of patients with myocardial infarction and ST elevation. It results from the rupture papillary muscle or secondary to an acute remodelling left ventricle its entirety infarcted region. The mortality clinical onset reaches 50%. ideal treatment controversial still source debate. Most these are at high surgical risk inoperable; therefore, they treated conservatively have poor prognosis. In candidates, percutaneous edge...
Coronary artery disease affects over 5,000,000 people worldwide. Despite technology evolution and extension of indications drug-eluting bioresorbable stents, bare-metal stents play an important role to treat single lesions less than 15 mm length and/or greater 2.5 diameter. The REBEL™ stent is made from a new platinum–chromium alloy combined with customized architecture enhanced delivery system that allows improved performances this such as high radial axial strength lower recoil....
We report a case of patient with single-chamber Hisian pacemaker who developed complete atrioventricular block and significant deterioration the ventricular threshold sensing after transcatheter aortic valve replacement. Revision implantation was required, lead extraction