- Advanced X-ray and CT Imaging
- Cardiac Imaging and Diagnostics
- Radiation Dose and Imaging
- Radiomics and Machine Learning in Medical Imaging
- Medical Imaging Techniques and Applications
- Advanced MRI Techniques and Applications
- Radiology practices and education
- Lung Cancer Diagnosis and Treatment
- Cardiac Structural Anomalies and Repair
- COVID-19 diagnosis using AI
- Nutrition and Health in Aging
- Cardiovascular Function and Risk Factors
- Artificial Intelligence in Healthcare and Education
- Frailty in Older Adults
- Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
- Mechanical Circulatory Support Devices
- Medical Imaging and Pathology Studies
- Cerebrovascular and Carotid Artery Diseases
- Cardiomyopathy and Myosin Studies
- IgG4-Related and Inflammatory Diseases
- Lung Cancer Treatments and Mutations
- Congenital Heart Disease Studies
- Ultrasound in Clinical Applications
- Cardiac Valve Diseases and Treatments
- Esophageal and GI Pathology
Medical University of South Carolina
2020-2025
Medical College of Wisconsin
2013-2024
Siemens (Germany)
2024
Ludwig-Maximilians-Universität München
2024
German Centre for Cardiovascular Research
2024
Johannes Gutenberg University Mainz
2024
Aurora Health Care
2021
Jacksonville College
2021
Mayo Clinic in Florida
2021
WinnMed
2021
Background Photon-counting detector (PCD) CT provides comprehensive spectral data with every acquisition, but studies evaluating myocardial extracellular volume (ECV) quantification use of PCD compared an MRI reference remain lacking. Purpose To compare ECV for tissue characterization between a first-generation system and cardiac MRI. Materials Methods In this single-center prospective study, adults without contraindication to iodine-based contrast media underwent same-day native...
The aim of this study was to evaluate the impact virtual monoenergetic imaging (VMI) and quantum iterative reconstruction (QIR) on accuracy coronary artery calcium scoring (CACS) using a noniodine (VNI) algorithm first-generation, clinical, photon counting detector computed tomography system.Coronary evaluated in an anthropomorphic chest phantom simulating 3 different patient sizes by 2 extension rings (small: 300 × 200 mm, medium: 350 250 large: 400 mm) patients (n = 61; final analyses only...
Please see the Editorial Comment by Edwin F. Donnelly discussing this article.
To compare coronary artery calcium volume and score (CACS) between photon-counting detector (PCD) conventional energy integrating (EID) computed tomography (CT) in a phantom prospective patient study. A commercially available CACS was scanned with standard protocol (120 kVp, slice thickness/increment 3/1.5 mm, quantitative Qr36 kernel), filtered back projection on the EID-CT, monoenergetic reconstruction at 70 keV quantum iterative off PCD-CT. The same settings were used to prospectively...
Photon-counting detector computed tomography (PCD-CT) may influence imaging characteristics for various clinical conditions due to higher signal and contrast-to-noise ratio in virtual monoenergetic images (VMI). Radiomics analysis relies on quantification of image characteristics. We evaluated the impact different VMI reconstructions radiomic features vitro vivo PCD-CT datasets.An organic phantom consisting twelve samples (four oranges, four onions, apples) was scanned five times....
This study aimed to evaluate the accuracy and efficiency of ChatGPT-3.5, ChatGPT-4o, Google Gemini, Gemini Advanced in generating CAD-RADS scores based on radiology reports. retrospective analyzed 100 consecutive coronary computed tomography angiography reports performed between March 15, 2024, April 1, at a single tertiary center. Each report containing radiologist-assigned score was processed using four large language models (LLMs) without fine-tuning. The findings section each input into...
Introduction: Myocardial viability refers to a phenomenon in which dysfunctional myocardium, due acute or chronic ischaemia, retains the potential recover its systolic function after revascularisation. The assessment of myocardial using Contrast-enhanced Magnetic Resonance Imaging (CEMRI) has become quintessential imaging method for guidance treatment patients with Infarction (MI). Aim: To assess cardiac morphology, function, perfusion and ischaemic heart disease, stratify into conservative...
Over one-half of all cancer patients receive radiation therapy (RT). However, exposure to the heart can cause cardiotoxicity. Nevertheless, there is a paucity data on RT-induced cardiac damage, with limited understanding safe regional RT doses, early detection, prevention, and management. A common initial feature cardiotoxicity asymptomatic dysfunction, which, if left untreated, may progress failure. The current paradigm for detection management relies primarily upon assessment ejection...
Airspace disease as seen on chest X-rays is an important point in triage for patients initially presenting to the emergency department with suspected COVID-19 infection. The purpose of this study evaluate a previously trained interpretable deep learning algorithm diagnosis and prognosis pneumonia from obtained ED.This retrospective included 2456 (50% RT-PCR positive COVID-19) adult who received both X-ray SARS-CoV-2 test January 2020 March 2021 at single U.S.A total 2000 were additional...
Abstract Tuberculosis of the orbit is rare, even in places where tuberculosis endemic. The disease may involve soft tissue, lacrimal gland, or periosteum bones orbital wall. Intracranial extension, form extradural abscess, and infratemporal fossa extension has been described. This pictorial essay illustrates imaging findings nine histopathologically confirmed cases tuberculosis. All these patients responded to antituberculous treatment.
Cardiac myxoma is the most common primary cardiac neoplasm. It a benign tumor that typically arises in left atrium, specifically from interatrial septum adjacent to fossa ovalis. We present case of 71-year-old male presenting with hematuria was incidentally found have atrial on CT urogram. Follow-up and MRI heart demonstrated findings compatible myxoma. Cardiothoracic surgery consulted, patient underwent resection mass, which confirmed be pathology.
Purpose To investigate the impact of plaque size and density on virtual noncontrast (VNC)-based coronary artery calcium scoring (CACS) using photon-counting detector CT to provide safety net reconstructions for improved detection subtle plaques in patients whose VNC-based CACS would otherwise be erroneously zero when compared with true (TNC)-based CACS. Materials Methods In this prospective study, was evaluated a phantom containing calcifications different diameters (5, 3, 1 mm) densities...