Joachim Graessner

ORCID: 0000-0001-6567-7432
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Advanced MRI Techniques and Applications
  • MRI in cancer diagnosis
  • Salivary Gland Tumors Diagnosis and Treatment
  • Advanced Neuroimaging Techniques and Applications
  • Cardiac Imaging and Diagnostics
  • Radiomics and Machine Learning in Medical Imaging
  • Hemoglobinopathies and Related Disorders
  • Atomic and Subatomic Physics Research
  • Cerebrovascular and Carotid Artery Diseases
  • Fetal and Pediatric Neurological Disorders
  • Cardiovascular Function and Risk Factors
  • Salivary Gland Disorders and Functions
  • Renal and Vascular Pathologies
  • Aortic Disease and Treatment Approaches
  • Iron Metabolism and Disorders
  • Bone Tumor Diagnosis and Treatments
  • Medical Imaging Techniques and Applications
  • Congenital Heart Disease Studies
  • Aortic aneurysm repair treatments
  • Prostate Cancer Diagnosis and Treatment
  • Vascular Procedures and Complications
  • Cardiovascular Health and Disease Prevention
  • Ophthalmology and Eye Disorders
  • Cardiac pacing and defibrillation studies
  • Oral and Maxillofacial Pathology

Siemens Healthcare (Germany)
2010-2024

Universität Hamburg
2004-2016

Siemens (Germany)
2004-2015

Philips (Germany)
2012

University Medical Center Hamburg-Eppendorf
2004-2009

University of Regensburg
2009

Medical Solutions
2005-2009

Eppendorf (Germany)
2007-2008

University Hospital Schleswig-Holstein
2007

University of Lübeck
2007

<b>BACKGROUND AND PURPOSE:</b> Our aim was to determine the value of echo-planar diffusion-weighted MR imaging (epiDWI) in differentiating various types primary parotid gland tumors. <b>MATERIALS METHODS:</b> One hundred forty-nine consecutive patients with suspected tumors were examined an epiDWI sequence by using a 1.5T unit. Image analysis performed 2 radiologists independently, and intraclass correlation coefficient computed. Histologic diagnosis obtained every patient. For comparison...

10.3174/ajnr.a1412 article EN cc-by American Journal of Neuroradiology 2009-01-08

Different software programs are available for the evaluation of 4D Flow cardiovascular magnetic resonance (CMR). A good agreement results between is a prerequisite acceptance method. Therefore, goal was to compare quantitative from cross-over comparison in individuals examined on two scanners different vendors analyzed with four postprocessing packages. Eight healthy subjects (27 ± 3 years, women) were each 3T CMR systems (Ingenia, Philips Healthcare; MAGNETOM Skyra, Siemens Healthineers)...

10.1186/s12968-023-00921-4 article EN cc-by Journal of Cardiovascular Magnetic Resonance 2023-02-01

To investigate the feasibility of using diffusion-weighted (DW) echo-planar imaging (EPI) for differentiating primary parotid gland tumors.Fifty consecutive patients with a suspected tumor were examined DW EPI sequence (TR 1,500 msec, TE 77 field view 250 x mm, pixel size 2.10 1.95 section thickness 5 mm). The b factors used 0, 500, and 1,000 sec/mm (2). Apparent diffusion coefficient (ADC) maps digitally transferred to MRIcro (Chris Rorden, University Nottingham, Great Britain) evaluated...

10.1055/s-2005-858297 article EN RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren 2005-06-22

PURPOSE: To optimize and determine the value of dual-phase contrast material–enhanced three-dimensional (3D) magnetic resonance (MR) angiography for preoperative evaluation blood supply to liver. MATERIALS AND METHODS: Dual phase 3D MR hepatic arteries portal vein was performed in 140 patients. In 80 patients, fat saturation, digital image subtraction, an anticholinergic agent, a high-caloric meal were evaluated. next 60 angiographic subtraction (DSA) quality diagnostic compared. RESULTS:...

10.1148/radiology.211.1.r99mr2251 article EN Radiology 1999-04-01

PURPOSE: To prospectively evaluate the clinical feasibility of magnetic resonance (MR) imaging lungs with fast volumetric interpolated three-dimensional (3D) gradient-recalled-echo (GRE) sequences and to compare this examination standard computed tomography (CT) in patients lung abnormalities. MATERIALS AND METHODS: Twenty-five different abnormalities were examined 3D GRE MR imaging. The small pulmonary nodules seven, TNM stage large intrapulmonary tumors eight, benign bronchial disease five...

10.1148/radiol.2261011974 article EN Radiology 2003-01-01

Abstract Purpose: To evaluate differences in apparent diffusion coefficient (ADC) values between head, body, and tail regions the impact of sets b‐values used weighted imaging (DWI) normal pancreas. Materials Methods: In 51 healthy volunteers echo‐planar DWI pancreas was prospectively performed with 50, 400, 800 s/mm 2 . All four possible combinations were to calculate ADC a total 587 regions. Dependency on anatomical applied calculated using multivariate analysis variance (ANOVA). Results:...

10.1002/jmri.22743 article EN Journal of Magnetic Resonance Imaging 2011-08-11

To determine the pancreatic iron (R2*) and fat content (FC) in comparison to hepatic cardiac R2* patients with overload disorders like β-thalassemia major (TM), Diamond-Blackfan anemia (DBA) or hereditary hemochromatosis.R2* rates were assessed liver, heart pancreas of 42 TM, 29 subjects other diseases, 10 controls using an ECG-gated breathhold sequence (12 echo time [TE] = 1.3-25.7 ms, readout repetition [TR] 244 ms). Pancreatic FC from TE dependent region interest based signal intensities...

10.1002/jmri.24752 article EN Journal of Magnetic Resonance Imaging 2014-09-19

Magnetic resonance (MR) sequences for cartilage visualization have been the target of numerous studies, and optimal sequence imaging remains a matter debate in literature.To compare MR findings with different detection lesions fresh deep-frozen human cadaveric patellae an vitro setting.Ten were imaged on 1.5T scanner 2x2 channel carotid sandwich coil conventional knee coil, compared orthopedic gold-standard histopathology. were: a) fat-saturated (FS) proton density-weighted (PDw) turbo...

10.1080/02841850701549583 article EN Acta Radiologica 2007-11-27

Purpose: To retrospectively evaluate the impact of diffusion-weighted imaging (DWI) on detection prostate cancer in comparison with sextant biopsy. Materials and Methods: Fifty patients clinical suspicion underwent a combined endorectal-body-phased array magnetic resonance examination at 1.5 T (Siemens, Erlangen, Germany). The DWI was performed using b values 50, 400, 800 s/mm2. divided into sextants, including apex, middle aspect, base for left right sides, separately. Regions interest were...

10.1097/rct.0b013e3181fc5409 article EN Journal of Computer Assisted Tomography 2011-03-01

Abstract Purpose: To investigate the healthy pancreas with diffusion‐weighted imaging (DWI) for characterization of age and gender‐related differences in apparent diffusion coefficient (ADC) values. Materials Methods: Sixty six volunteers were prospectively enrolled (33 male, 33 female; range 1.4 to 83.7 years age) echo‐planar DWI was performed. ADC values measured head, body, tail using a pixel‐by‐pixel approach. Effects gender on analyzed two‐factorial multivariate analysis variance...

10.1002/jmri.23871 article EN Journal of Magnetic Resonance Imaging 2012-10-19

To evaluate the efficacy of contrast material-enhanced magnetic resonance (MR) angiography for diagnosis peripheral arterial occlusion and follow-up after stent placement.Sixty-seven patients (21 women, 46 men; mean age, 64.6 years) were examined. Digital subtraction contrast-enhanced MR performed in 28 preinterventional evaluation iliofemoral 39 placement iliac or femoral arteries, which had been several months before.All 24 occlusions correctly diagnosed with angiography. Of 59 stenoses,...

10.1148/radiology.212.2.r99au24371 article EN Radiology 1999-08-01

<b>BACKGROUND AND PURPOSE:</b> Our aim was to compare different field strengths monitoring physiologic changes due oral stimulation of parotid glands by using diffusion-weighted (DW) echo-planar imaging (EPI). <b>MATERIALS METHODS:</b> Twenty-seven healthy volunteers were examined with a DW-EPI sequence at 1.5T and 3T before after commercially available lemon juice. The b factors used 0, 500, 1000 s/mm<sup>2</sup>. Apparent diffusion coefficient (ADC) maps evaluated manually placed region...

10.3174/ajnr.a0587 article EN cc-by American Journal of Neuroradiology 2007-09-01

Ziel: Den Stellenwert der diffusionsgewichteten echoplanaren Bildgebung (DW-EPI) zur Quantifizierung funktionaler Veränderungen Glandula parotidea in Diagnostik des Morbus Sjögren zu bestimmen und evaluieren, ob mittels ADC-Messung eine Diagnosefindung im Frühstadium möglich ist. Material Methoden: Es wurden 52 gesunde Probanden 13 Patienten mit histologisch gesicherter Sjögren-Erkrankung einer DW-EPI Sequence (B-Faktoren: 0, 500 1000 s/mm2) bei 1,5 Tesla untersucht. Die Bildakquisition...

10.1055/s-0028-1109105 article DE RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren 2009-02-19

Objective: To evaluate the feasibility of a magnetic resonance imaging protocol for lung using volumetric interpolated 3D-gradient echo sequence (3D-GRE). Subjects and Methods: A T1-weighted 3D-GRE was used breath-hold examinations (“VIBE”) in twelve healthy volunteers (TR/TE 4.5/1.9 ms, flip-angle 12°, matrix 502 × 512 [interpolated]). Three coronal 80 mm slabs (16 partitions, 2.5 slices) were added to 3D data sets multi-planar reformations. No contrast material applied. Artifacts...

10.1055/s-2001-17585 article EN RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren 2001-10-04

Ziel: Evaluation der diffusionsgewichteten echoplanaren MRT zur Messung unterschiedlicher Funktionszustände Glandula parotidea und Vergleich verschiedener Auswertemethoden. Material Methoden: Ohrspeicheldrüsen von 27 gesunden Probanden wurden mit einer MR-Sequenz (TR = 1.500 ms, TE 77 Sichtfenster („field-of-view”) 250 mm2, Pixelgröße 2,10 × 1,95 mm, Schichtdicke 5 mm) vor nach oraler Gabe eines kommerziell erhältlichen Zitronensaftes untersucht. Die benutzten b-Werte betrugen 0 sec/mm2, 500...

10.1055/s-2004-813564 article DE RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren 2004-09-22

Ziel: Untersuchung zur Wertigkeit der MRT in Verlaufskontrolle bei Patienten mit d-TGA nach Switch-Operation. Material und Methoden: 14 konsekutive (Alter 4 bis 20 Jahre, Durchschnitt 13,5) arterieller Switch-Operation (ASO) Dextro-Transposition großen Gefäße (d-TGA) wurden unzureichendem echokardiographischen Schallfenster untersucht. 9 hatten eine ASO Pulmonalarterienbifurkation vor Aortenwurzel (Kollektiv 1), 5 lateral (2 links, 3 rechts) gelegener 2) erhalten. Die erfolgte 6...

10.1055/s-2005-858122 article DE RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren 2005-01-01
Coming Soon ...