Juliane Goebel

ORCID: 0000-0001-7481-0565
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Cardiac Imaging and Diagnostics
  • Advanced MRI Techniques and Applications
  • Acute Ischemic Stroke Management
  • Cerebrovascular and Carotid Artery Diseases
  • Cardiovascular Function and Risk Factors
  • Radiomics and Machine Learning in Medical Imaging
  • Viral Infections and Immunology Research
  • Atomic and Subatomic Physics Research
  • Medical Imaging Techniques and Applications
  • Cardiomyopathy and Myosin Studies
  • Hepatocellular Carcinoma Treatment and Prognosis
  • Hepatitis B Virus Studies
  • Clostridium difficile and Clostridium perfringens research
  • Intracerebral and Subarachnoid Hemorrhage Research
  • Infective Endocarditis Diagnosis and Management
  • Medical Device Sterilization and Disinfection
  • Bone and Joint Diseases
  • Muscle Physiology and Disorders
  • Lymphoma Diagnosis and Treatment
  • Cardiac Valve Diseases and Treatments
  • Orthopedic Infections and Treatments
  • Traumatic Brain Injury and Neurovascular Disturbances
  • MRI in cancer diagnosis
  • Blood Coagulation and Thrombosis Mechanisms
  • Lung Cancer Diagnosis and Treatment

University of Duisburg-Essen
2016-2024

Essen University Hospital
2016-2022

Society of Interventional Radiology
2020

Erwin L. Hahn Institute for Magnetic Resonance Imaging
2017

<h3>BACKGROUND AND PURPOSE:</h3> Detailed insight into the composition of thrombi retrieved from patients with ischemic stroke by mechanical thrombectomy might improve pathophysiologic understanding and therapy. Thus, this study searched for links between histologic thrombus subtypes results. <h3>MATERIALS METHODS:</h3> Thrombi 85 who had undergone acute December 2016 March 2018 were studied retrospectively. examined histologically. Preinterventional imaging features, subtypes,...

10.3174/ajnr.a6467 article EN cc-by American Journal of Neuroradiology 2020-03-19

Objectives T1 mapping allows quantitative myocardial assessment, but its value in clinical routine remains unclear. We investigated, whether the average native can be used as a diagnostic classifier between healthy and diffuse diseased myocardium. Methods Native was performed 54 persons with hearts 150 patients pathologies (coronary artery disease (CAD): n = 76, acute myocarditis: 19, convalescent 26, hypertrophic cardiomyopathy (HCM): 12, dilated (DCM): 17) at 1.5 Tesla mid-ventricular...

10.1371/journal.pone.0155591 article EN cc-by PLoS ONE 2016-05-24

To assess two compressed sensing cine magnetic resonance imaging (MRI) sequences with high spatial or temporal resolution in comparison to a reference steady-state free precession (SSFP) sequence for reliable quantification of left ventricular (LV) volumes.LV short axis stacks breath-hold (SPARSE-SENSE HS: resolution: 40 msec, in-plane 1.0 × mm(2) ) and HT: 11 1.7 SSFP (standard SSFP: were acquired 16 healthy volunteers on 1.5T MR system. LV parameters analyzed semiautomatically twice by one...

10.1002/jmri.25162 article EN Journal of Magnetic Resonance Imaging 2016-01-20

Radioembolization for the treatment of hepatocellular carcinoma (HCC) induces liver volume changes referred to as "atrophy-hypertrophy complex". The aim this study was investigate lobar after unilateral radioembolization and search factors associated with hypertrophy untreated lobe.Seventy-five patients were retrospectively evaluated. Inclusion criteria were: (1) right-lobar unresectable HCC, (2) available computed tomography scans before, 1, 3, at least 6 months radioembolization. Baseline...

10.1371/journal.pone.0181488 article EN cc-by PLoS ONE 2017-07-14

Background Cardiac magnetic resonance imaging (MRI) relies on correct ECG-gating, which is hindered in arrhythmia. Purpose To examine whether a prototype free-breathing real-time cine sequence using SPARSE-SENSE (SPARSE) improves left ventricular quantification atrial fibrillation. Material and Methods On 1.5T MR system short-axis stacks were acquired of the SPARSE “reference” steady-state free precession (SSFP) with arrhythmia rejection 20 patients Two radiologists independently rated...

10.1177/0284185116681037 article EN Acta Radiologica 2016-12-13

Introduction The objective of this study was to assess the diagnostic value integrated 11C- methionine PET/MRI for suspected primary brain tumors, in comparison MRI alone. Material and Methods Forty-eight consecutive patients with tumor were prospectively enrolled an 11C-methionine PET/MRI. Two neuro-radiologists separately evaluated alone data sets regarding most likely diagnosis confidence on a 5-point scale. Reference standard histopathology or follow-up imaging. Results Fifty-one...

10.1371/journal.pone.0167596 article EN cc-by PLoS ONE 2016-12-01

Purpose A prerequisite for cardiac MR (CMR) imaging is adequate synchronization of image acquisition with the cycle. Electrocardiogram triggering may be hampered by electromagnetic interferences at high field strength. The purpose this work to evaluate feasibility Doppler ultrasound CMR 7T ultra‐high‐field MRI. Methods custom‐built (DUS) trigger device was developed. Magnetic resonance compatibility evaluated using E‐ and H‐field probes flip angle maps prior study. Cardiac performed in 13...

10.1002/mrm.27032 article EN Magnetic Resonance in Medicine 2017-12-01

Aim: To quantify the frequency of bacterial contamination injected contrast agent/saline solution by an automated injection system, and to evaluate whether usage a novel tube system can reduce it. Methods: For quantification two identical piston pump MRI injectors were used in combination with standard system. 3-5 ml was collected from prior its connection patients' venous cannula 104 consecutive patients. test, reduces contamination, shielded screw connections same samples further 101...

10.3205/dgkh000321 article EN DOAJ (DOAJ: Directory of Open Access Journals) 2019-01-01

Background Computer-aided diagnosis is increasingly used in radiology and may support not only unexperienced readers but also senior radiologists. It appears promising, especially the sometimes challenging detection of early ischemic changes stroke CT. Purpose To compare new post-processing software prototype Frontier_ASPECTS against two radiologists ASPECTS evaluation. Material Methods Retrospectively, pre-interventional CTs 100 patients, who underwent endovascular revascularization for...

10.1177/0284185119842465 article EN Acta Radiologica 2019-04-24

Transarterial chemoembolization (TACE) is currently the standard of care in patients with unresectable hepatocellular carcinoma (HCC), and selective internal radionuclide therapy (SIRT) 90Y microspheres mainly used as an alternative modality considered poor candidates for TACE. Treatment sorafenib recommended option progressive disease after This study aims to evaluate safety efficacy SIRT glass HCC repeated TACE who are not eligible treatment sorafenib. Forty-seven a median three sessions...

10.3390/ph17010101 article EN cc-by Pharmaceuticals 2024-01-11

This study examined the feasibility of aortic valve planimetry at 7 T ultrahigh field MRI in intraindividual comparison to 3 and 1.5 MRI.Aortic valves eleven healthy volunteers (mean age, 26.4 years) were on a T, MR system using FLASH TrueFISP sequences. Two experienced radiologists evaluated overall image quality, presence artefacts, tissue contrast ratios, identifiability, details opening area (AVOA). Furthermore, AVOA was quantified twice by reader 1 once 2. Correlation analysis between...

10.1016/j.ejro.2018.08.008 article EN cc-by-nc-nd European Journal of Radiology Open 2018-01-01

In muscular dystrophies, it is not only skeletal muscles that can be affected, but also the myocardium. This cardiac involvement represent a major cause of morbidity and mortality.To investigate in Duchenne (DMD), Becker (BMD), limb girdle dystrophy (LGMD) patients, carriers DMD/BMD by magnetic resonance (CMR) imaging to search for differences pattern involvement.All patients with genetically or histologically proven DMD, BMD, LGMD, confirmed who had undergone CMR at our clinic between...

10.1177/02841851221077402 article EN Acta Radiologica 2022-02-11

Background: Recently faster cardiac magnetic resonance (CMR) cine sequences basing on k-t compressed sensing have been developed. Purpose: To compare two CMR sequences-one in breath-hold technique and one during free breathing—with the standard SSFP sequence with respect to regional left ventricular function assessment. Material Methods: Left short-axis stacks of (sparse_HB) breathing (sparse_FB; both spatial resolution, 1.8 × 8 mm3) a (spatial 1.9 were acquired 50 patients 1.5 T MR system....

10.4236/wjcd.2018.86027 article EN World Journal of Cardiovascular Diseases 2018-01-01
Coming Soon ...