- Neuroscience and Neural Engineering
- Advanced Sensor and Energy Harvesting Materials
- Nerve injury and regeneration
- Electrospun Nanofibers in Biomedical Applications
- Photoreceptor and optogenetics research
- Planarian Biology and Electrostimulation
- Advanced Memory and Neural Computing
- Remote Sensing and Land Use
- Conducting polymers and applications
- Tissue Engineering and Regenerative Medicine
- Anesthesia and Neurotoxicity Research
- Anesthesia and Sedative Agents
- Muscle activation and electromyography studies
- Nuclear Materials and Properties
- Metal Extraction and Bioleaching
- Blood transfusion and management
- Korean Urban and Social Studies
- Advanced Battery Technologies Research
- Minerals Flotation and Separation Techniques
- Nanowire Synthesis and Applications
- Environmental remediation with nanomaterials
- Graphene and Nanomaterials Applications
- Modular Robots and Swarm Intelligence
- Advanced battery technologies research
- Hematopoietic Stem Cell Transplantation
Beihang University
2022-2025
Beijing Advanced Sciences and Innovation Center
2025
Zhejiang International Studies University
2025
Army Medical University
2021
Tsinghua University
2017-2020
State Key Laboratory of New Ceramics and Fine Processing
2018-2020
Jilin University
2016
Tongji University
2014
Henan University of Science and Technology
2014
National University of Defense Technology
2013
Implantable chemical sensors built with flexible and biodegradable materials exhibit immense potential for seamless integration biological systems by matching the mechanical properties of soft tissues eliminating device retraction procedures. Compared conventional hospital-based blood tests, implantable have capability to achieve real-time monitoring high accuracy important biomarkers such as metabolites, neurotransmitters, proteins, offering valuable insights clinical applications. These...
Monitoring the early-stage healing of severe traumatic nerve injuries is essential to gather physiological and pathological information for timely interventions optimal clinical outcomes. Traditional diagnostic methods relying on physical examinations, imaging tools, intraoperative electrophysiological testing present great challenges in continuous remote monitoring. While implantable peripheral interfaces provide direct access fibers precise interrogation modulation, conventional...
A biodegradable and self-electrified conduit device is achieved to offer postoperative electrical cues for nerve regeneration.
Given the advantages of high energy density and easy deployment, biodegradable primary battery systems remain as a promising power source to achieve bioresorbable electronic medicine, eliminating secondary surgeries for device retrieval. However, currently available biobatteries are constrained by operational lifetime, biocompatibility, biodegradability, limiting potential therapeutic outcomes temporary implants. Herein, we propose fully zinc–molybdenum (Zn–Mo) with prolonged functional...
Abstract Optoelectronic neural interfaces can leverage the photovoltaic effect to convert light into electrical current, inducing charge redistribution and enabling nerve stimulation. This method offers a non-genetic remote approach for neuromodulation. Developing biodegradable efficient optoelectronic is important achieving transdermal stimulation while minimizing infection risks associated with device retrieval, thereby maximizing therapeutic outcomes. We propose biodegradable, flexible,...
Peripheral nerve injury represents one of the most common types traumatic damage, severely impairing motor and sensory functions, posttraumatic regeneration remains a major challenge. Electrical cues are critical bioactive factors that promote regrowth, bioartificial scaffolds incorporating conductive materials to enhance endogenous electrical field have been demonstrated be effective. The utilization fully biodegradable can eliminate material residues, circumvent need for secondary...
Biodegradable electronic devices that physically disappear in physiological or environmental solutions are of critical importance for widespread applications healthcare management and sustainability. The precise modulation materials dissolution with on-demand operational lifetime, however, remain a key challenge. Silicon nanomembranes (Si NMs) one the essential semiconductor components high-performance biodegradable electronics at system level. In this work, we discover unusual hydrolysis...
A well-designed mesh configuration is of great importance to the performance large cable-network antenna reflectors. The motivation this study find a general approach for designing appropriate configurations such reflector structure. By synthetically considering shape-forming criteria, boundary connection conditions, and surface dividing ways, versatile with ability generate desired spatial parabolic specific engineering significance proposed. In paper, three criteria based on force-density...
Data security risks of unauthorized access confidential information have attracted considerable attention. Transient electronics capable physical disappearance or disintegration upon external stimuli could potentially offer an alternative solution at the device level. Despite great advances, smart, efficient, wireless, and nonrecoverable degradation foundry‐compatible silicon (Si)‐integrated circuit (IC) chips remains a challenge. Herein, laser‐triggered Si circuits by lithiation moisture...
Leukocytes have an essential role in patient clinical trajectories and progression. Traditional methods of leukocyte enrichment many significant limitations for current applications. It is demonstrated a novel 3D printing sorting accumulator that combines with centrifugation to ensure label-free initial based on cell density size. The internal structure (revealed here new design, accumulator-3, upgraded from earlier models), optimizes localization the buffy coat fraction length period...
This document bases on settlement observation of a residential district which is influenced by the subway construction in Shanghai China.Because long-term measurement,there were some equipment boxes installed top marks.Thus making leveling rod an leaning angle to right or left direction relative sight line.In order know error measurement,we make analysis error.And it also can be reference for other surveyings when encounter this similar circumstance.
The cold storage temperature in China is required at-18°C. At the temperature, microbial breeding almost completely stopped, biochemical changes are greatly suppressed food. However, evaporator surface will frost easily at low temperature. Because of high thermal resistance layer, heat transfer effect becomes worse. It also led to decrease evaporation power consumption refrigeration unit increases and dry food huge. Therefore experiment research exchanger a certain air wind speed, relative...
It is more and concerned after Fukushima Daiichi about spent fuel pool severe accident management, it also required by the regulatory body of NSC (Nuclear Radiation Safety Center). During such a beyond design basis event, assembly becomes over-heated finally damaged. In order to prevent stop SFP (spent pool) process, strategies should be developed when existing procedures are no longer effective or available. This paper gives development approach CPR1000 NPP (nuclear power plant) management...