Mariano De Prado

ORCID: 0000-0002-1455-0148
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Foot and Ankle Surgery
  • Tendon Structure and Treatment
  • Orthopedic Surgery and Rehabilitation
  • Dark Matter and Cosmic Phenomena
  • Diabetic Foot Ulcer Assessment and Management
  • Peripheral Nerve Disorders
  • Musculoskeletal synovial abnormalities and treatments
  • Particle Detector Development and Performance
  • Lower Extremity Biomechanics and Pathologies
  • Radiation Therapy and Dosimetry
  • Atomic and Subatomic Physics Research
  • CCD and CMOS Imaging Sensors
  • Hip disorders and treatments
  • Radiation Detection and Scintillator Technologies
  • Botulinum Toxin and Related Neurological Disorders
  • Nail Diseases and Treatments
  • Bone and Joint Diseases
  • Shoulder Injury and Treatment
  • Diagnosis and Treatment of Venous Diseases
  • Radiation Effects and Dosimetry
  • Medical research and treatments
  • French Urban and Social Studies
  • Advanced Radiotherapy Techniques
  • Neutrino Physics Research
  • Nerve Injury and Rehabilitation

Hospital Ruber Internacional
2025

Hospital for Special Surgery
2025

Hospital Clínico San Carlos
2003-2022

Hospital Quirónsalud Barcelona
2022

Servicio Murciano de Salud
2022

Paul Scherrer Institute
2015-2020

Universidad Complutense de Madrid
2009-2015

Universitat de Barcelona
2015

Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas
2009-2011

Clinique du Sport
2009

To optimise the design of light readout in ArDM 1-ton liquid argon dark matter detector, a range reflector and WLS coating combinations were investigated several small setups, where scintillation was generated by radioactive sources gas at normal temperature pressure shifted into blue region tetraphenyl butadiene (TPB). Various thicknesses TPB deposited spraying vacuum evaporation onto specular 3M{\small\texttrademark}-foil diffuse Tetratex{\small\textregistered} (TTX) substrates. Light...

10.1088/1748-0221/4/06/p06001 article EN Journal of Instrumentation 2009-06-01

The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct searches. Such device allows to explore the low energy frontier in LAr with charge imaging detector. ionization extracted from into gas phase and there amplified by use of Large Electron Multiplier order reduce detection threshold. Direct fine spatial granularity, combined measurement amplitude evolution associated primary scintillation light, provide powerful...

10.1088/1742-6596/308/1/012006 article EN Journal of Physics Conference Series 2011-07-25

10.1016/j.fuspru.2013.02.007 article EN Fuß & Sprunggelenk 2013-04-02

ArDM-1t is the prototype for a next generation WIMP detector measuring both scintillation light and ionization charge from nuclear recoils in 1-ton liquid argon target. The goal to reach minimum recoil energy of 30 keVr detect recoiling nuclei. In this paper we describe experimental concept present results on detection system, tested first time ArDM surface at CERN. With preliminary incomplete set PMTs, yield zero electric field found be between 0.3-0.5 phe/keVee depending position within...

10.1088/1748-0221/5/11/p11003 article EN Journal of Instrumentation 2010-11-22

The aim of the surgical treatment metatarsalgia is to decrease pressure under metatarsal (MT) head. Percutaneous surgery foot, also known as minimal invasive surgery, allows interventions be carried out through extremely small incisions without direct exposure field radiologic monitoring. current authors present their experience with distal MT osteotomy, in context indications, technique, postoperative management, and outcome. osteotomy has proven a valid providing satisfactory clinical...

10.1097/btf.0000000000000093 article EN Techniques in Foot & Ankle Surgery 2015-04-17

10.1016/s1888-4415(03)76145-1 article ES Revista Española de Cirugía Ortopédica y Traumatología 2003-01-01

The expression "learning curve" indicates the relation between time needed to learn a new technique and technique-related outcome. Percutaneous surgery (also called "minimally invasive surgery") has experienced sustained respectable growth, especially in forefoot deformities. main purpose was assess number of feet necessary become skilled specific minimally (MIS) procedure.

10.1177/19386400221079198 article EN Foot & Ankle Specialist 2022-03-03

S5363rd ESTRO Forum 2015 the low penetration of kV x-rays limits their useful depth range.An interesting solution is to bring x-ray tube close GNP-loaded tumors.But this can result in non-uniform tumor dose distributions.Although a sharp falloff brachytherapy, it may not be desirable for thick tumors.Here, DE was investigated with additional aim creating uniformity, idea being that using different concentrations GNP within potentially as means compensating falloff.Materials and Methods: A...

10.1016/s0167-8140(15)40992-2 article EN cc-by-nc-nd Radiotherapy and Oncology 2015-04-01
Coming Soon ...