Zili Wang

ORCID: 0000-0002-6125-849X
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Microgrid Control and Optimization
  • Islanding Detection in Power Systems
  • Fault Detection and Control Systems
  • HVDC Systems and Fault Protection
  • Power Systems and Renewable Energy
  • Power System Optimization and Stability
  • Fluid Dynamics and Heat Transfer
  • Optimal Power Flow Distribution
  • Reliability and Maintenance Optimization
  • Ultrasound and Cavitation Phenomena
  • Advanced Wireless Communication Techniques
  • Adaptive Control of Nonlinear Systems
  • Advanced DC-DC Converters
  • Wireless Communication Networks Research
  • Risk and Safety Analysis
  • Control Systems and Identification
  • Electric Vehicles and Infrastructure
  • Advanced Wireless Communication Technologies
  • Fluid Dynamics and Mixing
  • Advanced Battery Technologies Research
  • Technology Assessment and Management
  • Robotic Path Planning Algorithms
  • Advancements in Battery Materials
  • UAV Applications and Optimization
  • Software Reliability and Analysis Research

Beihang University
2010-2024

Hunan University
2008-2024

Hunan First Normal University
2024

Shandong Normal University
2023-2024

Shenzhen University
2024

Chongqing University of Science and Technology
2024

Jiangsu University of Science and Technology
2020-2023

Third Xiangya Hospital
2017-2022

Nanjing University of Aeronautics and Astronautics
2021-2022

Central South University
2017-2022

This article proposes an enhanced active disturbance rejection control (ADRC) method for the attitude deformation system of a self-developed mobile robot in conjunction with evolutionary game theory-based pigeon-inspired optimization (EGPIO). To achieve precise object, EGPIO is employed as automatic tuning mechanism ADRC, and simultaneously improves rapidity robustness controller. In this novel algorithm, individuals (PIO) adjust their strategies dynamically proceeds so to promote...

10.1109/tmech.2019.2953239 article EN IEEE/ASME Transactions on Mechatronics 2019-11-13

Similar to the traditional synchronous generator (SG), a drawback of virtual (VSG) is active power oscillation, especially in system with parallel VSGs. In this paper, decentralized transient damping (DTD) control strategy proposed suppress oscillation during load fluctuations VSGs system, which based on embedding electromagnetic compensation and (TDPCP) into original VSG controller, providing two new degrees freedom for flexible regulation ratio without frequency measurement. way, can be...

10.1109/tsg.2022.3233121 article EN IEEE Transactions on Smart Grid 2022-12-30

Droop control and inertia are the typical modes for energy storage system (ESS) suppressing power oscillations. However, when effect is enhanced to some certain extent, ESS will limit output device maximum (termed modulation mode) be out of expected because limited converter capacity. This paper focuses on evaluation index oscillation suppression compares ability rate change rotor speed with different modes. The study shows that oscillations can better suppressed than droop by providing fast...

10.1049/icp.2024.2287 article EN IET conference proceedings. 2025-01-01

In islanded microgrids with complex feeder networks, distributed generation units (DGs) and loads can be freely connected to any node, leading changes in the impedance between nodes microgrid structure. However, traditional harmonic sharing control methods encounter difficulties topologies. Additionally, existing techniques essentially require constructing additional virtual impedance, possibly resulting conflict voltage quality effectiveness. To address this issue, paper proposes an...

10.1109/tsg.2021.3112692 article EN IEEE Transactions on Smart Grid 2021-09-15

For the distributed generation units (DGs) using virtual synchronous generator (VSG) control algorithm connected to islanded microgrid with high penetration of nonlinear load, there is always a trade-off between harmonics sharing accuracy and voltage quality when conventional methods. To address this issue, an impedance-based adaptively reshaping method proposed in paper, which based on harmonic current feedforward compensation impedance factor adaptive control, assigning variable for each...

10.1109/tsg.2022.3159726 article EN IEEE Transactions on Smart Grid 2022-03-15

Uncertainty analyses have been considered critical analysis methods for identifying the risks in reliability evaluations. However, with multi-phase, multi-state, and repairable features, this method cannot effectively precisely display evaluation results uncertainty dynamic complex systems. In paper, has conducted of safety-related risk a nuclear power plant (NPP). A GO-FLOW Bayesian network (DBN) combination approach is proposed paper. Based on unified rules, various operators can be mapped...

10.1109/access.2017.2775743 article EN cc-by-nc-nd IEEE Access 2017-11-20

Layered two-dimensional ferromagnetic materials have emerged as a promising platform for spintronic applications, owing to their extraordinary physical properties. Remarkably, the representative ferromagnet Fe3GeTe2 has been extensively investigated due its high Curie temperature and strong perpendicular magnetic anisotropy, which are beneficial high-density storage at room temperature. However, there few reports on stability in air surface oxidation products, may prohibit future...

10.1063/5.0194520 article EN cc-by APL Materials 2024-03-01

The dynamics of a spark-generated bubble (a discharge short circuit) generated in proximity to stationary air attached plate is experimentally investigated by high-speed photography. Numerous interesting and complex interactions occur during the two coupling pulsation owing deformation properties or “free surface” characteristics supplied bubble. Complex jetting behaviors, such as splitting, jets away from plate, variable directional jets, multidirectional are observed. Passive observed...

10.1063/5.0009903 article EN Physics of Fluids 2020-06-01

Online state-of-charge (SOC) estimation for lithium-ion batteries is one of the most important tasks battery management system in ensuring its operation safety and reliability. Due to advantages learning long-term dependencies between sequential data, recurrent neural networks (RNNs) have been developed shown their superiority over SOC estimation. However, only time-series measurements (e.g., voltage current) are taken as inputs these RNNs. Considering that mapping relationship evolves along...

10.3390/ma15175933 article EN Materials 2022-08-27

Due to the dynamic interaction between inverter and grid, may have power oscillation problems under a weak grid. In this article, considering frequency coupling, more precise broadband sequence admittance model of current-controlled virtual synchronous generator (CVSG) is established, characteristics CVSG traditional grid-connected (TGCI) are compared analyzed. The amplitude generally larger than that TGCI in low-frequency region, entire sweep range, coupling TGCI. has great impact on...

10.1109/jestpe.2022.3213258 article EN IEEE Journal of Emerging and Selected Topics in Power Electronics 2022-10-10

Due to the high inherent uncertainty of renewable energy, probabilistic day-ahead wind power forecasting is crucial for modeling and controlling energy smart grids in cities. However, accuracy reliability high-resolution are constrained by unreliable local weather prediction incomplete generation data. This article proposes a physics-informed artificial intelligence (AI) surrogates method augment dataset quantify its improve performance. The dataset, built with numerical data, historical...

10.32604/cmes.2023.027124 article EN Computer Modeling in Engineering & Sciences 2023-01-01

Transient angle instability and fault overcurrent are two serious problems affecting the safe operation of virtual synchronous generator during grid faults. However, aspects mostly treated as independent in existing studies. In this article, taking both transient into consideration, a two-stage control collaboratively utilizing impedance (VI) switching PI is put forward. stage one, VI switched to boundary value determined by iteration algorithm avoid overcurrent. two, proportional loop or...

10.1109/tie.2023.3292877 article EN IEEE Transactions on Industrial Electronics 2023-08-04

Identifying effective plasmonic photocatalysts exhibiting robust activities across the entire solar spectrum poses a significant challenge. CuSe, with its local surface plasmon resonance (LSPR) effect, has garnered attention as prospective photocatalyst. However, severe charge recombination and insufficient light absorption limit photocatalytic performance. To enhance performance, constructing CuSe-based n-p semiconductor heterostructures is potential strategy. MXene quantum dots (MQDs),...

10.1021/acs.langmuir.4c03170 article EN Langmuir 2024-11-11

This paper proposes a signal timing scheme through two-stage fuzzy logic controller. The controller first determines the phase and then adjusts green time. At stage, adaptive membership function of vehicle arrival rate is improved to adapt changing traffic flow. In addition queue vehicles, specific order rule considered avoid disordered selection in control. second time detection module decides whether extend current or switch phases every few seconds not required as input real-time...

10.1155/2021/6693562 article EN cc-by Mathematical Problems in Engineering 2021-03-12

Self-synchronizing voltage source inverter (SSVSI) can effectively improve grid frequency stability. However, the synchronous resonance (SFR) inevitably exists in SSVSI. In this paper, a small-signal model considering power coupling is established to analyze system characteristics. It found that control parameter adjustment and virtual resistance method suppress SFR. will change dynamic steady-state characteristics of system, exacerbate system. For reason, based on idea eliminating peaks,...

10.1016/j.ijepes.2024.109981 article EN cc-by-nc-nd International Journal of Electrical Power & Energy Systems 2024-04-15

In this paper, a seamless transfer control strategy for three-phase inverter in microgrid is proposed to reduce the impact of grid-injection current during grid-tied transient period, and restrain dc side voltage fluctuation islanding period. To improve response, soft-start virtual impedance single loop feedback between mode seamlessly. During weighted average phase advance reference output presented introduce into power droop loop, also introduced order current. Otherwise, while cuts off...

10.1109/ipemc.2016.7512560 article EN 2016-05-01
Coming Soon ...