Bingqing Sun

ORCID: 0000-0002-6400-7979
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Corneal surgery and disorders
  • Corneal Surgery and Treatments
  • Ophthalmology and Visual Impairment Studies
  • Glaucoma and retinal disorders
  • Ocular Surface and Contact Lens
  • Tissue Engineering and Regenerative Medicine
  • Retinal Diseases and Treatments
  • Ocular Diseases and Behçet’s Syndrome
  • Ocular Disorders and Treatments
  • Advanced Optical Imaging Technologies

Eye & ENT Hospital of Fudan University
2022-2025

Chinese Academy of Medical Sciences & Peking Union Medical College
2023-2025

Shanghai Clinical Research Center
2023-2025

Shanghai Eye Disease Prevention & Treatment Center
2023-2025

Fudan University
2023-2024

Shanghai Jiao Tong University
2023

Shanghai First People's Hospital
2023

Creative Commons
2023

National Natural Science Foundation of China
2023

Shanghai Municipal Commission of Health and Family Planning
2023

To investigate the long-term safety and efficacy of using keratorefractive lenticule extraction (KLEx)-derived corneal stromal lenticules preserved in nutrient capsules for treatment diseases. Eye ENT Hospital Fudan University. Observational study. Ten eyes 10 patients with diseases (6 males, 4 females, age 38.10 ± 9.11 years, ) were treated phototherapeutic keratectomy combined epikeratophakia or intrastromal keratoplasty KLEx-derived lenticules. Corneal which used transplantation was...

10.1186/s12886-025-03891-6 article EN cc-by-nc-nd BMC Ophthalmology 2025-02-10

Abstract The corneal lenticules extracted from small incision lenticule extraction (SMILE) can be used as an optional transplantation material. However, it cannot for deep anterior lamellar keratoplasty due to its thickness limitations. In this study, oxidized chondroitin sulfate (O─CS) containing ─SO 3 − groups twisted with generation 4.0 polyamidoamine dendrimers (G4 PAMAM) which contain −NH 2 + via electrostatic entanglement form a cohesive module, is applicable in suture‐free of cornea,...

10.1002/adfm.202423392 article EN Advanced Functional Materials 2025-03-17

The purpose of this study was to investigate the ex vivo and in biomechanical characteristic cornea myopic eyes.

10.1167/iovs.64.10.27 article EN cc-by-nc-nd Investigative Ophthalmology & Visual Science 2023-07-21

Abstract Background This study assessed the agreement of ocular parameters patients with myopia measured using Colombo intraocular lens (IOL) 2 and IOLMaster 700. Methods Eighty (male, 22; average age, 29.14 ± 7.36 years) (159 eyes) were included in this May 2023. The participants’ axial length (AXL), central corneal thickness (CCT), (LT), white-to-white distance (WTW), front flat (K1), steep (K2), mean (Km) keratometry, astigmatism (Astig), J0 vector, J45 vector 700 IOL 2. measurements from...

10.1186/s12886-024-03546-y article EN cc-by BMC Ophthalmology 2024-07-16

This study aimed to investigate the underlying pathophysiology of high myopia by analyzing proteome human corneal stromal lenticule samples obtained through small incision extraction (SMILE). A total thirty-two patients who underwent SMILE were included in study. Label-free quantitative proteomic analysis was performed on samples, equally representing (n = 10) and low groups. The identified profiled proteomes analyzed using silico tools explore biological characteristics differentially...

10.1016/j.exer.2023.109726 article EN cc-by-nc Experimental Eye Research 2023-11-17

Purpose: To evaluate changes of hydroxyproline concentration and its influencing factors small incision lenticule extraction (SMILE)-derived corneal stromal lenticules with different preservation methods. Methods: A total 390 195 patients were derived from SMILE surgeries. Thirty the classified as fresh (control) group, rest randomly evenly divided stored in anhydrous glycerol, silicone oil, Optisol, cryopreservation for 1 day, week, or month. assay kit (ab222941, Abcam) was used to measure...

10.1097/ico.0000000000003615 article EN Cornea 2024-07-05

To compare the characteristics of corneal thickness measurements among RTVue, Casia-2, and Pentacam in patients with mild-to-moderate keratoconus.We recruited 46 eyes diagnosed keratoconus at our hospital between January March 2022. The central (CCT) thinnest (TCT) were measured using two optical coherence tomography (OCT) instruments (RTVue Casia-2) more conventional Pentacam. Differences correlations CCTs TCTs, based on device influencing factors, explored.The highly consistent groups (p =...

10.1186/s12886-023-02767-x article EN cc-by BMC Ophthalmology 2023-01-26

<title>Abstract</title> Background This study assessed the agreement of anterior segment parameters patients with myopia measured using 2 swept-source optical coherent biometry devices: Colombo intraocular lens (IOL) and IOL Master 700. Methods Eighty (male/female, 22/58; average age, 29.11 ± 7.77 years) (159 eyes) were included in this May 2023. All participants underwent measurements 700 to obtain axial length (AXL), central corneal thickness (CCT), (LT), white-to-white (WTW), front flat...

10.21203/rs.3.rs-4260335/v1 preprint EN cc-by Research Square (Research Square) 2024-04-24

Abstract Purpose Autostereoscopic displays have become increasingly common, but their impact on ocular dimensions remains unknown. We sought to identify changes in the crystalline lens induced by autostereoscopic three‐dimensional (3D) viewing. Methods Forty young adults (age: 22.6 ± 2.0 years, male/female: 15/25) were consecutively enrolled and randomly divided into two groups (3D two‐dimensional [2D] viewing groups) watch a 30‐min movie clip displayed 3D or 2D mode tablet computer. The...

10.1111/opo.13361 article EN Ophthalmic and Physiological Optics 2024-07-09

Phototherapeutic keratectomy (PTK) combined with epikeratophakia (EP) using double lenticules through small-incision lenticule extraction (SMILE) after late recurrence was used in a patient Reis-Bückler corneal dystrophy (RBCD) who underwent bilateral PTK 9.5 years previously. Opacity recurred at 4 years, + EP being performed SMILE-derived lenticules, and 5.5 an uncorrected visual acuity of 20/100 disrupted counting fingers the right left eyes. eye on original were performed. Manifest...

10.1097/j.jcro.0000000000000104 article EN Journal of Cataract and Refractive Surgery Online Case Reports 2023-09-14

Abstract Purpose To analyze the corneal morphology of keratoconus using CASIA2, Sirius, and Pentacam. Methods Patients diagnosed with at Eye ENT Hospital Fudan University (January-November 2022) were included. Corneal refraction, astigmatism, thickness, elevation parameters measured The measurement differences, agreement, sensitivity specificity each instrument for diagnosing was evaluated. P &lt; 0.05 considered statistically significant. Results A total 61 eyes 48 healthy myopic Ks Kf...

10.21203/rs.3.rs-3219117/v1 preprint EN cc-by Research Square (Research Square) 2023-09-21

Abstract This study aimed to investigate the awareness of high and pathological myopia among patients with myopia. A cross‐sectional multicenter survey involving both physicians was conducted between February April 2021. The outpatient education status, doctors' expectations toward patient education, patients' high/pathological myopia, their access relevant knowledge were inquired, proportions including assessed. In total, involved 6975 from 161 medical institutions in China. prevalence...

10.1002/mef2.64 article EN cc-by MedComm – Future Medicine 2023-11-04

To investigate the relationship between corneal tomographic or biomechanical parameters and risk of keratoconus in very asymmetric ectasia (VAE).This retrospective case-control single-centre study included patients with VAE normal controls. The group had clinical one eye topography (VAE-NT) fellow eye; VAE-NT eyes were selected for analysis. control was from refractive surgery candidates; right enrolled. Scheimpflug-based tomography (Pentacam) assessment (Corvis ST) performed. Univariate...

10.2147/opth.s439739 article EN cc-by-nc Clinical ophthalmology 2023-11-01

Abstract Purpose To explore the characteristics of RTVue, Casia-2, and Pentacam instruments for measuring corneal thickness in patients with mild to moderate keratoconus. Methods We recruited diagnosed keratoconus at our hospital from January March 2022; 46 eyes (46 patients) were enrolled (35 men [76.09%], 30 right [65.22%], mean age 24.3 ± 6.2 years). Central (CCT) thinnest (TCT) measured using two optical coherence tomography (OCT) (RTVue Casia-2) more conventional Pentacam. Then,...

10.21203/rs.3.rs-1980004/v1 preprint EN cc-by Research Square (Research Square) 2022-08-31
Coming Soon ...