- Bone Tissue Engineering Materials
- Titanium Alloys Microstructure and Properties
- Additive Manufacturing Materials and Processes
- Antenna Design and Analysis
- Magnesium Alloys: Properties and Applications
- Additive Manufacturing and 3D Printing Technologies
- Orthopaedic implants and arthroplasty
- Hydrogen Storage and Materials
- Dental materials and restorations
- Antenna Design and Optimization
- Finite Group Theory Research
- High Entropy Alloys Studies
- Advanced Antenna and Metasurface Technologies
- Laser Material Processing Techniques
- Welding Techniques and Residual Stresses
- Minerals Flotation and Separation Techniques
- Advanced Topics in Algebra
- 3D Printing in Biomedical Research
- Limits and Structures in Graph Theory
- Microwave Engineering and Waveguides
- Advanced DC-DC Converters
- Structural Analysis and Optimization
- Cellular and Composite Structures
- Laser-Ablation Synthesis of Nanoparticles
- Geophysical Methods and Applications
Southern University of Science and Technology
2020-2025
Changzhou University
2025
Southwest University of Science and Technology
2023-2024
Beijing University of Chinese Medicine
2024
Jiaxing University
2023
Chinese Academy of Sciences
2022
Hunan University
2018
Although numerous reports have elucidated the neurotoxic impacts of Ti-6Al-4V (Ti64) due to presence vanadium, it is most widely used biomedical Ti material. This because exhibits significantly better mechanical performance characteristics than those pure Ti. In addition possibility facilitating production customized medicines, selective laser melting (SLM) additive manufacturing (AM) can enable match properties Ti64 by utilizing several mechanisms such as grain refinement and solid solution...
ABSTRACT In a cascaded converter, an LC filter is usually added to the front of load converter attenuate current ripple fed forward source converter. When parameters are improperly selected, feedforward (FCR) can induce fast‐scale instability in However, circuit order introduced by and its input increases modeling complexity To simplify complexity, fundamental harmonic‐based equivalent method proposed for FCR. A peak‐current‐mode controlled buck with open‐loop considered. An model...
Ti and alloys are being widely used as bone tissue repair materials. Progress on mechanical properties bio-functionality is required for their applications due to the large difference in elastic modulus between implants fact that materials themselves biologically inert. In this work, a low-modulus, β-phase Ti-15Mo alloy based triply periodical minimal surfaces (TPMS) structure was fabricated using Powder Bed Fusion-Laser Beam (PBF-LB) under optimized printing parameters into implant samples...
Magnesium alloys such as Mg–Ca and Mg–Zn–Ca are good orthopaedic materials; however their tendency to corrode is high. Herein we utilize selective laser melting (SLM) modify the surface of these Mg simultaneously improve corrosion behaviour microhardness. The rate decreased from 2.1 ± 0.2 mm/y 1.0 0.1 for laser-processed Mg–0.6Ca, 1.6 0.7 Mg–0.5Zn–0.3Ca. microhardness increased 46 1 HV 56 47 3 55 In addition, biocompatibility remained in processed alloys. improved properties attributed...
To clarify the antibacterial behavior at early adhesion, two titania nanotube (TNT) arrays were fabricated on polished commercially pure titanium (Ti), and interaction mechanisms between TNT model bacteria (Escherichia coli, E. coli) investigated. The results show that exhibit a significant effect, which is highly related to surface free energy nano-topography. underlying include: (1) anti-initial-attachment effect lag phase (0−4 h); (2) anti-proliferation physical bactericidal effects...
Residual powder is a defect in bed fusion-based additive manufacturing (3D printing), and it difficult to completely remove from as-printed materials. In addition, not necessary apply 3D printed implants with residual the clinic. The immunological response triggered by an important area of study medical research. To further understand possible reactions hidden dangers caused powders vivo, this compared osteolysis typical for four implant materials: 316 L stainless steel, CoCrMo, CP-Ti,...
The influence of heterogeneous microstructures on the anodization behavior and biocompatibility Ti-based alloys was investigated. A Ti−15Zr alloy fabricated by powder metallurgy, followed hot rolling heat treatments. Electrochemical then applied to obtaining a nanotube-arrayed surface. results show that surface anodized consists nano-sized tube structure as well micron-scaled tubular clusters microcracks. formation such should be attributed (0001)-oriented striped grains Zr distribution....
Rhei Radix et Rhizoma is common traditional Chinese medicine with multiple original plants. The content and proportion of the active components in from different plant species were compared to accurately evaluate qua-lity provide a theoretical basis for precise use this clinical practice. In study, fresh samples collected four-year-old plants Rheum palmatum, R. tanguticum, officinale. relative 220 anthraquinones, anthrones, tannins determined by pseudo-targeted metabolomics, differential...