A. Todd

ORCID: 0000-0003-3525-1478
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Particle Accelerators and Free-Electron Lasers
  • Particle accelerators and beam dynamics
  • Gyrotron and Vacuum Electronics Research
  • Superconducting Materials and Applications
  • Nuclear Physics and Applications
  • Photocathodes and Microchannel Plates
  • Electron and X-Ray Spectroscopy Techniques
  • Advancements in Photolithography Techniques
  • Laser Design and Applications
  • Hyperglycemia and glycemic control in critically ill and hospitalized patients
  • Photonic and Optical Devices
  • Obstructive Sleep Apnea Research
  • Lightning and Electromagnetic Phenomena
  • Medical Imaging and Analysis
  • Head and Neck Cancer Studies
  • Cardiac, Anesthesia and Surgical Outcomes
  • Sleep and related disorders
  • Diabetes Management and Research
  • Cervical and Thoracic Myelopathy
  • Muon and positron interactions and applications
  • Magnetic Field Sensors Techniques
  • Hepatocellular Carcinoma Treatment and Prognosis
  • Neuroscience of respiration and sleep
  • Intravenous Infusion Technology and Safety
  • Advanced Electrical Measurement Techniques

Uniformed Services University of the Health Sciences
2014-2020

University of South Florida
2018

Brookhaven National Laboratory
1999-2007

Stony Brook University
2007

Advanced Energy Systems (United States)
2002-2006

Northrop Grumman (United States)
1994-2002

10.1016/j.nima.2005.10.087 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2005-11-22

ABSTRACT Introduction Hyperglycemia during the perioperative period has generally been accepted as a contributor of poor outcomes in patients with diabetes mellitus undergoing surgery. Although an optimal glycemic range not clearly established literature, consensus among national medical organizations recommends serum glucose levels to be maintained less than 180 mg/dL period. Materials and Methods The primary purpose this evidence-based project was identify blood values obtained from adult...

10.1093/milmed/usaa467 article EN Military Medicine 2020-11-16

We report progress on the R&D program for electron-cooling of Relativistic Heavy Ion Collider (RHIC). This electron cooler is designed to cool 100 GeV/nucleon at storage energy using 54 MeV electrons. The source will be a superconducting RF photocathode gun. accelerator recovery linac. frequency set 703.75 MHz. maximum bunch 9.38 MHz, with charge 20 nC. has following components: photoinjector and its photocathode, linac cavity, start-to-end beam dynamics magnetized electrons, cooling...

10.1109/pac.2005.1591249 article EN Proceedings of the 2003 Particle Accelerator Conference 2006-02-15

We present the design and parameters of an energy recovery linac (ERL) facility, which is under construction in Collider-Accelerator Department at BNL. This R&D facility has goal demonstrating CW operation ERL with average beam current range 0.1 - 1 ampere very high efficiency recovery. The possibility a future upgrade to two-pass also being considered. heart 5-cell 703.75 MHz super-conducting RF strong Higher Order Mode (HOM) damping. flexible lattice provides test-bed for exploring issues...

10.1109/pac.2005.1591070 article EN Proceedings of the 2003 Particle Accelerator Conference 2006-02-15

The physics interest in a luminosity upgrade of RHIC requires the development cooling-frontier facility. Detailed calculations were made electron cooling stored beams. This has been followed by beam dynamics simulations to establish feasibility creating necessary beam. accelerator will be superconducting Energy Recovery Linac (ERL). An intensive experimental R&D program engages various elements accelerator, as described 24 contributions 2007 PAC.

10.1109/pac.2007.4441143 article EN 2007-01-01

A transmission-type wattmeter can be formed utilizing the Hall effect to give wide-range multiplication over a frequency range extending from low audio-frequency region SHF band. At frequencies, device take form of thin wafer indium antimonide mounted in series with center leg cup core magnetic circuit. An employing such structure has been analyzed, constructed and tested. The zero 400 milliwatts when used 600-ohm circuit, displays error less than plus minus 3.5 per cent 100 6000 cps for...

10.1109/tau.1961.1166294 article EN IRE Transactions on Audio 1961-01-01

The Rapid Cycling Medical Synchrotron (RCMS) is a second generation synchrotron. transverse beam size dominated by multiple scattering, if the incoming at 1 mm level. It takes 10 overlapping pulses 0.5 cm wide to scan tumor 5 with % flatness. Small sizes are critical for inexpensive gantries, since small beams permit use of small, lightweight, magnets which economical operate. RCMS achieves applying "strong focusing" optics emittance beam. Gantries and nozzles, control systems design discussed.

10.1109/pac.2001.987804 article EN PACS2001. Proceedings of the 2001 Particle Accelerator Conference (Cat. No.01CH37268) 2002-11-14

Anterior cervical discectomy and fusion (ACDF) is a common procedure with more than 137,000 cases in the United States (U.S.) each year. Historically, ACDF has been relatively safe despite encountering vital anatomical structures that can risk serious complications. One particularly dangerous sequela of lacerating vertebral artery (VA). While VA injuries are rare (0.5% cases), it crucial for surgeons to prevent this potentially deadly complication thorough knowledge anatomy. The commonly...

10.13107/jocr.2024.v14.i08.4674 article EN cc-by-nc Journal of Orthopaedic Case Reports 2024-01-01

A key technology issue on the path to high-power FEL operation is demonstration of reliable, high-brightness, injector operation. We describe two ongoing programs produce 100 mA injectors as drivers for kW free-electron lasers. In one approach, in collaboration with Thomas Jefferson National Accelerator Facility, we are fabricating a 750 MHz superconducting RF cryomodule that will be integrated room-temperature DC photocathode gun and tested at Laboratory. other Los Alamos Laboratory,...

10.1109/pac.2003.1289575 article EN 2004-07-08

In this paper we present status and plans for the 20- MeV R&D energy recovery linac (ERL), which is under construction at Collider Accelerator Department BNL. The facility based on high current (up to 0.5 A of average current) super-conducting 2.5 RF gun,single-mode 5-cell about 20-m long return loop with very flexible lattice. ERL, planned commissioning in early 2009, aims address many outstanding questions relevant current, brightness energy-recovery linacs.

10.1109/pac.2007.4441078 article EN 2007-01-01

The design of the Continuous Wave Deuterium Demonstrator (CWDD) and status fabricated hardware is presented. CWDD a high brightness, 352 MHz, CW linear accelerator designed to deliver 7.54 MeV, 80 mA D/sup -/ beam at transverse normalized rms emittance 0.11 /spl pi/ mm-mrad longitudinal 0.20 mm-mrad. End-to-end dynamics analysis for nominal off-design conditions described. tuning predicted operational performance as-built device are also discussed. These results all indicate that present can...

10.1109/pac.1993.309129 article EN 2002-12-30

The Maryland Infrared Free Electron Laser is being constructed at the University of Maryland, and expected to lase in far infrared. accelerator driving laser a 10 MeV linac which assembled an "in-line" configuration. design work for was accomplished using Trace-3D PARMELA computer simulations. When completed, it will be able accommodate several additional experimental sections within beam line itself order further study physics.

10.1109/pac.2001.987900 article EN PACS2001. Proceedings of the 2001 Particle Accelerator Conference (Cat. No.01CH37268) 2002-11-14
Coming Soon ...