Yun‐e Zhao

ORCID: 0000-0003-4401-8053
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Intraocular Surgery and Lenses
  • Corneal surgery and disorders
  • Glaucoma and retinal disorders
  • Ophthalmology and Visual Impairment Studies
  • Ocular Surface and Contact Lens
  • Connexins and lens biology
  • Corneal Surgery and Treatments
  • Retinal and Macular Surgery
  • Ocular Infections and Treatments
  • Retinal Diseases and Treatments
  • Ophthalmology and Eye Disorders
  • Ocular Diseases and Behçet’s Syndrome
  • Ocular Disorders and Treatments
  • Optical Coherence Tomography Applications
  • Ureteral procedures and complications
  • Traumatic Ocular and Foreign Body Injuries
  • Visual perception and processing mechanisms
  • Retinal Development and Disorders
  • Retinal Imaging and Analysis
  • Cerebral Venous Sinus Thrombosis
  • Cardiovascular Conditions and Treatments
  • Advanced Glycation End Products research
  • Retinopathy of Prematurity Studies
  • Cardiovascular Issues in Pregnancy
  • Neural dynamics and brain function

Wenzhou Medical University
2016-2025

Affiliated Eye Hospital of Wenzhou Medical College
2016-2025

National Clinical Research Center for Digestive Diseases
2021-2025

National Clinical Research
2025

State Key Laboratory of Ophthalmology
2024

Zhaotong University
2023

Second Affiliated Hospital of Nanjing Medical University
2023

Ministry of Education of the People's Republic of China
2016-2022

Creative Commons
2021

Wenzhou Municipal Sci-Tech Bureau
2020

PURPOSE: To compare axial length measurements (and failure rate) of three swept-source optical coherence tomography (SS-OCT)–based biometers: IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany), OA-2000 (Tomey, Nagoya, Japan), and Argos (Movu Inc., Komaki, Japan) to those provided by a partial interferometry (PCI)–based biometer (IOLMaster v5.4 [Carl Meditec]). METHODS: A total 119 patients (171 eyes) undergoing cataract surgery were enrolled. Axial was measured with the four biometers in...

10.3928/1081597x-20190109-01 article EN cc-by-nc Journal of Refractive Surgery 2019-02-01

For patients who experience dry eye after phacoemulsification, vision and quality of life can significantly deteriorate. In this study, the efficacy safety carboxymethylcellulose sodium (CMC) 1% ophthalmic solution combined with conventional therapy in treating signs symptoms phacoemulsification were evaluated.In prospective, multicenter, open-label, controlled 180 age-related cataract randomized to treatment plus CMC (n = 90) or only (control group, n intraocular lens implantation. Tear...

10.1186/s12886-015-0005-3 article EN cc-by BMC Ophthalmology 2015-03-19

Purpose . To investigate meibomian gland and tear film function in patients with type 2 diabetes. Methods This prospective study compared changes diabetic nondiabetic patients. Meibomian was evaluated by measuring lipid layer thickness (LLT), grading of loss, lid margin abnormalities, expression meibum. Tear assessed breakup time (TBUT), the Schirmer I test, noninvasive (NIBUT), meniscus height (TMH), corneal fluorescein staining. Results Meibography scores were significantly higher group...

10.1155/2017/3047867 article EN cc-by Journal of Ophthalmology 2017-01-01

PURPOSE: To compare the accuracy of Barrett Universal II, Emmetropia Verifying Optical (EVO), Haigis, Kane, and SRK/T formulas for intraocular lens power calculation in patients with high axial myopia. METHODS: In this retrospective study, 175 eyes (175 patients) that underwent uneventful cataract surgery were enrolled. According to length (AL), divided into long AL (26 ⩽ < 28 mm), super (28 30 extremely (⩾ mm). The mean absolute prediction errors (MAE) 3 months postoperatively percentage...

10.3928/1081597x-20210712-08 article EN Journal of Refractive Surgery 2021-11-01

Abstract Cataract is the first leading cause of blindness in world and posterior capsule opacification (PCO) most common long‐term complication after surgery. The primary pathogenic processes contributing to PCO are proliferation migration residual lens epithelial cells (LECs). This study aimed explore mild photothermal effect on LECs. Interestingly, this work finds that significantly inhibited live cell fluorescence imaging reveals remodeling actin cytoskeleton morphology attributed...

10.1002/adhm.202300470 article EN Advanced Healthcare Materials 2023-09-20

The aim of this work is to evaluate the accuracy Barrett Universal II (BU II), Emmetropia verifying optical (EVO) 2.0, Haigis, Hoffer Q, QST (Savini/Taroni) (HQST), Holladay 1, Kane, Ladas Super, Sanders–Retzlaff–Kraff/theoretical (SRK/T), and T2 intraocular lens (IOL) power formulas for calculating spherical equivalent (SE) toric IOL. This study enrolled consecutive patients who underwent phacoemulsification IOL implantation at Eye Hospital Wenzhou Medical University in Hangzhou from 2015...

10.1007/s40123-024-00926-x article EN cc-by-nc Ophthalmology and Therapy 2024-03-20

To study the effect of incision size on optical quality anterior cornea by comparing changes in corneal wavefront aberrations between microincision cataract surgery (MICS) and small-incision (SICS).Eye Hospital Wenzhou Medical College, Wenzhou, Zhejiang, China.This prospective randomized clinical included 36 eyes having MICS (1.5 mm) 38 SICS (3.0 mm). Anterior topography was measured preoperatively 3 to 6 months postoperatively. The data were used calculate Zernike (through 6th order) for a...

10.1016/j.jcrs.2008.08.020 article EN Journal of Cataract & Refractive Surgery 2008-11-22

Introduction: Cataract surgery has been reported to have a reducing effect on intraocular pressure (IOP) in glaucomatous and non-glaucomatous eyes. This seems be more noticeable eyes with narrow angles (NAs) than open (OAs). Decrease IOP may result of the increase anterior chamber angle (ACA) Schlemm canal (SC) after cataract surgery. The purpose this paper is evaluate relationship between canal-cross-sectional area (SC-CSA) changes trabecular meshwork, ciliary muscle difference angles....

10.1159/000543303 article EN cc-by-nc Ophthalmic Research 2025-01-21

To evaluate the changes in meibomian gland function, ocular surface parameters, and optical quality before after expression patients with dysfunction (MGD). Patients MGD underwent once weekly for 4 consecutive weeks. Comprehensive assessments, including Ocular Surface Disease Index questionnaire, tear break-up time, corneal fluorescein staining, lid margin abnormality grading, meibum expressibility evaluations, Schirmer I test (SIT), as well examinations using Pentacam Optical Quality...

10.1080/02713683.2025.2497324 article EN Current Eye Research 2025-04-28

Purpose: To evaluate the safety and stability of an intraocular lens(IOL) made crosslinked polyisobutylene (xPIB), a novel biomaterial for new-generation foldable IOL. Setting: Eye Hospital Wenzhou Medical University, Hangzhou, Zhejiang Province, China. Design: Prospective observational study. Methods: This was prospective, parallel-controlled, randomised clinical Participants were randomly enrolled in 1:1 ratio underwent one-eye cataract removal with either xPIB or Acrysof (control) IOL...

10.1097/j.jcrs.0000000000001685 article EN Journal of Cataract & Refractive Surgery 2025-05-14

Purpose To quantitate lens nuclear opacity using long-range swept-source optical coherence tomography (SS-OCT) images and to evaluate the correlation of this method Lens Opacities Classification System III (LOCS III) a Scheimpflug imaging-based grading system (Pentacam Nuclear Stage function; PNS). Methods This study enrolled 120 participants (120 eyes) with age-related cataracts. The best-corrected visual acuity (BCVA), LOCS opalescence (NO) colour (NC) were obtained. density measured PNS...

10.1136/bjophthalmol-2018-312661 article EN British Journal of Ophthalmology 2018-10-12

PURPOSE: To systematically compare the efficacy, predictability, safety, postoperative haze, pain scores, and epithelial healing time of four corneal surface ablation procedures. METHODS: PubMed, Embase, Cochrane Library, U.S. trial registry were searched up to June 2018. Randomized controlled trials selected. Efficacy (uncorrected distance visual acuity 20/20 or better), predictability (refractive spherical equivalent within ±0.50 diopters [D] target), safety (loss two more lines spectacle...

10.3928/1081597x-20180905-01 article EN cc-by-nc Journal of Refractive Surgery 2018-11-01

Purpose . To evaluate the effect of anterior capsule polishing in patients with high myopia after cataract surgery. Setting The Eye Hospital Wenzhou Medical University, Zhejiang, China. Design Prospective study. Methods High myopic a bilateral who underwent phacoemulsification 360° capsular one eye and without contralateral were recruited. following parameters recorded at 1, 3, 6 months postoperatively, including area diameter opening (area D), IOL tilt decentration, refraction,...

10.1155/2018/8676451 article EN cc-by Journal of Ophthalmology 2018-10-23

Abstract Background To evaluate the correlations between lipid layer thickness (LLT) and morphology function of meibomian glands in patients who were diagnosed as gland dysfunction (MGD) different age groups. Methods Patients have obstructive MGD included this prospective, cross-sectional study. divided into three groups: young (ages 20–39 years), middle-aged 40–59 older (aged ≥60 years). All completed an Ocular Surface Disease Index (OSDI) questionnaire evaluated for LLT, tear meniscus...

10.1186/s12886-020-01667-8 article EN cc-by BMC Ophthalmology 2020-10-06

To investigate the effect of corneal curvature (K) on accuracy 8 intraocular lens formulas in highly myopic eyes.Eye Hospital and School Ophthalmology Optometry, Wenzhou Medical University, Wenzhou, China.Retrospective consecutive case series.302 eyes (302 patients) were analyzed subgroups based K value. The mean refractive error, absolute error (MAE), median (MedAE), root-mean-square prediction (RMSAE) proportions within ±0.25 diopter (D), ±0.50 D, ±0.75 ±1.00 D statistical...

10.1097/j.jcrs.0000000000001303 article EN Journal of Cataract & Refractive Surgery 2023-09-13

ABSTRACT We developed a stable, high‐penetration arm‐type swept‐source optical coherence tomography (SS‐OCT) system for visualizing retinal and choroidal structures in pediatric patients with congenital cataracts. The features compact OCT probe an integrated iris camera fixation target easy alignment, mounted on five‐degree‐of‐freedom adjustable arm to reduce motion artifacts operator fatigue. Feasibility was demonstrated through supine imaging of healthy adults, cataract children, infants,...

10.1002/jbio.70039 article EN Journal of Biophotonics 2025-04-24

PurposeThickness changes of corneal sub-layers after phacoemulsification were investigated by spectral domain ultra-high resolution optical coherence tomography (UHR-OCT). MethodsThe corneas (n = 26) 26 age-related cataract surgery patients studied. UHR-OCT was used to evaluate the thickness Descemet's Endothelium Complex (DEC), stroma, Bowman's layer, epithelium, and full cornea at center (CCT) before, one day after, week surgery. Non-contact specular microscopy measured CCT, endothelial...

10.1371/journal.pone.0080986 article EN cc-by PLoS ONE 2013-11-28
Coming Soon ...