Jianxin Sun

ORCID: 0009-0007-0003-3821
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Orthopedic Surgery and Rehabilitation
  • Computer Graphics and Visualization Techniques
  • Silicon and Solar Cell Technologies
  • Reconstructive Surgery and Microvascular Techniques
  • Semiconductor materials and interfaces
  • Multimodal Machine Learning Applications
  • Bone fractures and treatments
  • Data Visualization and Analytics
  • 3D Shape Modeling and Analysis
  • Nerve Injury and Rehabilitation
  • Advanced Vision and Imaging
  • Medical Malpractice and Liability Issues
  • Peripheral Nerve Disorders
  • Traditional Chinese Medicine Analysis
  • Gas Sensing Nanomaterials and Sensors
  • Human Pose and Action Recognition
  • Constraint Satisfaction and Optimization
  • Cognitive Computing and Networks
  • Ginseng Biological Effects and Applications
  • Analytical Chemistry and Sensors
  • Video Surveillance and Tracking Methods
  • Congenital limb and hand anomalies
  • Face recognition and analysis
  • Advanced Data Compression Techniques
  • Metabolomics and Mass Spectrometry Studies

Yancheng Institute of Technology
2022-2024

University of Nebraska–Lincoln
2011-2024

Institute of Automation
2024

Qilu Hospital of Shandong University
2024

National Institute of Advanced Industrial Science and Technology
2017

Korea Research Institute of Standards and Science
2017

Qinhuangdao Second Hospital
2011-2017

Second Hospital of Tangshan
2012

Third Hospital of Hebei Medical University
2011-2012

Hebei Medical University
2011-2012

Visualizing a large-scale volumetric dataset with high resolution is challenging due to the computational time and space complexity. Recent deep-learning-based image inpainting methods significantly improve rendering latency by reconstructing high-resolution for visualization in constant on GPU from partially rendered where only small portion of pixels go through expensive pipeline. However, existing need render every pixel predefined regular sampling pattern. In this work, we provide...

10.48550/arxiv.2502.06053 preprint EN arXiv (Cornell University) 2025-02-09

The purpose of this study was to introduce a new surgical technique carpal tunnel release through double small incisions, and compare the with standard open endoscopic release.Two hundred seven patients were allocated randomly into group A (n = 73), B 65), or C 69). Patients in treated by means incisions. incision. had release.Preoperatively, mean severity symptoms groups A, B, 3.7 ± 0.58, 3.8 0.62, 0.52, respectively; functional status 3.2 0.71, 3.5 0.64, respectively. At final follow-up 3...

10.1097/prs.0000000000002511 article EN Plastic & Reconstructive Surgery 2016-05-12

Text-driven person image generation is an emerging and challenging task in cross-modality generation. Controllable promotes a wide range of applications such as digital human interaction virtual try-on. However, previous methods mostly employ single-modality information the prior condition (e.g. pose-guided generation), or utilize preset words for text-driven synthesis. Introducing sentence composed free with editable semantic pose map to describe appearance more user-friendly way. In this...

10.48550/arxiv.2211.06235 preprint EN cc-by arXiv (Cornell University) 2022-01-01

The aim of this study was to introduce and evaluate the functional results volar plating distal radial fractures through a longitudinal minimally invasive approach.From January 2010 2013, 157 patients with were randomly allocated group A (n = 83; 49 men, 34 women; mean age: 42 (18-67)) B 74; 46 28 41 (22-65)), including type A2, A3, B3, C1, C2 fractures, based on AO Foundation Orthopaedic Trauma Association Classification. Patients in treated 1.5- 2-cm incision, conventional flexor carpi...

10.1016/j.aott.2017.02.013 article EN cc-by-nc-nd Acta Orthopaedica et Traumatologica Turcica 2017-02-28

In the present study, we establish a physical model for laser-assisted localized boron doping in N-type tunnel oxide passivated contact (TOPCon) solar cells by employing fluid dynamics method. Our simulations reveal that flat-top beam inflicts less thermal damage on silicon than Gaussian at constant laser energy density. Additionally, observe an acceleration flow rate of molten pool as density increases. This facilitates efficient atoms into substrate, albeit accompanied expansion local...

10.1109/jphotov.2024.3380461 article EN IEEE Journal of Photovoltaics 2024-04-15

This article introduces the use of a modified reverse dorsal hand flap harvested from radial portion and wrist distal forearm for reconstruction large defect involving third to fifth metacarpophalangeal (MCP) joints proximal phalanges. From May 2005 August 2008, was transferred in 12 hands patients (9 male 3 female). The mean age at transfer 34.2 years (range: 23 50 years) old. All flaps survived. At final follow-up (mean, 28 months; range: 25 32 months), active range motion arcs third,...

10.1055/s-0031-1301067 article EN Journal of Reconstructive Microsurgery 2012-01-24

Micro-electronic industry has been boosting the capability of wireless mobile devices on full-scale. However, battery, as only power source most devices, is experiencing a relatively slow development. Therefore, how to optimally utilize limited battery energy under predefined performance requirement becomes critical issue. On other hand, it still unclear that capacity consumption allocated different working pattern specific video codec various tempo-spatial scales and parameters, which posed...

10.1109/glocom.2011.6134556 article EN 2011-12-01

Mobile machinery means a power-driven vehicle that is specifically designed and constructed to perform work on or off the road. To reduce nitrogen oxide (NOx) emissions come from mobile machinery, combination of physical model closed-loop control applied selective catalytic reduction (SCR) system. Based design variable cross-section extended exhaust structure, differential pressure measurement was achieved, flow based established. analysis heat mass transfer process SCR catalyst, prediction...

10.3390/pr10071374 article EN Processes 2022-07-14

Volume visualization plays a significant role in revealing important intrinsic patterns of 3D scientific datasets. However, these datasets are often large, making it challenging for interactive systems to deliver seamless user experience because high input latency that arises from I/O bottlenecks and limited fast memory resources with miss rates. To address this issue, we have proposed deep learning-based prefetching method called RmdnCache, which optimizes the data flow across hierarchy...

10.1109/tvcg.2024.3410091 article EN IEEE Transactions on Visualization and Computer Graphics 2024-01-01

Large language models (LLMs) are emerging as few-shot learners capable of handling a variety tasks, including comprehension, planning, reasoning, question answering, arithmetic calculations, and more. At the core these capabilities is LLMs' proficiency in representing understanding structural or semi-structural data, such tables graphs. Numerous studies have demonstrated that reasoning on tabular data graphs not only feasible for LLMs but also gives promising research direction which treats...

10.48550/arxiv.2411.01807 preprint EN arXiv (Cornell University) 2024-11-04

Considering the challenges posed by space and time complexities in handling extensive scientific volumetric data, various data representations have been developed for analysis of large-scale data. Multivariate functional approximation (MFA) is an innovative model designed to tackle substantial analysis. It computes values derivatives with high-order accuracy throughout spatial domain, mitigating artifacts associated zero- or first-order interpolation. However, slow query through MFA makes it...

10.1109/bigdata59044.2023.10386434 article EN 2021 IEEE International Conference on Big Data (Big Data) 2023-12-15

We report the use of second dorsal metacarpal artery-based bilobed island flap harvested from index and middle fingers for thumb reconstruction. From October 2006 to March 2008, was performed in 13 hands patients (10 males 3 females). The mean age at time operation 45 years (range, 38 57 years). flaps ranged size 2.1 × 2.5 cm 4.2 3.2 cm. were 4.7 3.0 pedicle length 6.5 5.1 8.0 cm). Flap survival achieved all cases. At final follow-up (mean 43 months; range, 36 52 months), static two-point...

10.1055/s-0031-1289164 article EN Journal of Reconstructive Microsurgery 2011-09-29
Coming Soon ...