Hendrik Thoen

ORCID: 0000-0002-1919-2642
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Medical Imaging Techniques and Applications
  • Radiation Detection and Scintillator Technologies
  • Advanced Radiotherapy Techniques
  • Lung Cancer Diagnosis and Treatment
  • Advanced MRI Techniques and Applications
  • Atomic and Subatomic Physics Research
  • Advanced X-ray and CT Imaging
  • Atrial Fibrillation Management and Outcomes
  • Radiomics and Machine Learning in Medical Imaging
  • Esophageal Cancer Research and Treatment
  • Cardiac Structural Anomalies and Repair
  • Cardiac tumors and thrombi
  • Cardiovascular Issues in Pregnancy
  • Ureteral procedures and complications
  • Hepatitis C virus research
  • Congenital Heart Disease Studies
  • Tuberous Sclerosis Complex Research
  • Venous Thromboembolism Diagnosis and Management
  • Cardiac electrophysiology and arrhythmias
  • Lung Cancer Research Studies
  • Infective Endocarditis Diagnosis and Management
  • Drug-Induced Hepatotoxicity and Protection
  • Lung Cancer Treatments and Mutations
  • Radiopharmaceutical Chemistry and Applications
  • Cardiac pacing and defibrillation studies

ZNA Middelheim Hospital
2024

Universitair Ziekenhuis Brussel
2024

Vrije Universiteit Brussel
2024

Ghent University Hospital
2015-2021

Ghent University
2012-2014

iMinds
2013-2014

The optimization of a whole-body PET system remains challenging task, as the imaging performance is influenced by complex interaction different design parameters. However, it not always clear which parameters have largest impact on image quality and are most eligible for optimization. To determine this, we need to be able assess their influence quality. We performed Monte-Carlo simulations scanner predict three detector parameters: TOF resolution, transverse pixel size depth-of-interaction...

10.1088/0031-9155/58/18/6459 article EN Physics in Medicine and Biology 2013-09-03

Background: Adding electroanatomical left atrial (LA) voltage mapping to cryoballoon ablation (CBA) improves validation of acute pulmonary vein isolation (PVI). Aims: To determine whether the addition can improve outcome and PVI durability. Methods: One-year PV reconnection (PVR) rate at first repeat were studied in 400 AF patients a propensity-matched analysis (age, type, CHA2DS2-VASc score) between Achieve catheter-guided CBA with additional EnSite LA maps performed pre- post-CBA (mapping...

10.3390/jcdd11020057 article EN cc-by Journal of Cardiovascular Development and Disease 2024-02-06

The performance of Digital Silicon Photomultipliers (dSiPM) coupled to a LYSO array containing 15×15 pixels with size 2×2×22 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> is evaluated determinate their potential for whole body Time Flight (TOF) PET scanners. detector are smaller in than the light sensors and therefore spreading required determine crystal where interaction occurred. A guide 1 was used spread neighbor logic (NL)...

10.1109/nssmic.2012.6551644 article EN 2012-10-01

Non-bacterial thrombotic endocarditis is characterized by the presence of sterile vegetations on a cardiac valve. We present case multi-territory stroke caused embolism non-bacterial aortic valve endocarditis, leading to diagnosis prostate adenocarcinoma with bone metastases.A 66-year-old patient was diagnosed pulmonary embolism, first attributed an asymptomatic coronavirus disease 2019 infection. Edoxaban started, which discontinued patient. Four weeks later, he presented subacute vertigo...

10.1093/ehjcr/ytab471 article EN cc-by-nc European Heart Journal - Case Reports 2021-11-19

Abstract Background Pocket hematoma (PH) is one of the most common complications after cardiovascular implantable electronic device (CIED) implantation resulting in an up to 9 times higher risk for CIED infections.(1) Different preventive strategies have been proposed with mixed results. Current standard care consists elastic adhesive tape leaving 2 major disadvantages: unpredictable pressure on pocket and inability visually assess bandage applied. Aim To evaluate safety effectiveness a...

10.1093/eurheartj/ehae666.426 article EN European Heart Journal 2024-10-01

Simeprevir is een nieuw geneesmiddel dat gebruikt wordt in de curatieve behandeling van hepatitis C, genotype 1 en 4. Het toegediend combinatie met peginterferon-alfa ribavirine of interferonvrije sofosbuvir. In deze casus beschrijven we het optreden ernstige fototoxiciteit bij patiente C behandeld simeprevir Fototoxiciteit gekende bijwerking simeprevir. Tijdens dan ook voorzichtigheid geboden aanbevolen om indien nodig voldoende zonwerende middelen te gebruiken overmatige blootstelling aan...

10.47671/tvg.72.21.2002215 article NL Tijdschrift voor Geneeskunde 2016-01-01

Abstract Patients with adult congenital heart disease are born structural defects who survived into adulthood. Occasionally, complex lesions remain undiagnosed, potentially causing substantial cardiovascular health problems at young age. Here, the case is presented of a patient subacute failure 1 week postpartum, revealing diagnosis aortic coarctation (CoA) patent ductus arteriosus (PDA). A 34‐year‐old woman to emergency department severe hypertension and exercise‐related dyspnoea...

10.1002/ehf2.12868 article EN cc-by-nc ESC Heart Failure 2020-06-25
Coming Soon ...