Yu Niu

ORCID: 0000-0003-2380-1006
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Lipid Membrane Structure and Behavior
  • Advanced biosensing and bioanalysis techniques
  • Advanced Biosensing Techniques and Applications
  • thermodynamics and calorimetric analyses
  • Energy Efficient Wireless Sensor Networks
  • Analytical Chemistry and Sensors
  • Pulsars and Gravitational Waves Research
  • Mobile Ad Hoc Networks
  • Microfluidic and Bio-sensing Technologies
  • Molecular Junctions and Nanostructures
  • Advanced materials and composites
  • Advanced ceramic materials synthesis
  • Conducting polymers and applications
  • Force Microscopy Techniques and Applications
  • Antimicrobial Peptides and Activities
  • Monoclonal and Polyclonal Antibodies Research
  • Electrochemical sensors and biosensors
  • Adaptive optics and wavefront sensing
  • Geophysics and Gravity Measurements
  • Powder Metallurgy Techniques and Materials
  • Metallurgical Processes and Thermodynamics
  • Semiconductor materials and interfaces
  • Geophysics and Sensor Technology
  • Advanced Measurement and Metrology Techniques
  • Gamma-ray bursts and supernovae

Taiyuan University of Technology
2024

Institute of Mechanics
2013-2022

Chinese Academy of Sciences
2013-2022

University of Chinese Academy of Sciences
2009-2022

Nanjing University
2020

Ludong University
2014

University of Science and Technology of China
2009-2013

Kyung Hee University
2006-2011

Institute of Metal Research
1999

University of Genoa
1999

Abstract In this perspective, we outline that a space borne gravitational wave detector network combining LISA and Taiji can be used to measure the Hubble constant with an uncertainty less than 0.5% in ten years, compared of ground based detectors which within 2% next five years by standard siren method. is Chinese detection mission planned for launch early 2030 s. The pilot satellite Taiji-1 has been launched August 2019 verify feasibility Taiji. results few technologies tested on are...

10.1038/s42005-021-00529-z article EN cc-by Communications Physics 2021-02-24

Abstract We report a straightforward and reproducible electrochemical approach to develop polydopamine-ethanolamine (ePDA-ETA) films be used as immunosensing interfaces. ETA is strongly attached polydopamine during the potentiodynamic electropolymerization of dopamine. The great advantage methods generate oxidized species (quinones), which can readily react with amine groups present in solution, subsequent incorporation this molecule polymer. presence its effect on electrosynthesis was...

10.1038/s41598-021-81816-1 article EN cc-by Scientific Reports 2021-01-26

Analysis of trace low molecular weight (LMW) proteins in serum using the label-free imaging ellipsometry (IE) immunosensor is still a challenge due to lack an effective signal amplification strategy and serious nonspecific adsorption. Herein we have developed sandwich strategy-mediated IE (SSIE) enable immunodetection LMW protein biomarkers samples. We first found that weak binding affinity insufficient surface amount density ligand are two important factors which hinder detection...

10.1021/acs.analchem.8b00888 article EN Analytical Chemistry 2018-05-30

Energy efficiency and balancing is one of the primary challenges for wireless sensor networks (WSNs) since tiny nodes cannot be easily recharged once they are deployed. Up to now, many energy efficient routing algorithms or protocols have been proposed with techniques like clustering, data aggregation location tracking etc. However, them aim minimize parameters total consumption, latency etc., which cause hotspot partitioned network due overuse certain nodes. In this paper, a Distance-based...

10.3390/s101009493 article EN cc-by Sensors 2010-10-21

Carbon disulfide (CS2) can spontaneously react with amine groups to form dithiocarbamates on gold surface, providing the possibility immobilize some compounds primary or secondary in one step. Using this principle, an immunosensor interface prepared for immunoglobulin G (IgG) sensing surface toward anti-IgG has been fabricated first time by simply immersing slides into a mixed aqueous solution of CS2 and protein A, followed incubation solution. The reaction between A UV–vis spectroscopy,...

10.1021/la303032f article EN Langmuir 2012-12-04

10.37188/cjlcd.2024-0175 article EN Chinese Journal of Liquid Crystals and Displays 2025-01-01

Summary. A biosensor based on imaging ellipsometry (BIE) has been developed and validated in 169 patients for detecting five markers of hepatitis B virus (HBV) infection. The methodology established to pave the way clinical diagnosis, including ligand screening, determination sensitivity, set‐up cut‐off values (CoVs) comparison with other methods. matrix assay method was screening. CoVs HBV were derived help receiver operating characteristic curves. Enzyme‐linked immunosorbent (ELISA)...

10.1111/j.1365-2893.2009.01123.x article EN Journal of Viral Hepatitis 2009-03-26

A biosensor based on high spatial resolution imaging ellipsometry has been studied to examine its role in the rapid detection and analysis of tropomyosin allergen existing crustaceans. This methodology established for includes ligand screening, determination sensitivity, a comparison with traditional methods. Three kinds monoclonal antibodies (2F9, 4C7, 2H6) known have bioactivity against were screened separately immobilized as ligands silicon wafer surface, thus allowing them capture...

10.1021/ac303783j article EN Analytical Chemistry 2013-03-21

The main issues of imaging ellipsometry-based biosensing for small molecules are the low sensitivity and narrow detection range due to molecular weight that results in a negligible signal. To meet this challenge, we theoretically investigated deciding factors ellipsometry signal further applied theory guide design biosensor using metal nanoparticles have high dielectric constant. Significant amplification effects can be achieved by nanoparticle labels including magnetic gold nanoparticles....

10.1021/acs.analchem.9b00846 article EN Analytical Chemistry 2019-05-03

To guarantee a smooth in-orbit space gravitational wave detection for the Taiji mission, semi-physical simulation test of inter-satellite laser interference is carried out. The consists three aspects: establishment link, interferometry ranging, and environment. With designed specifications platform, results can be obtained. Based on test, risks technology mitigated, laying solid foundation successful waves.

10.3390/app11177872 article EN cc-by Applied Sciences 2021-08-26

International Journal of Modern Physics AVol. 36, No. 11n12, 2102002 (2021) No AccessTaiji program in space for gravitational universe with the first run key technologies test Taiji-1The Taiji Scientific Collaboration, Yue-Liang Wu, Zi-Ren Luo, Jian-Yu Wang, Meng Bai, Wei Bian, Hai-Wen Cai, Rong-Gen Zhi-Ming Jin Cao, Bin Chen, Di-Jun Guang-Feng Kun Ling Li-Sheng Ming-Wei Wei-Biao Yan Ze-Yi Yi-Xing Chi, Lin-Xiao Cong, Jian-Feng Deng, Xiao-Qin Xiao-Long Dong, Li Duan, Da Fan, Sen-Quan...

10.1142/s0217751x21020024 article EN International Journal of Modern Physics A 2021-04-30

In this paper, we primary focus on prolonging the network lifetime of Wireless Sensor Networks (WSN), since small, portable batteries integrated into sensor chips can not be re-charged easily from an economical point view. We first made a further analysis about relationship between energy consumption and hop number. Then, optimal number is deduced for minimizing during multi-hop transmission. The importance to usually neglected by many routing protocols. fact, considerable amount saved if...

10.1109/sitis.2007.145 article EN 2007-12-01

Cytomegalovirus (CMV) is the most common infectious cause of mental disability in newborns developed countries. There an urgent need to establish early detection and high-throughput screening method for CMV infection using portable devices.An antibody analysis reported identification antibodies serum a biosensor based on high spatial resolution imaging ellipsometry (BIE). antigen (CMV-3A) was immobilized silicon wafers used capture serum. An against human immunoglobulin G (anti-IgG) confirm...

10.1371/journal.pone.0136253 article EN cc-by PLoS ONE 2015-08-21

10.1016/s1003-6326(10)60132-x article EN Transactions of Nonferrous Metals Society of China 2009-12-01
Coming Soon ...