Mohan Li

ORCID: 0000-0001-7677-0675
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Medical Imaging Techniques and Applications
  • Photoacoustic and Ultrasonic Imaging
  • Radiation Detection and Scintillator Technologies
  • Corneal surgery and disorders
  • Guidance and Control Systems
  • Adventure Sports and Sensation Seeking
  • Glaucoma and retinal disorders
  • Advanced Semiconductor Detectors and Materials
  • Optical Imaging and Spectroscopy Techniques
  • Ophthalmology and Visual Impairment Studies
  • Microwave Dielectric Ceramics Synthesis
  • Hydrogels: synthesis, properties, applications
  • Electromagnetic Launch and Propulsion Technology
  • Wound Healing and Treatments
  • Structural Health Monitoring Techniques
  • Radiomics and Machine Learning in Medical Imaging
  • Advanced Adaptive Filtering Techniques
  • Laser-Matter Interactions and Applications
  • Atomic and Subatomic Physics Research
  • Multiferroics and related materials
  • Ultrasound and Hyperthermia Applications
  • Electrical and Bioimpedance Tomography
  • Non-Invasive Vital Sign Monitoring
  • Photonic Crystal and Fiber Optics
  • Aviation Industry Analysis and Trends

Beijing Information Science & Technology University
2022-2023

Second Hospital of Anhui Medical University
2018-2023

Anhui Medical University
2018-2023

University of California, San Diego
2021-2023

Shenyang Pharmaceutical University
2022

University of Illinois Urbana-Champaign
2018-2020

Beijing Urban Systems Engineering Research Center
2018

Northwestern Polytechnical University
2015

McGill University
2011

Abstract Continuous imaging of cardiac functions is highly desirable for the assessment long-term cardiovascular health, detection acute dysfunction and clinical management critically ill or surgical patients 1–4 . However, conventional non-invasive approaches to image function cannot provide continuous measurements owing device bulkiness 5–11 , existing wearable devices can only capture signals on skin 12–16 Here we report a ultrasonic continuous, real-time direct assessment. We introduce...

10.1038/s41586-022-05498-z article EN cc-by Nature 2023-01-25

Serial assessment of the biomechanical properties tissues can be used to aid early detection and management pathophysiological conditions, track evolution lesions evaluate progress rehabilitation. However, current methods are invasive, only for short-term measurements, or have insufficient penetration depth spatial resolution. Here we describe a stretchable ultrasonic array performing serial non-invasive elastographic measurements up 4 cm beneath skin at resolution 0.5 mm. The conforms human...

10.1038/s41551-023-01038-w article EN cc-by Nature Biomedical Engineering 2023-05-01

Abstract Electronic patches, based on various mechanisms, allow continuous and noninvasive monitoring of biomolecules the skin surface. However, to date, such devices are unable sense in deep tissues, which have a stronger faster correlation with human physiological status than those Here, we demonstrate photoacoustic patch for three-dimensional (3D) mapping hemoglobin tissues. This integrates an array ultrasonic transducers vertical-cavity surface-emitting laser (VCSEL) diodes common soft...

10.1038/s41467-022-35455-3 article EN cc-by Nature Communications 2022-12-15

Depth-of-interaction (DOI) capability is important for achieving high spatial resolution and sensitivity in dedicated organ small animal positron emission tomography (PET) scanners. The dual-ended readout one of the common methods that can achieve good DOI resolution. aim this study to evaluate a detector based on silicon photomultiplier (SiPM) TOFPET2 application-specific integrated circuit (ASIC). 4 lutetium–yttrium oxyorthosilicate (LYSO) units, each unit contained 6 LYSO crystals,...

10.1088/1361-6560/ab3866 article EN Physics in Medicine and Biology 2019-08-05

Recent progress with Cadmium Zinc Telluride (CZT) radiation sensors grown by the traveling heater method (THM) at Kromek is reported. Large volume monolithic pixelated detectors, 40×40×15 mm

10.1117/12.2321244 article EN 2018-09-13

The tumor-involved regions of head and neck cancer (HNC) have complex anatomical structures vital physiological roles. As a consequence, there is need for high sensitivity spatial resolution dedicated HNC PET scanner. purpose this article to evaluate optimize system design that includes detecting materials geometries. For the material, two scanners with same two-panel geometry based on cadmium zinc telluride (CZT) lutetium-yttrium oxyorthosilicate (LYSO) were evaluated. geometry, four CZT...

10.1109/trpms.2020.2964293 article EN cc-by IEEE Transactions on Radiation and Plasma Medical Sciences 2020-01-08

The effectiveness of cycloplegia in delaying the progression myopia and its application refractive examination children have been extensively studied, but there are still few studies on effects atropine/tropicamide ocular biological parameters. Therefore, purpose this study was to explore children's parameters different age groups differences between them.This a prospective observational which all school were examined for dioptres outpatient clinic, 1% atropine or tropicamide used treatment....

10.1186/s12886-023-02840-5 article EN cc-by BMC Ophthalmology 2023-03-13

In this paper we experimentally demonstrate a femtosecond all-polarization- maintaining laser amplifier in an all-fiber scheme, which consists of mode-locked oscillator and two-stage amplifier. A hybrid method dispersion compensation is proposed based on fiber two Bragg gratings with different group velocity dispersion. The output pulse from the 57 fs average power 150 mW repetition rate 60 MHz, corresponding to peak 38.6 kW. By evaluation shaping, one third was compensated by pair gratings,...

10.1016/j.rio.2023.100408 article EN cc-by-nc-nd Results in Optics 2023-03-11

Near-space airships are high-end that being vigorously developed in the aerospace industry. It has important application value telecommunication, surveillance, monitoring, remote sensing, and exploration fields. The envelope is key component provides lift to airship. Online monitoring of status critical ensuring airship performance, safety, reliability. However, online 3D shape strain still a challenging task. A hybrid multi-core single-core fiber-optic method with temperature...

10.1364/ao.465148 article EN Applied Optics 2022-10-07

The traditional integrated guidance and control (IGC) method only considers the coupling between attitude loop loop. When intercepting a target with high maneuver or traversal speed, semi-strapdown missiles needs large adjustment to get enough seeker is likely lose This paper coordinator stable tracking. First, IGC model containing loop, tracking established. uncertainties of aerodynamic parameters are also considered. Then, back-stepping proposed based on active disturbance rejection...

10.23919/chicc.2018.8482808 article EN 2018-07-01

In this paper, a mathematical model of dynamic task schedule based on an anytime algorithm is proposed. The factors that affect the deadline opponents are studied. We construct according to minimize surplus threat and maximize attack value. By using time utility can give decisions timely coordinately for known unknown targets. Balancing decision efficiency, quickly. applied real-time weapon-target assignment (DWTA) problem. simulation results show efficiently DWTA problems.

10.1109/ihmsc.2015.101 article EN 2015-08-01

The observation vectors in traditional coarse alignment contain random noise caused by the errors of inertial instruments, which will slow down convergence rate. To solve above problem, a real-time reduction method, sliding fixed-interval least squares (SFI-LS), is devised to depress vectors. In this paper, square improved approach, applied for reduction. order achieve better-performed alignment, proposed method utilized de-noise First, principles SFI-LS algorithm and are devised. A...

10.32604/cmc.2019.06406 article EN Computers, materials & continua/Computers, materials & continua (Print) 2019-01-01

BGP monitors are currently the main data resource of AS-level topology measurement, and integrity measurement result is limited to location such monitors. However, there no work conduct a comprehensive study range results for single monitor. In this paper, we take first step describe observed each To that end, investigate construction theoretical up-limit measured monitor based on valley-free model, then evaluate individual parts by comparing with actually data. We find that: 1) more than...

10.32604/cmc.2020.06319 article EN Computers, materials & continua/Computers, materials & continua (Print) 2020-01-01

Abstract Electronic patches, based on various mechanisms, allow continuous and noninvasive monitoring of biomolecules the skin surface. However, to date, such devices have been unable sense in deep tissues, which a stronger faster correlation with human physiological status. Here, we demonstrate photoacoustic patch for three-dimensional (3D) mapping hemoglobin tissues. This integrates an array ultrasonic transducers vertical-cavity surface-emitting laser (VCSEL) diodes common soft substrate....

10.21203/rs.3.rs-558432/v1 preprint EN cc-by Research Square (Research Square) 2021-07-02

Objectives Poor follow-up after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) is common general clinical practice. We aimed to assess the surgical outcomes of patients with poor compliance FS-LASIK but who returned clinic additional prompting at a 1-year visit. also compared their those unprompted. Design Retrospective and observational study. Setting An urban tertiary hospital China. Participants reviewed medical records myopic underwent binocular FS-LASIK. These were all...

10.1136/bmjopen-2018-021702 article EN cc-by-nc BMJ Open 2018-11-01
Coming Soon ...