Giuseppe Allocca

ORCID: 0000-0002-2274-2131
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Cardiac Arrhythmias and Treatments
  • Cardiac electrophysiology and arrhythmias
  • Cardiac pacing and defibrillation studies
  • Atrial Fibrillation Management and Outcomes
  • ECG Monitoring and Analysis
  • Cardiovascular Effects of Exercise
  • Ion channel regulation and function
  • Venous Thromboembolism Diagnosis and Management
  • Cardiovascular Function and Risk Factors
  • Metabolism and Genetic Disorders
  • Preterm Birth and Chorioamnionitis
  • Cardiac Imaging and Diagnostics
  • Sports injuries and prevention
  • Maternal and Perinatal Health Interventions
  • Fatty Acid Research and Health
  • Infective Endocarditis Diagnosis and Management
  • Endometriosis Research and Treatment
  • Viral Infections and Immunology Research
  • Gynecological conditions and treatments
  • Neonatal Respiratory Health Research
  • Global Health Care Issues
  • Birth, Development, and Health
  • Cardiomyopathy and Myosin Studies
  • Climate Change and Health Impacts
  • Cardiac Valve Diseases and Treatments

Ospedale di Santa Maria dei Battuti
2017-2024

InnovaPuglia
2008-2021

Casa di Cura Villa Garda
2019-2021

Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico
2018-2021

University of Milan
2018-2021

Presidio Ospedaliero
2020

John Wiley & Sons (United States)
2020

Hudson Institute
2020

Northwestern University
2020

Ospedale Civile di Venezia
2019-2020

Risk stratification in individuals with type 1 Brugada electrocardiogram (ECG) pattern (type ECG) for primary prevention of sudden death (SD).Three hundred and twenty patients (258 males, median age 43 years) ECG were enrolled. No patient had previous cardiac arrest. Fifty-four per cent a spontaneous 46% drug-induced ECG. One-third syncope, two-thirds asymptomatic. Two forty-five underwent electrophysiologic study (EPS) 110 received an implantable defibrillator (ICD). During follow-up...

10.1093/eurheartj/ehq381 article EN European Heart Journal 2010-10-26

Analysis of right ventricular (RV) regional dysfunction by cardiac magnetic resonance (CMR) imaging in arrhythmogenic RV cardiomyopathy (ARVC) may be inadequate because the complex contraction pattern RV. Aim this study was to determine use strain and dyssynchrony assessment ARVC using feature-tracking CMR analysis.Thirty-two consecutive patients with referred were included. Thirty-two idiopathic outflow tract arrhythmias 32 control subjects, matched for age sex group, included comparison...

10.1161/circimaging.115.003647 article EN Circulation Cardiovascular Imaging 2015-11-01

The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation, which involves three incisions and a pocket, is associated with possible complications, including inappropriate interventions. aim of this prospective multicenter study was to evaluate the efficacy safety an alternative intermuscular two-incision S-ICD implantation.The population included 36 consecutive patients (75% male, mean age 44 ± 12 years [range 20-69]) who underwent implantation...

10.1111/pace.12987 article EN cc-by-nc-nd Pacing and Clinical Electrophysiology 2016-12-10

BackgroundAlthough the effects of air pollution on mortality have been clearly shown in many epidemiological and observational studies, pro-arrhythmic remain unknown. We aimed to assess short-term ventricular arrhythmias a population high-risk patients with implantable cardioverter-defibrillators (ICDs) or cardiac resynchronisation therapy defibrillators (ICD-CRT).MethodsIn this prospective multicentre study, we assessed 281 (median age 71 years) across nine centres Veneto region Italy....

10.1016/s2542-5196(17)30020-7 article EN cc-by-nc-nd The Lancet Planetary Health 2017-05-01

The recently developed second-generation subcutaneous implantable cardioverter defibrillator (S-ICD) and the intermuscular two-incision implantation technique demonstrate potential favorable features that reduce inappropriate shocks complications. However, data concerning large patient populations are lacking. aim of this multicentre prospective study was to evaluate safety outcome S-ICD using in a population study.

10.1111/jce.13894 article EN cc-by-nc Journal of Cardiovascular Electrophysiology 2019-03-03

ABSTRACT Background Recent advancements in ultra‐high‐density mapping (UHDM) featuring automated functionalities have enhanced our understanding of micro‐reentrant atrial tachycardias (mAT) circuits and the precise localization origin. Purpose To evaluate diagnostic support provided by an UHDM algorithm guiding ablation mATs. Methods Consecutive patients eligible for AT 22 Italian centers were prospectively enrolled. All ATs comprehensively mapped either left or right atrium utilizing...

10.1111/jce.16563 article EN Journal of Cardiovascular Electrophysiology 2025-01-30

Pacemaker leads may impair tricuspid valve coaptation and they are a well‐known cause of mild regurgitation. Occasionally, right ventricular worsen regurgitation over time patients develop late‐onset symptoms right‐sided heart failure. The exact mechanism this clinical entity is rarely identifiable by 2D‐echocardiography only. This case report details patient with severe secondary to immobilization the anterior leaflet permanent pacing lead. was clarified real three‐dimensional...

10.1111/j.1540-8175.2007.00443.x article EN Echocardiography 2007-03-28

Supraventricular tachycardia may trigger atrial fibrillation (AF). The aim of the study was to evaluate prevalence supraventricular (SVT) inducibility in patients referred for AF ablation and effects SVT on recurrences.Two hundred fifty-seven (185 males; mean age: 53.4 ± 14.6 years) were studied. In all only relapses had been documented clinical history. Twenty-six (10.1%; 43.4 13.3 years; 17 males) inducible during electrophysiological underwent an targeted at suppression. Ablation...

10.1093/europace/euq327 article EN EP Europace 2010-09-10

Electroanatomic Mapping for CRT Implantation Registry Introduction Cardiac resynchronization therapy (CRT) device implantation guided by an electroanatomic mapping system (EAMS) is emerging technique that may reduce fluoroscopy and angiography use provide information on coronary sinus (CS) electrical activation. We evaluated the outcome of EAMS‐guided in a multicenter registry. Methods During period 2011–2014 we enrolled 125 patients (80% males, age 74 [71–77] years) who underwent using...

10.1111/jce.13120 article EN Journal of Cardiovascular Electrophysiology 2016-11-09

This study was designed to assess the prognostic value of clinical and electrocardiographic parameters in Brugada syndrome (BrS). The population included 272 consecutive patients (82% males; mean age 43 ± 12 years), with either a spontaneous (n = 137, 50%) or drug-induced 135, Type 1 electrocardiogram (ECG) pattern. combined endpoint sudden cardiac death (SCD), arrest, appropriate intervention implantable cardioverter-defibrillator (ICD). A first-degree atrioventricular (AV) block (PR 219 17...

10.1093/europace/euy144 article EN EP Europace 2018-07-06

All available studies that have addressed the issue of risk stratification in patients with type 1 Brugada electrocardiographic (ECG) pattern considered a combined end point constituted by implantable cardioverter-defibrillator-recorded fast ventricular arrhythmias (ICD-FVA) and sudden death (SD) without ICD.As ICD-FVA are only surrogate SD, we tried to focus on prognostic value classical factors separating from those ICD who suffered SD.We made cumulative analysis largest studies. Studies...

10.1016/j.hrthm.2013.10.039 article EN cc-by-nc-nd Heart Rhythm 2013-10-24

Frequent ventricular premature beats (VPBs) may be discovered during preparticipation screening in asymptomatic apparently healthy athletes. Some authors hypothesize that they a manifestation of 'athlete's heart' and suggest deconditioning period, which should document regression arrhythmias, to exclude concealed disease.To test this hypothesis, we analysed 87 athletes with frequent VPB (>100/24 h). Of these, 44 (group D) underwent at least 3 months' detraining, whereas 43 C) continued...

10.2459/jcm.0b013e32834102ea article EN Journal of Cardiovascular Medicine 2010-12-08

Atrial tachycardia/fibrillation (AT/AF) episodes are common in implantable cardioverter-defibrillator (ICD) recipients and can be undetected by standard single-chamber devices. This study aims to explore whether a single-lead ICD with an atrial dipole (ICD DX; BIOTRONIK SE & Co, Berlin, Germany) could improve the AT/AF diagnosis management as compared VR).We selected patients without history from THINGS registry which included consecutive implanted for indications. The VR DX groups 236...

10.1111/jce.14396 article EN Journal of Cardiovascular Electrophysiology 2020-02-17

To assess accuracy and reproducibility of real time simultaneous triplane echocardiography (RT3PE) for the assessment left ventricular (LV) volumes ejection fraction (EF) using cardiac magnetic resonance (CMR) as a reference method.A total 24 patients with various degrees LV dysfunction (EF from 36 to 57%) in sinus rhythm good image quality were enrolled study. Digital loops apical views recorded standard two-dimensional imaging RT3PE. Echocardiography CMR performed within 1 hour. RT3PE...

10.1111/j.1540-8175.2008.00762.x article EN Echocardiography 2008-11-27
Coming Soon ...