- Radiation Detection and Scintillator Technologies
- Advanced Radiotherapy Techniques
- Radiation Effects in Electronics
- Radiation Effects and Dosimetry
- Radiation Therapy and Dosimetry
- Biosensors and Analytical Detection
- bioluminescence and chemiluminescence research
- IoT-based Smart Home Systems
- Semiconductor materials and devices
- Advanced X-ray and CT Imaging
- Winter Sports Injuries and Performance
- Salivary Gland Disorders and Functions
- Aerospace and Aviation Technology
- Advanced Chemical Sensor Technologies
- Inertial Sensor and Navigation
- Advanced Optical Sensing Technologies
- Analytical Chemistry and Sensors
- Non-Invasive Vital Sign Monitoring
- Surface Modification and Superhydrophobicity
- COVID-19 diagnosis using AI
- Luminescence Properties of Advanced Materials
- Semiconductor Quantum Structures and Devices
- Lattice Boltzmann Simulation Studies
- SARS-CoV-2 detection and testing
- Heart Rate Variability and Autonomic Control
Universidad de Granada
2020-2024
Zero to Three
2021
Purpose The response to radiation typically used in radiotherapy treatments has been experimentally evaluated for three samples of two phototransistors (BPW85B and OP505A) PIN photodiodes types (VTB8440BH BPW34S). Methods To that end, a staggered irradiation cycle applied which included dose rate values from 0.81 4.87 cGy/s, achieving total absorbed 21.4 Gy. have irradiated with linear accelerator the relations between induced photocurrent average instantaneous rates, accumulated charge...
Salivary pH serves as a valuable and useful diagnostic marker for periodontal disease, it not only plays critical role in disease prevention but also its development. Typically, saliva sampling is collected by draining spitting into collection tubes or using swabs. In this study, we have developed Point-of-Care (POC) device situ determination of oral without the need complex instruments, relying solely on smartphone detection device. Our system utilizes non-toxic vegetable colourimetric...
The COVID-19 pandemic has highlighted the need for innovative approaches to its diagnosis. Here we present CoVradar, a novel and simple colorimetric method that combines nucleic acid analysis with dynamic chemical labeling (DCL) technology Spin-Tube device detect SARS-CoV-2 RNA in saliva samples. assay includes fragmentation step increase number of templates analysis, using abasic peptide probes (DGL probes) immobilized nylon membranes specific dot pattern capture fragments. Duplexes are...
Safe quality control of radiotherapy treatments lies in reliable dosimetric sensors. Currently, ionization chambers and solid-state diodes along with electrometers as readout systems are accomplishing this task. In work, we present a well-known low-cost semiconductor sensor, the light-dependent resistor (LDR), an alternative to existing sensing devices for dosimetry. To demonstrate this, complete characterization response radiation commercial LDRs has been conducted terms sensitivity,...
In skiing it is important to know how the skier accelerates and inclines skis during turn avoid injuries improve technique. The purpose of this pilot study with three participants was develop evaluate a compact, wireless, low-cost system for detecting inclination acceleration in field based on inertial measurement units (IMU). To that end, commercial IMU board placed each ski behind boot. With use an attitude heading reference algorithm included sensor board, orientation data were obtained...
The aim of this current work is to identify three different gears cross-country skiing utilizing embedded inertial measurement units and a suitable deep learning model. style studied was the skating during uphill, which involved gears: symmetric gear pushing with poles on both sides (G3) two asymmetric right side (G2R) or left (G2L). To monitor technique, (IMUs) were affixed skis, recording acceleration Euler angle data uphill tests performed by experienced skiers using under study....
The increasing production and extensive use of biodiesel in the latest years call for development fast cost-effective procedures point-of-care analysis. One main quality parameters is content diesel blends, which needs to conform regional legislations. In this work, a microfluidic device exploiting chemical derivatization alkyl esters detection by smartphone-based digital-image colorimetry was developed. It designed ensure proper experimental conditions derivatization, including reagent...
In this work, we present a ballistocardiographic (BCG) system for the determination of heart and breath rates activity user lying in bed. Our primary goal was to simplify analog digital processing usually required these kinds systems while retaining high performance. A novel sensing approach is proposed consisting white LED facing light detector. This detector provides precise measurements variations intensity incident due vibrations bed produced by subject's breathing, heartbeat, or...
The world of elite sports has always been characterized by intense competition, where victories are often determined minimal differences. This means that every little detail in the preparation top-level athletes is crucial to their performance at highest level. One most significant aspects monitor jumping capacity, as it enables measurement performance, progression, and helps prevent injuries. Herein, we present development a system capable measuring flight time height reached user,...
Wireless electronic platform for real-time flow monitoring in paper strips. Experimental/numerical study physical-based modelling of capillary-driven dynamics.
A commercial pMOS transistor (MOSFET), 3N163 from Vishay (USA), has been characterized as a low-energy proton beam dosimeter. The top of the samples' housing removed to guarantee that protons reached sensitive area, is, silicon die. Irradiations took place at National Accelerator Centre (Seville, Spain). During irradiations, transistors were biased improve sensitivity, and temperature was monitored activating parasitic diode MOSFET. Bias voltages 0, 1, 5, 10 V applied four sets three...
This paper presents research on methods for implementation of NFC technology into ESP32 based IoT systems. Two main are proposed, first with the commercial modules that incorporate built-in antenna and module is universal transceiver decoder, second method, where all integral parts system designed separately. Methods analyzed compared in terms feasibility, speed, resources cost, using specially developed tests. Tests consist multiple writing reading tasks from tag, smartphone. also examine...
This study investigates the relationship between sensitivity and temperature during irradiation in MOSFET dosimeters. Three samples of commercial lateral p-channel 3N163 were exposed to Cobalt-60 radiation at temperatures ranging from 8 75 °C. Results indicate that no thermal dependence was observed up a dose Gy.
Thermal effects are especially relevant in PIN photodiode dosimeters which dark current depends exponentially on temperature. To minimize this effect, a thermal compensation procedure is presented relying the diode structure itself, without requiring any external sensor or device. Under irradiation, periodically switched from reverse to forward polarization for device temperature estimation. This estimation based linear relationship between voltage and when biased at constant current. has...
COVID-19 pandemic has pointed out the strong need to continue promoting development of innovative approaches for rapid, safe handling and accurate molecular diagnosis SARS-CoV-2 infection. In this work, we have developed CoVradar, a novel colourimetric detection system that integrates nucleic acid analysis by dynamic chemistry labelling (DCL) technology with Spin-Tube devices allowing reverse dot-blot hybridization in an array format detect RNA within saliva specimens. The assay is designed...
Anna A. Oleshkevich, Specific features of change in enzymate activity