Adi Abulafia

ORCID: 0000-0002-5008-9432
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Corneal surgery and disorders
  • Ophthalmology and Visual Impairment Studies
  • Intraocular Surgery and Lenses
  • Glaucoma and retinal disorders
  • Ocular Surface and Contact Lens
  • Ocular Infections and Treatments
  • Corneal Surgery and Treatments
  • Retinal Diseases and Treatments
  • Ophthalmology and Visual Health Research
  • Retinal and Optic Conditions
  • Ergonomics and Musculoskeletal Disorders
  • Retinal and Macular Surgery
  • Protein Degradation and Inhibitors
  • Cerebral Venous Sinus Thrombosis
  • Ocular Diseases and Behçet’s Syndrome
  • Acne and Rosacea Treatments and Effects
  • Advanced Neuroimaging Techniques and Applications
  • Cardiac, Anesthesia and Surgical Outcomes
  • Advanced Measurement and Metrology Techniques
  • Scoliosis diagnosis and treatment
  • Traumatic Ocular and Foreign Body Injuries
  • Multiple Myeloma Research and Treatments
  • Facial Rejuvenation and Surgery Techniques
  • Myeloproliferative Neoplasms: Diagnosis and Treatment
  • Delphi Technique in Research

Shaare Zedek Medical Center
2017-2024

Hebrew University of Jerusalem
2017-2024

Tel Aviv University
2012-2022

Alcon (China)
2021-2022

Carl Zeiss (Germany)
2022

American Society of Colon and Rectal Surgeons
2022

University of Amsterdam
2021

Amsterdam University Medical Centers
2021

University Surgical Associates
2020

Assaf Harofeh Medical Center
2016-2018

To evaluate and compare the accuracy of formulas methods for calculating intraocular lens (IOL) power eyes with an axial length (AL) greater than 26.0 mm.Ein-Tal Eye Center, Tel-Aviv, Israel.Retrospective case series.The postoperative refraction results in myopic AL over mm were compared predicted refractions calculated using standard (Holladay 1, SRK/T, Hoffer Q, Haigis) optical IOL constants, User Group Laser Interference Biometry AL-adjustment method new-generation (Barrett Universal II,...

10.1016/j.jcrs.2014.06.033 article EN Journal of Cataract & Refractive Surgery 2015-02-21

Purpose To compare the accuracy of Barrett True-K formula with other methods available on American Society Cataract and Refractive Surgery (ASCRS) post-refractive surgery intraocular lens (IOL) power calculator for prediction IOL after previous myopic laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK). Setting Cullen Eye Institute, Baylor College Medicine, Houston, Texas, private practice, Mesa, Arizona, USA. Design Retrospective case series. Methods The was compared...

10.1016/j.jcrs.2015.11.039 article EN Journal of Cataract & Refractive Surgery 2016-03-01

To evaluate and compare the accuracy of 2 toric intraocular lens (IOL) calculators with or without a new regression formula.Ein-Tal Eye Center, Tel-Aviv, Israel, Lions Institute, Nedlands, Western Australia, Australia.Retrospective case series.A formula (Abulafia-Koch) was developed to calculate estimated total corneal astigmatism based on standard keratometry measurements. The error in predicted residual calculated by Alcon Holladay IOL adjustments Abulafia-Koch formula. These results were...

10.1016/j.jcrs.2016.02.038 article EN Journal of Cataract & Refractive Surgery 2016-05-01

Purpose To compare the accuracy of different methods that consider posterior corneal curvature in toric intraocular lens (IOL) calculations. Setting Ein-Tal Eye Center, Tel-Aviv, Israel. Design Retrospective comparative case series. Methods Consecutive cases IOL implantation and preoperative measurements by optical biometry with low-coherence reflectometry (OLCR) (Lenstar LS 900) a Scheimpflug camera (Pentacam) were retrospectively reviewed. Five calculation compared as follows: (1) anterior...

10.1016/j.jcrs.2015.11.036 article EN Journal of Cataract & Refractive Surgery 2016-02-01

To evaluate and compare the accuracy of different methods to measure predict postoperative astigmatism with toric intraocular lens (IOL) implantation.Ein-Tal Ophthalmology Center, Tel-Aviv, Israel.Retrospective case series.Postoperative corneal was measured 3 devices (IOLMaster 500; optical low-coherence reflectometry [OLCR]-based Lenstar LS 900; Atlas topographer) compared manifest astigmatic refractive outcome in patients IOLs. The error predicted residual calculated by vector analysis...

10.1016/j.jcrs.2014.08.036 article EN Journal of Cataract & Refractive Surgery 2015-05-01

PURPOSE: To evaluate and compare the accuracy of three toric intraocular lens (IOL) calculators using keratometry measurements derived from anterior corneal curvature direct posterior curvature. METHODS: Postoperative astigmatism was measured by IOLMaster (Carl Zeiss Meditec, Jena, Germany) Pentacam (Oculus Optikgeräte, Wetzlar, Germany). The data were processed Alcon, Holladay, Barrett IOL calculators. error in predicted residual (PredRA) calculated subtracting PredRA postoperative...

10.3928/1081597x-20150928-03 article EN Journal of Refractive Surgery 2015-10-01

To evaluate the accuracy of predicted refraction using multifocal intraocular lenses (IOLs) with power calculation based on two biometric devices and multiple IOL formulas.A retrospective study conducted in a private practice ophthalmology clinic.Seventy-three eyes 48 patients were evaluated.Consecutive cases that had undergone successful cataract surgery an implantation (SN6AD1, Alcon Laboratories, Inc., Fort Worth, TX, USA) by single surgeon enrolled. Patients meticulously screened for...

10.1111/ceo.12478 article EN Clinical and Experimental Ophthalmology 2014-12-10

PURPOSE: To compare the accuracy of different intraocular lens (IOL) calculation formulas available on American Society Cataract and Refractive Surgery (ASCRS) post-refractive surgery IOL power calculator for prediction multifocal after previous corneal refractive laser myopia. METHODS: An analysis comparison were performed three methods using surgically induced change in refraction (ie, Masket, Modified Barrett True-K formulas) no data Shammas, Haigis-L, No History formulas). The average...

10.3928/1081597x-20181119-01 article EN Journal of Refractive Surgery 2019-01-01

PURPOSE: To compare posterior corneal features and their discriminating power for differentiating normal corneas from subclinical keratoconus using the Placido dual-Scheimpflug analyzer. METHODS: Patients were retrospectively included in study. The preoperative right eyes of 79 patients imaged with a system stable postoperative LASIK follow-up minimum 36 months group compared to 39 contralateral topographically clinically evident fellow eye. surface variables measured categorized according...

10.3928/1081597x-20180823-02 article EN Journal of Refractive Surgery 2018-10-01

Purpose: To evaluate the long-term results of corneal collagen cross-linking (CXL) for treatment pediatric keratoconus and outcomes fellow untreated keratoconic eye in patients younger than 18 years old. Methods: A retrospective case analysis was performed on 88 eyes 44 aged or younger, with keratoconus, who underwent CXL at least 1 eye. Follow-up measurements, treated pair, taken up to 5 after treatment, were compared baseline values. Parameters included uncorrected distance visual acuity...

10.1097/ico.0000000000001629 article EN Cornea 2018-05-03

To evaluate the agreement in biometry measurements and intraocular lens (IOL) power calculations between 2 integrated swept-source optical coherence tomography (SS-OCT) tomography/biometry devices: Eyestar 900 Anterion.Tel Aviv Medical Center, Tel Aviv, Israel.Retrospective comparative study.113 eyes of 66 consecutive patients who were evaluated prior to cataract surgery using both devices on same visit included. Measurements axial length, anterior posterior keratometry, chamber depth,...

10.1097/j.jcrs.0000000000000974 article EN Journal of Cataract & Refractive Surgery 2022-05-24

To evaluate the accuracy of different intraocular lens (IOL) power calculation formulas available on American Society Cataract and Refractive Surgery calculator in calculating multifocal IOL eyes with previous hyperopic corneal refractive laser surgery.Retrospective case series.Amsterdam University Medical Center, Amsterdam, Retina Total Eye Care, Driebergen, Netherlands.This study compared 3 using historical data (ie, Masket, modified Barrett True-K) no Shammas, Haigis-L, True-K...

10.1016/j.jcrs.2018.12.006 article EN Journal of Cataract & Refractive Surgery 2019-02-28

Purpose: To assess the clinical relevance of routine preoperative spectral-domain optical coherence tomography (SD-OCT) for identifying macular pathologies in patients scheduled cataract surgery. Setting: Shaare-Zedek Medical Center, Jerusalem, Israel. Design: Retrospective case series. Methods: Consecutive patients, 50 years age and older, standard extraction surgery were enrolled from November 2017 to January 2018. All study underwent SD-OCT scanning before The scans reviewed by a retinal...

10.1097/j.jcrs.0000000000000389 article EN Journal of Cataract & Refractive Surgery 2020-08-20

Purpose: To evaluate the accuracy and usefulness of certain methods analyzing astigmatic vectors. Setting: Cullen Eye Institute, Baylor College Medicine, Houston, Texas. Design: Case samples. Methods: Using 2 sample cases for analysis corneal surgically induced astigmatism an actual toric intraocular lens (IOL) case, univariate analyses from ASSORT program were compared to double-angle plots preoperative postoperative prediction errors. Results: Certain figures misleading. For IOL some key...

10.1097/j.jcrs.0000000000000428 article EN Journal of Cataract & Refractive Surgery 2020-09-18

To obtain consensus on the key areas of burden associated with existing devices and to understand requirements for a comprehensive next-generation diagnostic device be able solve current challenges provide more accurate prediction intraocular lens (IOL) power presbyopia correction IOL success.Thirteen expert refractive cataract surgeons including three steering committee (SC) members constituted voting panel. Three rounds included Round 1 structured electronic questionnaire, 2 virtual...

10.2147/opth.s412847 article EN cc-by-nc Clinical ophthalmology 2023-07-01
Coming Soon ...