M. Kwiatkowski

ORCID: 0000-0003-0168-3512
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Particle Detector Development and Performance
  • Radiation Effects in Electronics
  • Particle Accelerators and Free-Electron Lasers
  • Advanced X-ray Imaging Techniques
  • Radiation Detection and Scintillator Technologies
  • Atomic and Molecular Physics
  • Medical Imaging Techniques and Applications
  • ZnO doping and properties
  • Advanced Photocatalysis Techniques
  • Copper-based nanomaterials and applications
  • Graphite, nuclear technology, radiation studies
  • Advanced Optical Sensing Technologies
  • Particle accelerators and beam dynamics
  • CCD and CMOS Imaging Sensors
  • Cancer Genomics and Diagnostics
  • Laser-induced spectroscopy and plasma
  • TiO2 Photocatalysis and Solar Cells
  • Water and Wastewater Treatment
  • Scientific Measurement and Uncertainty Evaluation
  • Advanced Nanomaterials in Catalysis
  • Advanced Chemical Physics Studies
  • Precipitation Measurement and Analysis
  • Chalcogenide Semiconductor Thin Films
  • Plant nutrient uptake and metabolism
  • Calibration and Measurement Techniques

SLAC National Accelerator Laboratory
2016-2019

Menlo School
2016-2019

University of Warsaw
1995-2017

Université de Bourgogne
2015-2017

Centre National de la Recherche Scientifique
2016-2017

Laboratoire Interdisciplinaire Carnot de Bourgogne
2015-2017

European Organization for Nuclear Research
2014-2016

Maison des Sciences de l’Homme de Dijon
2015

Technische Universität Berlin
1982

In this work, composite core–shell ZnO/TiO<sub>2</sub> materials were fabricated by deposition of TiO<sub>2</sub> layers <italic>via</italic> sol–gel method on ZnO nanorods hydrothermally grown ITO electrode.

10.1039/c5ta01087j article EN Journal of Materials Chemistry A 2015-01-01

ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three modes (high, medium and low) two auto-ranging (high-to-low medium-to-low). The first cameras are built around modules consisting of sensor flip-chip bonded 4 ASICs, resulting in 352 × 384 pixels 100 µm x each. We present results from extensive testing with FEL beams LCLS, measured noise floor...

10.1063/1.5084693 article EN AIP conference proceedings 2019-01-01

A second generation camera system has been developed and built at SLAC for use in experiments the Linac Coherent Light Source (LCLS). The is around ePix family of hybrid pixel detectors, with a focus on modularity mechanical, electrical, data acquisition interfaces, allowing versatile that can be quickly reconfigured. first compact, 155 mm × 52 box, an active area up to 35 38 mm, recording full frames over 540 kpixel rates excess 120 Hz. allows fast debugging development, providing test...

10.1063/1.4952919 article EN AIP conference proceedings 2016-01-01

The ePix100A camera is a 0.5 megapixel (704 x 768 pixels) for low noise x-ray detection applications requiring high spatial and spectral resolution. built around hybrid pixel detector consisting of 4 ePix100a ASICs ip-chip bonded to one sensor. pixels are 50 μm (active sensor size ~ 35:4mm 38:6 mm), with 180 eV rms, range 100 8 keV photons, current frame rate 240 Hz (with an upgrade path towards 10 kHz). This performance leads combining dynamic range, signal ratio, speed excellent linearity...

10.1117/12.2238136 article EN Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2016-09-30

OVER the past two decades momentum resolving spectrometers have revolutionized electron and ion spectroscopy. Momentum spectroscopy has enabled a new class of experiments in both laser based ultrafast sciences, x-ray [1]. The fundamental concept these is that time-of-arrival (ToA) position each fragment measured. From data vector particle can be calculated. So far delay-line detectors on microchannel plate (MCP) long wire anode been used which are severely limited their multi-hit capability...

10.1109/nssmic.2016.8069725 article EN 2016-10-01

A wide range current digitizer card is needed for the acquisition module of beam loss monitoring systems in CERN Injector Complex. The fully differential frequency converter allows measuring positive and negative input currents with a resolution 31 nA an integration window 2 μs. Increasing window, dynamic covers 21010 were upper part converted by directly voltage drop on resistor. key elements this design are integrator switches operated FPGA. circuit designed to avoid any dead time...

10.1088/1748-0221/9/02/c02011 article EN cc-by Journal of Instrumentation 2014-02-13

The high repetition rate of second generation FEL is pushing the requirements photon science x-ray cameras. In particular LCLS-II, planned upgrade LCLS, will be able to operate at a continuous 1 MHz. To exploit new possibilities this novel machine an program for ePix family detectors undergoing. ASICs integrate core functionalities Their architecture based on common platform composed random access analog matrix pixel with global shutter, fast parallel column readout. ePixHR represents and...

10.1109/nssmic.2018.8824482 article EN 2018-11-01

A beam of Mn+ ions in the ground level 3d5(a6S)4s a 7S3 and metastable 5S2 (9472 cm-1) was produced discharge Mn vapour. The were selectively excited by frequency-doubled radiation pulsed dye laser to levels 3d5(a6S)4p z 7PJ (J=2, 3) 3d5(a 6S)4p 5PJ (J=1, 2, 3). radiative lifetimes these measured time-resolved observation re-emitted fluorescence. results are compared with other experimental theoretical values.

10.1088/0022-3700/15/23/018 article EN Journal of Physics B Atomic and Molecular Physics 1982-12-14

THE SLAC Linac Coherent Light Source (LCLS) upgrade, known as LCLS-II, will provide extremely bright X-ray laser light at higher rate, moving from the actual 120 pulses per second (120 Hz) to 1 million (1 MHz). The facility operate in a soft range (250 eV - 2 keV), performing experiments wide of fields that are now impossible.

10.1109/nss/mic42101.2019.9059784 article EN 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) 2019-10-01

Risk is a fundamental consideration when designing electronic systems. For most systems view of risk can assist in setting design objectives, whereas both qualitative and quantitative understanding mandatory considering protection This paper gives an overview the risks due to stored magnetic beam energies high-energy physics, shows how risk-based approach be used new mitigating these risks, using lifecycle inspired by IEC 61508. Designing physics challenging as novel techniques are difficult...

10.48550/arxiv.1607.01574 preprint EN cc-by arXiv (Cornell University) 2016-01-01

Abstract Studying the electronic properties of small metallic particles Kubo and subsequently Denton, Mühlschlegel Scalapino recognized surprising effect that mean occupation numbers noninteracting fermions (electrons) are not given within canonical ensemble by usual expression Fermi‐Dirac statistics. The behave as if they colder observed deviations most significant in vicinity Fermi level. results our Monte Carlo simulations, well complementary numerical analytical very good agreement with...

10.1002/andp.19955070704 article EN Annalen der Physik 1995-01-01

10.11578/dc.20220711.10 article EN OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) 2018-03-16

10.11578/dc.20220726.4 article CA OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) 2022-02-24
Coming Soon ...