Ming Yang

ORCID: 0000-0001-8867-9211
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Antenna Design and Analysis
  • Advanced MRI Techniques and Applications
  • Energy Harvesting in Wireless Networks
  • Video Coding and Compression Technologies
  • Microwave Engineering and Waveguides
  • Electrical and Bioimpedance Tomography
  • Advanced Data Compression Techniques
  • Flow Measurement and Analysis
  • Antenna Design and Optimization
  • Medical Imaging Techniques and Applications
  • Advanced Neuroimaging Techniques and Applications
  • Sparse and Compressive Sensing Techniques
  • Ultrasound Imaging and Elastography
  • Advanced Antenna and Metasurface Technologies
  • Radiomics and Machine Learning in Medical Imaging
  • MRI in cancer diagnosis
  • Advanced X-ray and CT Imaging
  • Underwater Vehicles and Communication Systems
  • Advanced Vision and Imaging
  • Alzheimer's disease research and treatments
  • Advanced MIMO Systems Optimization
  • Full-Duplex Wireless Communications
  • Advanced Sensor and Control Systems
  • Piezoelectric Actuators and Control
  • Image and Video Quality Assessment

West Anhui University
2018-2025

Affiliated Hospital of Southwest Medical University
2025

Xi'an Technological University
2024

Second Affiliated Hospital of Nanjing Medical University
2017-2023

Bozhou People's Hospital
2014-2022

Beijing Institute of Technology
2017-2019

Anhui University
2018-2019

China National Institute of Standardization
2017-2019

Coventry University
2015-2018

Jilin Engineering Normal University
2018

Objective: Free-breathing abdomen imaging requires non-rigid motion registration of unavoidable respiratory in three-dimensional undersampled data sets. In this work, we introduce an image method based on the convolutional neural network (CNN) to obtain motion-free abdominal images throughout cycle. Methods: Abdominal were acquired from 10 volunteers using a 1.5 T MRI system. The signal was extracted central-space spokes, and reordered three bins according corresponding breathing signal....

10.1259/bjr.20170788 article EN British Journal of Radiology 2017-12-20

Abstract In this article, a novel multiple input output (MIMO) antenna with compact structure and diverse radiation patterns is designed for wireless communication device. Four monopole elements are placed orthogonally at the corner of substrate. A decoupling composed circular patch 4 L‐shaped branches counterclockwise printed on upper surface substrate to reduce coupling between elements. Due current parasitic patch, which was acquired by antenna, MIMO exhibits an omnidirectional pattern...

10.1002/mop.32334 article EN Microwave and Optical Technology Letters 2020-02-24

Industrial robots consume a considerable amount of energy in the manufacturing industry. As sustainable is one directions manufacturing, efficiency industrial should be considered. The consumption model key to analyze and improve robots. This article focuses on characteristic analysis modeling robot. inertial friction parameters which are base need identified. Since torque usually used for parameter identification may unavailable, we propose use software-simulated power data perform Then,...

10.1177/1687814018773852 article EN cc-by Advances in Mechanical Engineering 2018-05-01

A rehabilitation robot plays an important role in relieving the therapists’ burden and helping patients with ankle injuries to perform more accurate effective training. However, a majority of current robots are rigid have drawbacks terms complex structure, poor flexibility lack safety. Taking advantages pneumatic muscles’ good light weight, we developed novel two degrees freedom (2-DOF) parallel compliant actuated by muscles (PMs). To solve PM’s nonlinear characteristics during operation...

10.3390/s18010066 article EN cc-by Sensors 2017-12-28

We propose an inter mode decision scheme for P slices in the H264 video coding standard. Our initially exploits neighborhood information jointly with a set of skip conditions enhanced decision. It subsequently performs remaining macroblocks by using gentle smoothness constraints. For RD performance very close to standard, we achieve 35-58% reduction run times and 33-55% CPU cycles both rate controlled non versions H264. Compared other gradient based work that has been proposed as input gains...

10.1109/tbc.2005.846192 article EN IEEE Transactions on Broadcasting 2005-05-24

10.2528/pierc25022301 article EN Progress In Electromagnetics Research C 2025-01-01

Proliferation activity mapping is crucial for the guidance of first biopsy and treatment evaluation gliomas due to highly heterogenous nature glioma tumor. Here we propose demonstrate an ease-of-use way in vivo spatiotemporal proliferation by simply tracking transmembrane water dynamics with magnetic resonance imaging (MRI). Specifically, demonstrated that can accelerate transport cells. Method: The water-efflux rate (k io) measured water-exchange dynamic contrast-enhanced (DCE) MRI....

10.7150/thno.108479 article EN cc-by Theranostics 2025-03-24

In this paper a novel ultrasound tomography imaging system is presented. It employs relatively small number of transducers that produce fan-shaped beam profile to effectively insonify the cross-section. The impact on image quality due reduction discussed, and different approaches such as multiple receiver data acquisition nonlinear thresholding are explored. A prototype tomographic with only 36 has been constructed, processing rates up 100 frames per second have achieved using parallel...

10.1109/58.764834 article EN IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 1999-05-01

To satisfy the demand for 5G communication to smartphone terminal antennas in element quantity and isolation, an eight-element wideband MIMO antenna set of high isolation level is proposed. Each array a double-L consisting L-shaped slot 50 Ω microstrip line. The L formed by adding I-shaped open circuit directly side rectangular slot. In addition, arrays are located on long bezels both sides mobile phone motherboard, coupling feed made frequency range 3.6–4.7 GHz through line, so as cover NR...

10.3390/sym15030579 article EN Symmetry 2023-02-23

With conventional time-of-flight sonar ranging systems, it is difficult to obtain a high accuracy due the finite bandwidth of transducer used and serious acoustic attenuation in air for frequencies. In this paper multifrequency amplitude modulation (AM)-based system exploited information about high-resolution distance measurement robotic applications. The target obtained by measuring linear phase shift reflected waves with respect reference signal. order analyze error two theoretical...

10.1109/19.368084 article EN IEEE Transactions on Instrumentation and Measurement 1994-01-01

A compact wideband printed antenna with deca-band 4G/5G/WLAN for mobile phone devices is proposed in this paper. The complete structure composed of a monopole and coupling strip, occupying small C-shape PCB area 27 × 10.8 mm 2 . This antenna, which on FR4 substrate 0.8 thickness fed by coaxial cable, can provide three wide operating bandwidths that cover 685–1012 MHz, 1596–2837 3288–3613 MHz communication systems. gains total radiation efficiencies the low, middle, high bands are 1.4 dBi–2.5...

10.1155/2019/3209840 article EN cc-by International Journal of Antennas and Propagation 2019-09-10

To improve the performances of a rectangular-plate linear ultrasonic motor for specific applications, dual-frequency drive has been proposed and investigated. Through careful design rectangular piezoelectric ceramic plate, its first longitudinal resonant frequency coincides with second lateral bending is one-third higher frequency. When square-wave voltage used to motor, vibration modes are excited. Experimental results show that maximum thrust force velocity over 170% those obtained from...

10.1109/tuffc.2004.1386678 article EN IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 2004-12-01

Purpose Free‐breathing three‐dimensional (3D) abdominal imaging is a challenging task for MRI , as respiratory motion severely degrades image quality. One of the most promising self‐navigation techniques 3D golden‐angle radial stack‐of‐stars ( SOS ) sequence, which has advantages in terms speed, resolution, and allowing free breathing. However, streaking artifacts are still clearly observed reconstructed images when undersampling applied. This work presents novel reconstruction approach...

10.1002/mp.12870 article EN Medical Physics 2018-03-25

This paper deals with the development of a str- ategy for fast multi-object identification which utilizes time-of-flight(T0F) based ultrasonic linear array consisting commercially available inexpensive transduc- ers. By applying computer controlled delayed pulses to transducers, system can perform beam steering through scan range 0 +60 in programable angle steps. The has capability ranging from 60 step 2 time period 630 ms detecting single object(when maximum distance is less than 3.4...

10.1109/iros.1992.594236 article EN 2005-08-24

The development of an ultrasonic reflection tomography system is described. intended for the imaging two component flows (such as gas/water) inside pipes industrial processes. Data acquisition performed using a digital signal processor and network parallel processors perform image reconstruction. Real-time images are obtained at rates up to 55 frames per second 36 non-intrusive transducer elements in 4 inch pipe.

10.1049/el:19961059 article EN Electronics Letters 1996-08-15

Using a wide-beamwidth ultrasound transducer arrangement to measure the geometric position of plane reflectors is studied. The localization objects based on computation time flight (TOF) acoustic echoes by determination intersection point wave fronts; geometrical object then estimated. As no mechanical moving devices are involved in ranging process, and fewer TOF measurements required than that an active phased linear array, system features intrinsically high operational reliability fast...

10.1109/19.585438 article EN IEEE Transactions on Instrumentation and Measurement 1997-06-01

This paper proposes a compressive sensing (CS) method for radial Magnetic Resonance Imaging (MRI) using nonuniform fast fourier transform (NUFFT). With the Ultra-short Echo Time (UTE) technology, MRI can reduce scan time, artifacts, and achieve high imaging quality. We show that NUFFT-CS reconstruction from under-sampled k-space measurements achieves better image quality than zero-filling (ZF) approaches existing CS approach uses regridding. Experiments phantom animal samples have verified...

10.1109/isbi.2015.7164020 article EN 2022 IEEE 19th International Symposium on Biomedical Imaging (ISBI) 2015-04-01
Coming Soon ...