- Electromagnetic Fields and Biological Effects
- Wireless Body Area Networks
- Radio Astronomy Observations and Technology
- Energy Harvesting in Wireless Networks
- Superconducting and THz Device Technology
- Noise Effects and Management
- Astronomy and Astrophysical Research
- Astrophysics and Cosmic Phenomena
- Air Quality and Health Impacts
- Hearing Loss and Rehabilitation
- Cosmology and Gravitation Theories
- Health, Environment, Cognitive Aging
- Reproductive Biology and Fertility
- Gyrotron and Vacuum Electronics Research
- Geophysics and Gravity Measurements
- Kruppel-like factors research
- Immunotherapy and Immune Responses
- Power Line Communications and Noise
- Transgenic Plants and Applications
- Enzyme Catalysis and Immobilization
- Air Quality Monitoring and Forecasting
- Wireless Sensor Networks for Data Analysis
- Millimeter-Wave Propagation and Modeling
- Cancer Risks and Factors
- Monoclonal and Polyclonal Antibodies Research
UK Health Security Agency
2021-2024
Enterome (France)
2024
Université Paris-Saclay
2021
Commissariat à l'Énergie Atomique et aux Énergies Alternatives
2021
CEA Paris-Saclay
2021
Infectious Disease Models and Innovative Therapies
2021
Institut Carnot ARTS
2021
Public Health England
2013-2019
Universidad de Los Andes
2012
Cardiff University
2003-2006
Laboratory measurements have been carried out with examples of Wi-Fi devices used in UK schools to evaluate the radiofrequency power densities around them and total emitted powers. Unlike previous studies, a 20 MHz bandwidth signal analyzer was used, enabling whole be captured monitored. The radiation patterns laptops had certain similarities, including minimum toward torso user two maxima symmetrically opposed across vertical plane bisecting screen keyboard. would resulted from separate...
In recent decades, the possibility that use of mobile communicating devices, particularly wireless (mobile and cordless) phones, may increase brain tumour risk, has been a concern, given considerable in their by young people. MOBI-Kids, 14-country (Australia, Austria, Canada, France, Germany, Greece, India, Israel, Italy, Japan, Korea, Netherlands, New Zealand, Spain) case-control study, was conducted to evaluate whether phone (and resulting exposure radiofrequency (RF) extremely low...
Wireless phones (both mobile and cordless) emit not only radiofrequency (RF) electromagnetic fields (EMF) but also extremely low frequency (ELF) magnetic fields, both of which should be considered in epidemiological studies the possible adverse health effects use such devices. This paper describes a unique algorithm, developed for multinational case-control MOBI-Kids study, that estimates cumulative specific energy (CSE) induced current density (CICD) brain from RF ELF respectively, each...
Abstract Although radio frequency (RF) electromagnetic fields emitted by mobile phones have received much attention, relatively little is known about the extremely low (ELF) magnetic phones. This paper summarises ELF flux density measurements on global system for communications (GSM) phones, conducted as part of MOBI‐KIDS epidemiological study. The main challenge to identify a small number generic phone models that can be used classify exposure different reported in Two‐dimensional were...
The World Health Organization (WHO) is bringing together evidence on radiofrequency electromagnetic field (RF-EMF) exposure in relation to health outcomes, previously identified as priorities for evaluation by experts the field, inform guidelines. A suite of systematic reviews are being undertaken a network topic and methodologists order collect, assess synthesise data relevant these Here, we present protocol review effect RF adverse reproductive outcomes (human observational studies), also...
The Millimeter-Wave Bolometric Interferometer (MBI) is designed for sensitive measurements of the polarization cosmic microwave background (CMB). MBI combines differencing capabilities an interferometer with high sensitivity bolometers at millimeter wavelengths. It views sky directly through corrugated horn antennas low sidelobes and nearly symmetric beam patterns to avoid spurious instrumental from reflective optics. design first version instrument four 7-degree-FOV horns (MBI-4) discussed....
Myelofibrosis (MF) is a non-BCR-ABL myeloproliferative neoplasm associated with poor outcomes. Current treatment has little effect on the natural history of disease. MF results from complex interactions between (a) malignant clone, (b) an inflammatory context, and (c) remodeling bone marrow (BM) microenvironment. Each these points potential target PPARγ activation. Here, we demonstrated therapeutic agonists in resolving 3 mouse models. We showed that reduce myeloproliferation, modulate...
We present a new, fully-funded ground-based instrument designed to measure the B-mode polarization of Cosmic Microwave Background (CMB). The concept is based on three independent sub-systems operating at 90, 150 and 220 GHz, each comprising telescope focal plane horn-coupled background-limited bolometers. This highly-sensitive experiment, planned be Dome C station in Antarctica, optimised produce very low systematic effects. It will allow detection CMB over angular multipoles 20<l<1000...
Human exposure to electric and magnetic fields has been amply investigated in the extremely-low frequency (ELF) radiofrequency (RF) ranges. However, research on typical emissions intermediate-frequency (IF) range remains limited. In this study, an extensive measurement survey was performed levels of at intermediate frequencies typically emitted by a wide household appliances. The contained either harmonic signals, with fundamental between 6 kHz 100 kHz, or much more capricious spectra,...
Abstract Peptide vaccines have emerged as a promising strategy for cancer immunotherapy, yet often lack of strong, specific and sustained immune responses against tumor antigens. To achieve robust response, the effective selection tumour antigens is crucial. While neoantigens trigger potent responses, their use suffers from patient specificity rarity in low-mutational tumors. Alternatively, immunogenic potential tumor-associated (TAAs) limited by central tolerance. Molecular mimicry T cell...
Power density and duty factor values were measured around smart utility meters operating at 868 MHz under laboratory-controlled conditions. The maximum 6-min averaged exposure recorded was 0.1 mWm-2 , which is less than 0.0024% of the corresponding 1998 ICNIRP general public reference level. Duty factors 2.8%. This study found that contribution from Zigbee meter devices generally lower than, if not similar to, those 2.4 GHz. © 2023 Crown copyright. Bioelectromagnetics published by Wiley...