- Advanced Radiotherapy Techniques
- Radiation Therapy and Dosimetry
- Endometrial and Cervical Cancer Treatments
- Medical Imaging Techniques and Applications
- Management of metastatic bone disease
- Esophageal and GI Pathology
- Radiomics and Machine Learning in Medical Imaging
- Congenital Diaphragmatic Hernia Studies
- Intestinal Malrotation and Obstruction Disorders
- Hepatocellular Carcinoma Treatment and Prognosis
- Tracheal and airway disorders
- Lung Cancer Diagnosis and Treatment
- Advanced X-ray and CT Imaging
- Esophageal Cancer Research and Treatment
- Digital Radiography and Breast Imaging
- Urological Disorders and Treatments
- Radiation Detection and Scintillator Technologies
- Nuclear Physics and Applications
- Atomic and Subatomic Physics Research
- Pediatric Hepatobiliary Diseases and Treatments
- Nuclear reactor physics and engineering
- Uterine Myomas and Treatments
- Colorectal and Anal Carcinomas
- Advanced Biosensing Techniques and Applications
- Quantum, superfluid, helium dynamics
Sichuan Cancer Hospital
2016-2025
University of Electronic Science and Technology of China
2018-2025
Sichuan University
2011-2019
Zhengzhou University
2018-2019
Zhengzhou Children's Hospital
2013-2019
Key Laboratory of Nuclear Radiation and Nuclear Energy Technology
2018
The University of Texas MD Anderson Cancer Center
2017
Abstract Purpose and background The magnetic resonance (MR)‐only radiotherapy workflow is urged by the increasing use of MR image for identification delineation tumors, while a fast generation synthetic computer tomography (sCT) from dose calculation remains one key challenges to workflow. This study aimed develop neural network generate sCT in brain site evaluate dosimetry accuracy. Materials methods A generative adversarial (GAN) was developed translate T1‐weighted MRI sCT. First, "U‐net"...
The accuracy of dose calculation is crucial to the quality treatment planning and, consequently, delivered patients undergoing radiation therapy. Current general algorithms such as Pencil Beam Convolution (PBC) and Collapsed Cone (CCC) have shortcomings in regard severe inhomogeneities, particularly those regions where charged particle equilibrium does not hold. aim this study was evaluate PBC CCC lung cancer radiotherapy using Monte Carlo (MC) technology.Four plans were designed Oncentra...
Motivated by recent advances in deep learning, the purpose of this study was to investigate a learning method automatic segment and reconstruct applicators computed tomography (CT) images for cervix brachytherapy treatment planning.U-Net model developed applicator segmentation CT images. Sixty cervical cancer patients with Fletcher were divided into training data validation according ratio 50 : 10, another 10 employed test model. Dice similarity coefficient (DSC) 95th percentile Hausdorff...
ENWEndNote BIBJabRef, Mendeley RISPapers, Reference Manager, RefWorks, Zotero AMA Wang X, Li J, P, Yuan K, Yin G, Wan B. Image guided radiation therapy boost in combination with high-dose-rate intracavitary brachytherapy for the treatment of cervical cancer. Journal Contemporary Brachytherapy. 2016;8(2):122-127. doi:10.5114/jcb.2016.59282. APA Wang, X., Li, J., P., Yuan, K., Yin, G., & Wan, (2016). Brachytherapy, 8(2), 122-127. https://doi.org/10.5114/jcb.2016.59282 Chicago Xianliang, Jie...
Graphical optimization (GO) and inverse planning simulated annealing (IPSA) are the main treatment techniques used in patients undergoing 3D brachytherapy treatment. This study aims to compare dosimetric difference of plans optimized by GO IPSA cervical cancer brachytherapy.21 data sets consisted computed tomography (CT) magnetic resonance imaging (MRI), acquired with Fletcher applicator situ were transferred Oncentra system. For each patient, plan was initially reach a maximal D90 tumor...
A mini-ridge filter is often used to widen the Bragg peak in longitudinal direction at low energies but not high energies. To facilitate clinical use of a filter, we performed planning study for feasibility as an integral part synchrotron nozzle (IMRF). Dose models with and without IMRF were commissioned commercial Treatment system (TPS). Dosimetric characteristics homogenous water phantom compared between plans fixed spread-out width 4 cm distal ranges varying from 8 30 g/cm². Six cases...
ENWEndNote BIBJabRef, Mendeley RISPapers, Reference Manager, RefWorks, Zotero AMA Wang X, P, Li C, et al. An automated dose verification software for brachytherapy. Journal of Contemporary Brachytherapy. 2018;10(5):478-482. doi:10.5114/jcb.2018.79396. APA Wang, X., P., Li, C., Zhangwen, W., Chengjun, G., & J. (2018). Brachytherapy, 10(5), 478-482. https://doi.org/10.5114/jcb.2018.79396 Chicago Xianliang, Pei Churong Wu Gou Jie and Shengwei Kang 2018. "An brachytherapy". Brachytherapy 10 (5):...
To investigate an implementation method and the results of inverse dose optimization algorithm, Gradient Based Planning Optimization (GBPO), for three-dimensional brachytherapy.
Abstract In magnetic resonance- (MR-) based adaptive workflows for an MR-linac, the treatment plan is optimized and recalculated online using daily MR images. The Unity MR-linac supplied with a patient positioning device (ppd) pelvic abdomen thermoplastic masks attached to board high-density components. This study highlights dosimetric effect of this in such when there are relative patient-ppd displacements, as these not visualized on imaging planning system assumes fixed ppd. adapted plans...
<title>Abstract</title> Background: To investigate the impact of using contrast-enhanced computed tomography (CHCT) in dosimetry stereotactic body radiation therapy (SBRT) for liver metastases treated with MR-Linac. Methods: A retrospective study was conducted on 21 cancer patients SBRT (50Gy 5 fractions) a 1.5 Tesla Unity The clinical treatment plans optimised plain (pCT) were used as reference. electronic density (ED) regions interest (ROIs) including liver, duodenum, esophagus, spinal...
<title>Abstract</title> <bold>Background</bold> Magnetic resonance-guided adaptive radiotherapy (MRgART) at MR-Linac allows for plan optimisation on the MR-based synthetic CT (sCT) images, adjusting target and organs risk according to patient’s daily anatomy. Conversely, conventional linac image-guided (IGRT) involves rigid realignment of regions interest anatomy, followed by delivery reference computed tomography (CT) plan. This study aims evaluate effectiveness MRgART versus IGRT rectal...
Magnetic resonance-guided adaptive radiotherapy (MRgART) at MR-Linac allows for plan optimisation on the MR-based synthetic CT (sCT) images, adjusting target and organs risk according to patient's daily anatomy. Conversely, conventional linac image-guided (IGRT) involves rigid realignment of regions interest anatomy, followed by delivery reference computed tomography (CT) plan. This study aims evaluate effectiveness MRgART versus IGRT rectal cancer patients undergoing short-course...
To investigate the impact of using contrast-enhanced computed tomography (CHCT) in dosimetry stereotactic body radiation therapy (SBRT) for liver metastases treated with MR-Linac.
<title>Abstract</title> Background The aim of this study was to evaluate the inter-fraction reproducibility and intra-fraction stability breast radiotherapy using deep-inspiration breath hold (DIBH) free breathing (FB) based on an optical surface imaging system (OSIS). Methods Seventeen patients (510 breath-hold sessions) treated a field-in-field (FiF) technique twenty (600 breath-free with volume-modulated arc therapy (VMAT) were included in retrospective study. All positioned guidance CBCT...
The aim of this study was to evaluate the inter-fraction reproducibility and intra-fraction stability breast radiotherapy using voluntary deep-inspiration breath hold (DIBH) free breathing (FB) based on an optical surface imaging system (OSIS).
Given the significant therapeutic efficacy of anti-HER-2 treatment, HER-2 status is a crucial piece information that must be obtained in breast cancer patients. Currently, as per guidelines, typically acquired from tissue However, there growing interest obtaining serum and other samples due to convenience potential for dynamic monitoring. In this study, we have developed Raman spectroscopy technique allows rapid acquisition convenient manner. The established negative positive classification...
Abstract The halo portion of a proton therapy dose creates long tail in distributions, but so far study this phenomenon has been limited. We used statistical methods and mathematical models to confirm that the long-tailed distributions exhibits power-law relationship. By analyzing 299 measured profiles, we found all lateral had significant scaling correlation with high coefficient tail. set up dual-mechanism model, containing both direct indirect impact mechanisms. In mechanism, proximal...
Objective To simulate and calculate the dosimetric parameters of GZP 60Co source that has been clinically used in high-dose-rate brachytherapy. Methods The EGSnrc Monte Carlo software was to a well known BEBIG (Co0.A86). The results were compared with actual verify feasibility this method. A model for brachytherapy established its same way. Results For source, accorded standard. air-kerma strength per unit activity (SK/A) dose rate constant (Λ) deviated from standard by 0.2%...
Objective To investigate the Offset values of different applicators in afterloading brachytherapy. Methods Six types were selected this study which included stainless steel interstitial needle (Part#083.062), proguide round (Part#189.608), sharp (Part#189.601), vaginal multi-channel applicator (Part#110.800), fletcher CT/MR (Part#189.745) and henschke titanium (Part#110.437). According to sources imaging fluorography film, distance between first dwell position top could be measured....
To reduce the potential risk during radiotherapy treatment of patients with head and neck tumors, we improved upon design an existing immobilization device by adding a feature to improve patient safety emergency releases, verified its clinical application.We designed automatic unlocking baseplate (AUB), conducted dosimetry comparison Solo Align Full Body System (SAFBS, Klarity, China). The included dose-attenuation measurements results from human simulation. We selected four points for...
The automatic delineation of organs at risk (OARs) can help doctors make radiotherapy plans efficiently and accurately, effectively improve the accuracy therapeutic effect. Therefore, this study aims to propose an method for OARs in cervical cancer scenarios both after-loading external irradiation. At same time, similarity structure between different scenes is used segmentation difficult segmentations.