Matteo Ferrari

ORCID: 0000-0002-2447-9365
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Nuclear Physics and Applications
  • Radiation Detection and Scintillator Technologies
  • Radiation Therapy and Dosimetry
  • Nuclear Materials and Properties
  • Particle accelerators and beam dynamics
  • Fusion materials and technologies
  • Graphite, nuclear technology, radiation studies
  • Boron Compounds in Chemistry
  • Nuclear reactor physics and engineering
  • Superconducting Materials and Applications
  • Radiation Effects in Electronics
  • Particle Accelerators and Free-Electron Lasers
  • Luminescence Properties of Advanced Materials
  • Polymer Nanocomposite Synthesis and Irradiation
  • Radiation Shielding Materials Analysis
  • Advanced Radiotherapy Techniques
  • Metal and Thin Film Mechanics
  • Urologic and reproductive health conditions
  • Medical Imaging Techniques and Applications
  • Radiation Effects and Dosimetry
  • Polymer Nanocomposites and Properties
  • Sarcoma Diagnosis and Treatment
  • Radioactive Decay and Measurement Techniques
  • Tribology and Wear Analysis
  • Color Science and Applications

Laboratoire Hubert Curien
2022-2025

Centre National de la Recherche Scientifique
2022-2025

Université Jean Monnet
2022-2025

European Organization for Nuclear Research
2020-2023

University of Brescia
2015-2021

University of Parma
2021

Eindhoven University of Technology
2021

Istituto Nazionale di Fisica Nucleare, Sezione di Pavia
2015-2020

Ente Ospedaliero Cantonale
2019

National Interuniversity Consortium of Materials Science and Technology
2018

A new parasitic, mixed-field, neutron-dominated irradiation station has been recently commissioned at the European Laboratory for Particle Physics (CERN). The is installed in Neutron Time-Of-Flight (n\_TOF) facility, taking advantage of secondary radiation produced by neutron spallation target. allows damage studies to be performed conditions that are closer ones encountered during operation particle accelerators; tests carried out will complementary standard on materials, usually with gamma...

10.1103/physrevaccelbeams.25.103001 article EN cc-by Physical Review Accelerators and Beams 2022-10-20

The Isotope Separation On-Line (ISOL) method for the production of Radioactive Ion Beams (RIB) is attracting significant interest in worldwide nuclear physics community. Within this context SPES (Selective Production Exotic Species) RIB facility now under construction at INFN LNL (Istituto Nazionale di Fisica Nucleare Laboratori Nazionali Legnaro). This technique established as one main techniques high intensity and quality beams production. will produce n-rich isotopes by means a 40 MeV...

10.1088/1742-6596/966/1/012028 article EN Journal of Physics Conference Series 2018-02-01

Katritzky salts have emerged as effective alkyl radical sources upon metal- or photocatalysis. These are typically prepared from the corresponding triarylpyrylium ions, in turn an important class of photocatalysts for small molecules synthesis and photopolymerization. Here, a flow method rapid both pyrylium Katrizky telescoped fashion is reported. Moreover, several were tested photoinduced RAFT polymerization vinyl ethers under batch conditions.

10.1021/acs.orglett.1c00178 article EN cc-by-nc-nd Organic Letters 2021-03-02

Two 6-t beam dumps, made of a graphite core encapsulated in stainless steel vessel, are used to absorb the energy two Large Hadron Collider (LHC) intense proton beams during operation accelerator. Operational issues started appear 2015 LHC Run 2 (2014-2018) as consequence progressive increase kinetic energy, necessitating technical interventions highly radioactive areas around dumps. Nitrogen gas leaks appeared after energetic impacts and instrumentation measurements indicated an initially...

10.1088/1748-0221/16/11/p11019 article EN cc-by Journal of Instrumentation 2021-11-01

A characterization of radiophotoluminescence (RPL) dosimeters at high doses X-ray radiation for applications in areas is presented. Commercial FD-7 silver doped phosphate glasses (1.5 mm x 8.5 mm) use CERN passive dosimetry are irradiated using commercial tubes. 1.5 thick aluminium filter used to harden the spectrum and improve dose homogeneity. Two irradiation campaigns presented, targeting ranging from about 1.3 kGy 0.46 MGy rates 0.6 kGy/h 6.3 kGy/h, respectively. Monte Carlo simulations...

10.1109/tns.2024.3365272 article EN cc-by IEEE Transactions on Nuclear Science 2024-02-12

Radio Pharmaceutical Therapy (RPT) comes forth as a promising technique to treat wide range of tumors while ensuring low collateral damage nearby healthy tissues. This kind cancer therapy exploits the radiation following decay specific radionuclide deliver lethal dose tumor In framework ISOLPHARM project INFN, 111Ag was recently proposed core therapeutic radiopharmaceutical. this paper, production via neutron activation 110Pd-enriched samples inside TRIGA Mark II nuclear research reactor is...

10.1016/j.apradiso.2023.110798 article EN cc-by Applied Radiation and Isotopes 2023-03-30

Materials and components employed in the presence of intense neutron gamma fields are expected to absorb high dose levels that may induce deep modifications their physical mechanical properties, possibly causing loss function. A protocol for irradiating elastomeric materials reactor mixed testing evolution main properties with absorbed has been developed. Four compounds used vacuum O-rings, one fluoroelastomer polymer (FPM) based three ethylene propylene diene monomer rubber (EPDM) based,...

10.1063/1.5011035 article EN Review of Scientific Instruments 2017-11-01

Many of the moving components in accelerator and target environments require lubrication. Lubricants such are exposed to high fluxes secondary radiation, which originates from beam interactions with losses. The radiation is a mix components, can include significant fractions neutrons. radiation-sensitive polymeric materials. radiation-induced modifications their structure reduce service lifetime impose additional facility maintenance, complicated by environmental radioactivity. study...

10.1016/j.heliyon.2019.e02489 article EN cc-by-nc-nd Heliyon 2019-09-01

We discussed the X-rays permanent radiation effects on a variety of passive components developed using silicon photonics platform CEA-Leti. The objective is to assess vulnerability such devices at different total ionizing dose (TID) levels provide an overview main in this class components. In detail, we have irradiated room temperature grating couplers, microring resonators (MRRs), Mach–Zehnder interferometers (MZIs), Echelle de-multiplexers five doses, from 152 Gy(Si) 1.52 MGy(Si) with...

10.1109/tns.2023.3296985 article EN IEEE Transactions on Nuclear Science 2023-08-01

Samples of a commercially available polyphenyl ether (PPE) oil are irradiated in the mixed neutron and gamma radiation field Pavia TRIGA Mark II reactor, at irradiation doses ranging from 0.78 MGy to 7.8 MGy. The is nuclear grade product, whose resistance reported product specification based on cobalt-60 data. collection additional data reactor performed present work, motivated by need use this neutron-rich environments such as targets accelerators. post-irradiation characterization samples...

10.1016/j.nimb.2021.03.021 article EN cc-by Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms 2021-04-08

Radiophotoluminescence (RPL) FD-7 glass dosimeters find applications in low to high dose radiation environments. This work presents an experimental characterization of RPL dosimeter, irradiated with 100 kV X-ray tubes at room temperature doses ranging from 1.3 kGy 0.47 MGy, much higher their common use range. In this study, a customized set-up has been developed, allowing the online investigation transmission changes radiation, known as Radiation-Induced Attenuation (RIA), well recovery and...

10.1016/j.radmeas.2024.107246 article EN cc-by Radiation Measurements 2024-07-20

At the European Laboratory for Particle Physics (CERN), commercial greases and oils are extensively used to lubricate moving devices operating in high-radiation areas, absorbing doses up MGy range. Due their sensitivity radiation, lubricants can become fluid or solid operation, potentially causing component failures compromising operation of accelerator complex. CERN is therefore developing methodologies select radiation tolerant critical Beam Intercepting Devices (BIDs) such as high-power...

10.1016/j.nme.2021.101088 article EN cc-by Nuclear Materials and Energy 2021-11-28

Synovial sarcoma (SS) primarily occurs in the para-articular soft tissue of lower extremities young adults and it is extremely rare prostatic region. We report a case 46-year-old man who presented with urinary retention. Pelvic ultrasound (US) examination, computed tomography (CT), magnetic resonance imaging (MRI) demonstrated an 8.5 cm mass that appeared to originate fascia right lobe. Preoperative transrectal needle biopsy revealed mesenchymal neoplastic tissue. Patient underwent surgery....

10.1155/2015/419180 article EN cc-by Case Reports in Urology 2015-01-01

Irradiation tests are continuously needed at the European Organization for Nuclear Research (CERN), to experimentally assess radiation tolerance of commercial non-metallic materials use in high-radiation areas. The 'Radiation Materials' R2M activity organizes such and provides expertise interpretation results, design upgrade devices absorbing critical doses during their lifetime. various activities covered by presented. Up ten irradiation per year organized external <sup...

10.1109/tns.2023.3241785 article EN cc-by IEEE Transactions on Nuclear Science 2023-02-01

Elastomers are widely used in radioactive environments, where ionizing radiations induce a deterioration of their properties due to degradative phenomena occurring the polymer structure. Their radiation resistance is usually assessed using γ‐rays and relatively low dose rates, but actual applications, they often exposed mixed fields higher rates. Ethylene propylene diene monomer (EPDM) known for its excellent absorbs larger by neutron interactions than fluoroelastomer (FPM). In this work,...

10.1002/pen.25249 article EN Polymer Engineering and Science 2019-10-06
Coming Soon ...